Page 251
4. Identify the expansion cabinet slots where you will install the DXPT1 boards and the primary and secondary (if available) CO line supplier. With this knowledge, designate one DXPT1 board as primary and another DXPT1 board as secondary by placing straps on the services board and setting DIP switches on the expansion cabinet interface board. (a)If you install one DXPT1 board in an expansion cabinet, you must strap one pin-pair (J–M) on the services board’s PRIMARY strap block. This strap designates the...
Page 252
Services Board Primary Clock Strapping Block Strapping Pairs A B C D E F G H I J K L M Secondary Clock Strapping Block PLUS009 J6 J7 Upper Cabinet Lower Cabinet Locating The Services Board Strapping Blocks IMI89–193 Installing The DXPT1 Line Board 22 – Installing The DXPT1 Line Board
Page 253
Open OpenClosed Closed Switch A Expansion Cabinet Slot Locations Switch B Expansion Cabinet Slot Locations Expansion Cabinet Interface Board 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 89 10 11 12 9 10 11 12 PLUS010 SWA SWB Note:SWA-12 and SWB-12 are not used on Interface 2 (upper cabinet). SWA-11/12 and SWB-11/12 are not used on Interface 3 (lower cabinet).SWA and SWB switches not in use must be in off (open) position! Locating The Interface Board DIP Switches Installing The DXPT1 Line Board IMI89–193 Installing The...
Page 254
5.2 Installing The Services Board Assembly 1. With your static discharge wrist strap still properly installed, install the services board in the main cabinet. 2. If the installation includes a DXOPT–SYN card, make sure the lower (larger) slide switch on the front edge of the card is in the upAUTOposition. Leave the upper (smaller) switch in either position as it has no effect when the automatic mode is selected. 3. Orient the services board assembly with its top and bottom guides in main cabinet board...
Page 255
Static Discharge Wrist Strap PRI LED SEC LED AUTO MANUAL SWITCH (Set to AUTO Position) Services Board PAGE BGM MOH RELAY 1 RELAY 2 RELAY 3 RELAY 4 COMDIAL OPBD3 OUTMAIN CABINET BATTERYOPBD2 ON =OK STATUSOPBD1 PLUS006 PRI PRISEC SEC UNLOCKED SOURCEDXOPT SYN MODE MANUAL AUTOMAN Installing The Services Board Assembly Installing The DXPT1 Line Board IMI89–193 Installing The DXPT1 Line Board – 25
Page 256
6.0 Understanding The T1 Alarms And Indicators Most of the T1 alarms and indicators (LEDs) are located on the front-edge panel of the DXPT1 board, while several are located on the front edge of the DXOPT-SYN card. The following sections discuss the alarms and indicators. NOTE:Red /Yellow LEDs, when lit, indicate errors or non-standard configuration for normal operation. Red Alarm (red LED)When this LED indicator is lit, the system cannot establish communications with the network. Yellow Alarm (yellow...
Page 257
Cyclic Redundancy Check (red LED)When using the ESF format, the cyclic redundancy check (CRC) indicator lights whenever there is a discrepancy in the check sum received for an incoming frame from the originating system and the locally calculated check sum. This discrepancy indicates a data error in the received frame. The CRC is enabled by DIP switch SW2-4. Slip (red LED)This indicator is turned on whenever a frame slip is detected. This is caused by the transmit clock not being synchronized with the...
Page 258
6.1 Viewing The DXPT1 Board Alarms And Indicators LED*LABELERROR OR STATUS CONDITION WHEN LED IS LIT l(Status) Rapid flash = defective board Steady on = board in wrong slot or board constraints violated Off with repeated five second blink on = normal operation (T1 trunk idle) On with repeated five second blink off = normal operation (T1 trunk busy) lRed Communications with network cannot be established (out-of-service) ¤Yellow Disruption in remote T1 service lSync Loss of sync with the incoming signal...
Page 259
Services Board Status Red Yellow Sync Signal Blue Bipolar CRC Slip Unlock B8ZS/COFA Remote Loopback Local Loopback Payload Loopback Primary Secondary Unlocked Status Manual DXOPT-SYN Card Diagnostic Switches and LEDs for Factory Use OnlyDXPT1 Board PLUS007 Viewing DXPT1 And DXOPT–SYN Alarms And Indicators Installing The DXPT1 Line Board IMI89–193 Installing The DXPT1 Line Board – 29
Page 260
7.0 Understanding Installer/User Information Regarding FCC Rules and Regulations This electronic key system complies with Federal Communications Commission (FCC) Rules, Part 68. The FCC registration label on the DXP Plus contains the FCC registration number, the ringer equivalence number, the model number, and the serial number or production date of the system. 7.1 Notification To Telephone Company Unless a telephone operating company provides and installs the system, the telephone operating company...