Page 41
Be sure that all of the ground connections are without splices and are visible for inspection and maintenance. Tag all of the ground connections with a sign that reads:Do Not Remove Or Disconnect. If you install expansion modules on the base cabinet, attach at least a #10 or #12 insulated, solid copper wire between the frame ground stud on the expansion module(s) to the frame ground stud on the base cabinet. Remember, if spare conductors exist in the cables that run between the stations and the 66M-xx...
Page 42
2.4 Connecting The Lines The line terminations for the common equipment cabinet are standard modular plug/jack connections. Line configuration must be loopstart only. Each modular jack provides termination for two lines. Modular line jacks 1 and 2 also provide termination for an auxiliary pair in addition to the two outside lines. The outside line termination can be a type 66M-xx connector block or individual 6-position modular jacks. The line cord that is routed between the outside line termination and...
Page 43
Figure 2–5: Detailing The CO Line Interface RING 2 RING 1 TIP 1 TIP 2 RING 4 RING 3 TIP 3 TIP 4 RING 6 RING 5 TIP 5 TIP 6 RING 8 RING 7 TIP 7 TIP 8CO/PBX LINES Line Terminations Type 66M-XX Connector Block or Individual 6-Position Modular jacks { { { { (Typical 8-Line, 16-Station Base Unit Shown) CAJS083 6-Wire Twisted Pair Cable 6 5 4 3 2 1 No Conn. Ring 2 Ring 1 Tip 1 Tip 2 No. Conn. 6 5 4 3 2 1 Aux. Ring Ring 2 Ring 1 Tip 1 Tip 2 Aux. Tip Pin designation for Line Jacks 1 and 2Pin designation for Line...
Page 44
2.4.1 Line Connection Details The table on the next page shows the line connection details for all three of the common equipment base units. Jacks one and two are the same for all three cabinets, jacks three and four are the same for both the G0816 and G1632 cabinets, and jacks five through eight are only available on the G1632 cabinet. 2.4.2 Reassigning The Line Ports After you have initially connected a line to a particular line port and programmed its attributes (or left it with the system defaulted...
Page 45
Table 2–2: Understanding the Line Connection Details Common Equipment Type Line Jack Pin No. Connection Telephone Number G0408, G0816, and G163211 Auxiliary 1 (Line 2) Tip 2 Line 2 Tip 3 Line 1 Tip 4 Line 1 Ring 5 Line 2 Ring 6 Auxiliary 1 (Line 2) Ring 21 Auxiliary 2 (Line 4) Tip 2 Line 4 Tip 3 Line 3 Tip 4 Line 3 Ring 5 Line 4 Ring 6 Auxiliary 2 (Line 4) Ring G0816 and G163231 No Connection 2 Line 6 Tip 3 Line 5 Tip 4 Line 5 Ring 5 Line 6 Ring 6 No Connection 41 No Connection 2 Line 8 Tip 3 Line 7 Tip...
Page 46
2.5 Connecting The Stations The digital telephone system supports the operation of proprietary Comdial telephones. The G0408, G0816 and G1632 common equipment supports the installation of up to eight, 16, or 32 telephones, respectively. Add-on expansion modules are available to expand the station capacity of the systems. One 4-line 8-station expansion module can be added to the G0408. The G0816 and G1632 can each take two expansion modules. Connections between the common equipment and the stations are...
Page 47
2.5.1 Grounding The Stations Remember, if spare conductors exist in the cables that run between the stations and the 66M-xx connector blocks, it is good practice to connect them to earth ground. Doing this may help prevent them from introducing radio frequency and/or AC interference into the system. Also remember that it is good practice to disconnect any unused station jacks from the connector block and ground that wiring to earth ground as well. Remove insulation and twist together all spare wires at...
Page 48
Figure 2–6: Station Connections 16-Line, 32-Station Base Unit Stations 10-25 Stations 26-41Power Fail Station Grounding Terminal 4-Line, 8-Station Base Unit Station 10-17, Power Fail Station Grounding Terminal Station 10-25 Power Fail Station Grounding Terminal 8-Line, 16-Station Base Unit CAJS084 Digital Telephone SystemIMI66–107 2 – 18 Installing The DSU
Page 49
2.5.4 Connecting Stations To The G0408 This table shows the color-coded connections for a G0408 common equipment cabinet. Table 2–3: Connecting Stations To The G0408 Common Equipment Cabinet 25-Pair Connections Two-Wire Connections Station Connections Wire Color Pair Pin No.Clip Term.Pair Wire Color Station Location White-Blue 126 1 Signal PathGreen 10 Blue-White 1 2 Red White-Orange 227 3 Signal PathGreen 11 Orange-White 2 4 Red White-Green 328 5 Signal PathGreen 12 Green-White 3 6 Red White-Brown 429...
Page 50
2.5.5 Connecting Stations To The G0816 This table shows the color-coded connections for a G0816 common equipment cabinet. Table 2–4: Connecting Stations To The G0816 Common Equipment Cabinet 25-Pair Connections Two-Wire Connections Station Connections Wire Color Pair Pin No.Clip Term.Pair Wire Color Station Location White-Blue 126 1 Signal PathGreen 10 Blue-White 1 2 Red White-Orange 227 3 Signal PathGreen 11 Orange-White 2 4 Red White-Green 328 5 Signal PathGreen 12 Green-White 3 6 Red White-Brown 429...