Page 41

Be sure that all of the ground connections are without splices and are visible for inspection and
maintenance. Tag all of the ground connections with a sign that reads:Do Not Remove Or
Disconnect.
If you install expansion modules on the base cabinet, attach at least a #10 or #12 insulated, solid
copper wire between the frame ground stud on the expansion module(s) to the frame ground stud
on the base cabinet.
Remember, if spare conductors exist in the cables that run between the stations and the 66M-xx...

Page 42

2.4 Connecting The Lines
The line terminations for the common equipment cabinet are standard modular plug/jack
connections. Line configuration must be loopstart only. Each modular jack provides termination
for two lines. Modular line jacks 1 and 2 also provide termination for an auxiliary pair in
addition to the two outside lines. The outside line termination can be a type 66M-xx connector
block or individual 6-position modular jacks. The line cord that is routed between the outside
line termination and...

Page 43

Figure 2–5: Detailing The CO Line Interface
RING 2
RING 1
TIP 1
TIP 2
RING 4
RING 3
TIP 3
TIP 4
RING 6
RING 5
TIP 5
TIP 6
RING 8
RING 7
TIP 7
TIP 8CO/PBX
LINES
Line Terminations
Type 66M-XX
Connector Block
or
Individual 6-Position
Modular jacks
{
{
{
{
(Typical 8-Line, 16-Station
Base Unit Shown)
CAJS083
6-Wire Twisted
Pair Cable
6
5
4
3
2
1
No Conn.
Ring 2
Ring 1
Tip 1
Tip 2
No. Conn.
6
5
4
3
2
1
Aux. Ring
Ring 2
Ring 1
Tip 1
Tip 2
Aux. Tip
Pin designation for
Line Jacks 1 and 2Pin designation for
Line...

Page 44

2.4.1 Line Connection Details
The table on the next page shows the line connection details for all three of the common
equipment base units. Jacks one and two are the same for all three cabinets, jacks three and four
are the same for both the G0816 and G1632 cabinets, and jacks five through eight are only
available on the G1632 cabinet.
2.4.2 Reassigning The Line Ports
After you have initially connected a line to a particular line port and programmed its attributes
(or left it with the system defaulted...

Page 45

Table 2–2: Understanding the Line Connection Details
Common Equipment Type Line Jack Pin No. Connection Telephone Number
G0408,
G0816,
and
G163211 Auxiliary 1 (Line 2) Tip
2 Line 2 Tip
3 Line 1 Tip
4 Line 1 Ring
5 Line 2 Ring
6 Auxiliary 1 (Line 2) Ring
21 Auxiliary 2 (Line 4) Tip
2 Line 4 Tip
3 Line 3 Tip
4 Line 3 Ring
5 Line 4 Ring
6 Auxiliary 2 (Line 4) Ring
G0816
and
G163231 No Connection
2 Line 6 Tip
3 Line 5 Tip
4 Line 5 Ring
5 Line 6 Ring
6 No Connection
41 No Connection
2 Line 8 Tip
3 Line 7 Tip...

Page 46

2.5 Connecting The Stations
The digital telephone system supports the operation of proprietary Comdial telephones.
The G0408, G0816 and G1632 common equipment supports the installation of up to eight, 16,
or 32 telephones, respectively. Add-on expansion modules are available to expand the station
capacity of the systems. One 4-line 8-station expansion module can be added to the G0408. The
G0816 and G1632 can each take two expansion modules.
Connections between the common equipment and the stations are...

Page 47

2.5.1 Grounding The Stations
Remember, if spare conductors exist in the cables that run between the stations and the 66M-xx
connector blocks, it is good practice to connect them to earth ground. Doing this may help
prevent them from introducing radio frequency and/or AC interference into the system. Also
remember that it is good practice to disconnect any unused station jacks from the connector
block and ground that wiring to earth ground as well.
Remove insulation and twist together all spare wires at...

Page 48

Figure 2–6: Station Connections
16-Line, 32-Station Base Unit
Stations 10-25
Stations 26-41Power Fail Station
Grounding
Terminal
4-Line, 8-Station Base Unit
Station 10-17, 
Power Fail Station
Grounding
Terminal
Station 10-25
Power Fail Station Grounding
Terminal
8-Line, 16-Station Base Unit
CAJS084
Digital Telephone SystemIMI66–107
2 – 18 Installing The DSU 

Page 49

2.5.4 Connecting Stations To The G0408
This table shows the color-coded connections for a G0408 common equipment cabinet.
Table 2–3: Connecting Stations To The G0408 Common Equipment Cabinet
25-Pair Connections Two-Wire Connections Station Connections
Wire Color Pair Pin No.Clip
Term.Pair Wire Color Station Location
White-Blue
126 1
Signal PathGreen
10
Blue-White 1 2 Red
White-Orange
227 3
Signal PathGreen
11
Orange-White 2 4 Red
White-Green
328 5
Signal PathGreen
12
Green-White 3 6 Red
White-Brown
429...

Page 50

2.5.5 Connecting Stations To The G0816
This table shows the color-coded connections for a G0816 common equipment cabinet.
Table 2–4: Connecting Stations To The G0816 Common Equipment Cabinet
25-Pair Connections Two-Wire Connections Station Connections
Wire Color Pair Pin No.Clip
Term.Pair Wire Color Station Location
White-Blue
126 1
Signal PathGreen
10
Blue-White 1 2 Red
White-Orange
227 3
Signal PathGreen
11
Orange-White 2 4 Red
White-Green
328 5
Signal PathGreen
12
Green-White 3 6 Red
White-Brown
429...