Maintenance and Service GuideA–1 A Connector Pin Assignments Ta b l e A - 1 Stereo Speaker/Headphone Pin Signal Pin Signal 1 Audio out 2 Ground Ta b l e A - 2 Microphone Pin Signal Pin Signal 1 Audio in 2 Ground
A–2Maintenance and Service Guide Connector Pin Assignments Ta b l e A - 3 External Keyboard/Mouse Pin Signal Pin Signal 1 Keyboard/mouse data1 4 +5 VDC 2 Keyboard/mouse data2 5 Keyboard/mouse clock1 3 Ground 6 Keyboard/mouse clock2 KEY 6 54 32 1 Ta b l e A - 4 RJ-11 Modem Pin Signal Pin Signal 1Unused 4Unused 2 Tip 5 Unused 3Ring 6Unused
Connector Pin Assignments Maintenance and Service GuideA–3 Ta b l e A - 5 RJ-45 Network Interface Pin Signal Pin Signal 1 Transmit + 5 Unused 2 Transmit - 6 Receive - 3 Receive + 7 Unused 4Unused 8Unused 6 5 4 3 2 1 7 8 Ta b l e A - 6 Universal Serial Bus Pin Signal Pin Signal 1 +5VDC 3 Data+ 2 Data - 4 Ground
A–4Maintenance and Service Guide Connector Pin Assignments Ta b l e A - 7 Serial Pin Signal Pin Signal 1 Carrier detect 6 Data set ready 2 Receive data 7 Ready to send 3 Transmit data 8 Clear to send 4 Data terminal ready 9 Ring indicator 5 Signal ground 16 9 5
Connector Pin Assignments Maintenance and Service GuideA–5 Ta b l e A - 8 External Monitor Pin Signal Pin Signal 1 Red analog 9 +5 VDC 2 Green analog 10 Ground 3 Blue analog 11 Monitor detect 4 Not connected 12 DDC 2B data 5 Ground 13 Horizontal sync 6 Ground analog 14 Vertical sync 7 Ground analog 15 DDC2B clock 8Groundanalog 1 6115 1015
A–6Maintenance and Service Guide Connector Pin Assignments Ta b l e A - 9 Parallel Pin Signal Pin Signal 1 Strobe* 10 Acknowledge* 2 Data bit 0 11 Busy 3 Data bit 1 12 Paper out 4 Data bit 2 13 Select 5 Data bit 3 14 Auto line feed* 6 Data bit 4 15 Error* 7 Data bit 5 16 Initialize printer* 8 Data bit 6 17 Select in* 9 Data bit 7 18-25 Signal ground *Signal is active low. 114 25 13
Maintenance and Service GuideB–1 B Power Cord Set Requirements 3-Conductor Power Cord Set The computer’s wide range input feature permits it to operate from any line voltage from 100 to 120 or 220 to 240 volts AC. The power cord set received with the computer meets the requirements for use in the country where the equipment is purchased. Power cord sets for use in other countries must meet the requirements of the country where the computer is used. For more information on power cord set requirements, contact a Compaq authorized reseller or service provider. General Requirements The requirements listed below are applicable to all countries: The length of the power cord set must be at least 5.00 feet (1.5 m) and a maximum of 6.50 feet (2.0 m). All power cord sets must be approved by an acceptable accredited agency responsible for evaluation in the country where the power cord set will be used. The power cord set must have a minimum current capacity of 10A and a nominal voltage rating of 125 or 250 volts AC, as required by each country’s power system. The appliance coupler must meet the mechanical configuration of an EN 60 320/IEC 320 Standard Sheet C13 connector, for mating with appliance inlet on the back of the computer.
B–2Maintenance and Service Guide Power Cord Set Requirements Country-Specific Requirements Notes 1. The flexible cord must be Type HO5VV-F, 3-conductor, 1.0 mm2conductor size. Power cord set fittings (appliance coupler and wall plug) must bear the certification mark of the agency responsible for evaluation in the country whereitwillbeused. 3-Conductor Power Cord Set Requirements—By Country Country Accredited Agency Applicable Note Number Australia EANSW 1 Austria OVE 1 Belgium CEBC 1 Canada CSA 2 Denmark DEMKO 1 Finland FIMKO 1 France UTE 1 Germany VDE 1 Italy IMQ 1 Japan METI 3 The Netherlands KEMA 1 Norway NEMKO 1 Sweden SEMKO 1 Switzerland SEV 1 United Kingdom BSI 1 United States UL 2
Power Cord Set Requirements Maintenance and Service GuideB–3 2. The flexible cord must be Type SPT-3 or equivalent, No. 18 AWG, 3-conductor. The wall plug must be a two-pole grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V) configuration. 3. The appliance coupler, flexible cord, and wall plug must bear a “T” mark and registration number in accordance with the Japanese Dentori Law. The flexible cord must be Type VCT or VCTF, 3-conductor, 1.00mm 2conductor size. The wall plug must be a two-pole grounding type with a Japanese Industrial Standard C8303 (7A, 125V) configuration.
Maintenance and Service GuideC–1 C Screw Listing This appendix provides specification and reference information for the screws used in the computer. All screws listed in this appendix are available in the Miscellaneous Screw Kit, spare part number 239042-001.