Comdial Dsu II Installation Manual
Here you can view all the pages of manual Comdial Dsu II Installation Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 1
Installing The DSU II Digital Telephone System SectionTitle ...........................................................................................................Page 2.1 Considering the Mounting Requirements................................................2–4 2.1.1 Tools And Hardware ..............................................................................2–5 2.1.2 Underwriters Laboratories Installation Notice .......................................2–5 2.1.3 Hybrid Installation...
Page 2
SectionTitle ...........................................................................................................Page 2.6 Installing DSS/BLF Consoles ..................................................................2–26 2.7 Connecting A Power Failure Station......................................................2–28 2.8 Using The Auxiliary Equipment Interface ............................................2–29 2.9 Common The Audible And Auxiliary Ringing Interface .....................2–30 2.9.1...
Page 3
SectionTitle ...........................................................................................................Page 2.16 Isolating Failures ......................................................................................2–51 2.16.1 Checking The System Status Indicator .................................................2–51 2.16.2 Testing The Stations .............................................................................2–51 2.17 Loading And Up-Grading The System Software...
Page 4
2.1 Considering The Mounting Requirements The following requirements will help you to install the DSU II digital telephone system. ·Locate the equipment cabinet within four feet of an AC electrical outlet dedicated exclusively to the use of this equipment. The outlet must be a 117 VAC 15 AMP circuit with a third-wire ground supplied to a standard electrical outlet (NEMA 5–15R). ·Mount the common equipment within 25 feet of the TELCO/PBX jacks. The recommended nominal distance is 7 feet. ·Choose a secure...
Page 5
2.1.1 Tools And Hardware You will need the following tools and materials to install the common equipment. ·Fasteners—wood screws (1/4 x 1-inch round head), toggle bolts, or wall anchors, ·Screwdriver—to match fasteners, ·Electric drill—if prepared holes are required, ·Connecting tool—for fastening wires to a type-66 connector block, ·Crimping tool—for 623-type modular plugs, ·Volt/Ohm Meter. 2.1.2 Underwriters Laboratories Installation Notice Per The Underwriters Laboratories standard 1459, 2nd edition,...
Page 6
2.2 Mounting The Cabinet After thoroughly reviewing Section 2.1 and fully understanding its subject matter, use the following procedure to mount the common equipment cabinet 1. Unpack and carefully inspect all equipment for shipping damage. Notify the shipper immediately of any damages that you find. Verify that the packages contain all parts and accessories needed for proper installation and operation. 2. If the mounting location requires a backboard, attach it securely to provide a stable mounting...
Page 7
DSU250.CDR 4.54 3.78 3.78 16.50 16.50 16.50 27.58 27.5821.30 0.88 0.87 26.65 26.25 20.50 Back of 16-Line, 32-Station Base UnitBack of 8-Line, 16-Station Base Unit Back of 4-Line, 8-Station Base Unit 4-Line, 8-Station Base Unit 8-Line, 16-Station Base Unit 16-Line, 32-Station Base Unit 0.88 Detailing The DSU II Cabinet Dimensions DSU II Digital Telephone System IMI66–132 Installing The DSU II Digital Telephone System 2 – 7
Page 8
2.3 Making The AC Power Connection You must employ a dedicated 117VAC 15 AMP circuit, with a third-wire ground, supplied to a standard electrical outlet (NEMA 5-15R) for the AC power connection. ·For added equipment protection, connect a plug-in power line surge protector between the power cord and the AC outlet. ·Thoroughly check out the installation before connecting the power cord to an electrical outlet to apply AC power to the system. 2.3.1 Identifying The Fuses The system is protected against short...
Page 9
Typical earth groundGrounding terminalPlug-in power line surge protector (typical) Dedicated 117VAC 15 AMP NEMA 5-15R electrical outlet with third-wire ground Fuse (See text) DSU211 Making The AC Power Connections DSU II Digital Telephone System IMI66–132 Installing The DSU II Digital Telephone System 2 – 9
Page 10
2.3.2 Grounding The System If spare conductors exist in the cables between the station and the 66M-xx connector blocks, it is good practice to connect them to an earth ground. Doing this may help prevent them from inducing radio frequency and/or AC interference into the system. It is also good practice to disconnect any unused station jacks from the connector block and ground that wiring to an earth ground as well. Transient voltage spikes, if induced onto CO or CENTREX lines, can travel through the...