Page 11
2.4 Using Impact Telephones The DXPPlusaccepts all of the currently producedImpacttelephones. Figure 3 details all of theImpact telephones that operate on the DXPPlus. Figure 4 shows the dimensions of theImpactMultiline telephone. QZ ABC DEF MNO WXY GHI PRSTUV OPER JKL TRNS/CNF HOLDTAP INTERCOM QZ ABC DEF MNO WXY GHI PRSTUV OPER JKL TRNS/CNF HOLDTAP INTERCOM MUTE SHIFTSPEAKERINTERCOMTRNS/CNFTAP HOLD OPERTUV PRS WXYDEF ABC QZ MNO JKL GHI# MUTE SHIFTSPEAKERINTERCOMTRNS/CNFTAP HOLD OPERTUV PRS WXYDEF ABC...
Page 12
8012S, 8112S8101N, 8112N 8024S, 8124S 4.640 10.750 9.0807.130 8.9008.900 3.731 1.034 8.900 CAJS077 Figure 4:ImpactStation Outline Dimensions DXP Plus General Description GCA40–130 Telephone Features – 9
Page 13
2.5 Using ExecuTech Telephones The DXPPlusaccepts all of the currently produced ExecuTech telephones. Figure 5 details all of the ExecuTech telephones that operate on the DXPPlus. Figure 6 shows the dimensions of the ExecuTech Multiline telephone. TAP MUTE SPKR HOLD ITCMTRANS CONFABC GHI PRS SYSJKL TUV OPERMNO WXY RDL DEF 6620T 6620E HOLDSPKR MUTETA P TRANS CONF SHIFT MW I TCM ABC JKL TUV OPER GH I PRS SYSDEF MNO WXY RDL 6614T 6614E TAP MUTE SPKR HOLD ITCMTRANS CONFABCGHIPRSSYS JKLTUVOPER MNOWXYRDL DEF...
Page 14
Figure 6: ExecuTech Station Outline Dimensions 8.625 6.451 7.658 8.6254.983 4.069 1.112 1.251 2.887 4.007 CAJS045 DXP Plus General Description GCA40–130 Telephone Features – 11
Page 15
Reviewing The Hardware 3.1 Understanding The Printed-Wire Boards The basic system consists of a main cabinet, which accepts 14 printed-wire boards, and two expansion cabinets; the upper expansion cabinet accepts twelve printed-wire boards, and the lower cabinet accepts eleven (see Figure 7). Some of the printed-wire boards also hold smaller circuit cards that mount directly to the boards (See section 3.5 for card information) The line boards are listed in section 3.3; station boards are located in...
Page 16
3.2 Defining The Line Boards The DXPPlusaccepts several different types of lines. In order to use these various lines, you must install the correct line board. The following list details all of the current DXPPlusline boards. Direct Inward Dialing Line Board: —Direct Inward Lines (DID) are incoming only and are employed to reduce the number of channels between the DXPPlusand the Central Office (CO). DID lines allow incoming CO calls to reach internal intercom extensions without going through the...
Page 17
3.3 Defining The Station Boards The DXPPlusaccepts digital, analog, and industry standard telephones. In order to use these different types of stations, you must install the correct station board. The following list explains each station board. Analog Station Board —The analog station board provides support for Comdial’s proprietary analog telephones (such as the various ExecuTech models). Each board supports either 8 or 16 stations. A precharge port is provided for board removal or insertion without...
Page 18
3.4 Defining The Option Circuit Cards Many of the DXPPlusboards accept smaller circuit cards. These boards mount directly into the DXP Plus, while the optional circuit cards mount only onto boards. You can install these optional cards on any of the following boards: the Auxiliary Board, the Services board, and the Interface boards. Synchronization Card —Adjusts the E1 or T1 transmit frequency to match the frequency from the CO. The synchronization card mounts onto the Services board only. Communications...
Page 19
3.5 Locating The Boards Main Cabinet The 14-board capacity of the main cabinet breaks down as follows from left to right: 1 – interface board slot 2 – board slots for future features) 1 – CPU board slot 1 – services board slot 1 – auxiliary/universal slot (for auxiliary boards, station boards, conference boards, or line boards) 8 – universal slots (for station, conference, or line boards) Upper Expansion Cabinet The 12-board capacity of the upper expansion cabinet breaks down as follows: 1 – interface...
Page 20
PLUS067A 1 Interface Slot 2 Aux./ Universal Slots 9 Universal Slots 1 Interface Slot 1 CPU Slot 1 Services Slot 1 Aux./ Universal Slot 8 Universal Slots 1 Interface Slot 2 Aux./ Universal Slots 8 Universal Slots Main Cabinet Lower Expansion Cabinet Upper Expansion Cabinet Figure 7: Board Locations DXP Plus General Description GCA40–130 Reviewing The Hardware – 17