Page 101
Installing An OPX Long Loop Adapter To The Analog Terminal Interface For Off-Premise Service As stated previously, the analog terminal interface is an on-premise device. You must use an OPX long loop adapter if you wish to adapt the ATI-D to support an off-premise application. An OPX long loop adapter connects to a single telephone line and can greatly extend the line’s loop length (the Proctor Model 46222 adapter*, for example, can extend line length to 30,000 feet). *Proctor & Associates Company,...
Page 102
Earth Ground (Optional) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 CLIP TERMINALS 50 26 1 25 Typical Station Connector Block ATI-D Common Equipment Jack IST Jack Off-Premise IST Jack OPX Long Loop AdapterOn-Premise IST Jack Connect to station connector jack on common equipment. CAJS106 11 7 VA C 4 43 32 25 5 Installing The Long Loop Adapter DSU II Digital Telephone System IMI66–132 Installing The DSU II...
Page 103
2.18.3 Installing The Data Interface Unit Unpack the Data Interface Unit (DIU) and check for the following parts: ·Telephone line cord ·Power cable with attached transformer. Installing The Mechanical Components You can install the DIU in either a free-standing manner or you can mount it on a wall. When mounting the DIU on a wall: 1. Select a location that is close to a standard 115 VAC electrical wall outlet. The location you select should also be convenient to the digital telephone and the Industry...
Page 104
3. Install two #8 X 3/4-inch screws in the wall at the locations you marked in step 2. Tighten the screws until the screw heads are 1/4-inch from the surface of the wall. 4. Place the DIU on the wall with the screw heads inserted into the slots provided on the bottom surface of the DIU. Slide the DIU onto the screw heads until it is firmly attached to the screws. Installing The DIU Mounting Screws DSU II Digital Telephone System IMI66–132 Installing The DSU II Digital Telephone System 2 – 73
Page 105
Making The Data Interface Unit Cable Connections Four cable connections are required to the DIU-station line cord, digital telephone line cord, IST/FAX/MODEM line cord, and power cable. 1. Disconnect the line cord on the digital telephone from the digital station port connector and plug it into the connector labeled PHONE on the DIU. 2. Plug the line cord from the IST device you are installing with the DIU (such as a FAX machine, or modem) into the DIU connector labeled FAX/MODEM. 3. Plug the transformer...
Page 106
Typical Multiline Digital Telephone ( Model 8012S Illustrated)Impact To KSU Station Port Making The DIU Cable Connections DSU II Digital Telephone System IMI66–132 Installing The DSU II Digital Telephone System 2 – 75
Page 107
2.18.4 Supporting Caller Identification Service You can provide Caller ID information through the serial data port COM2 using the Caller ID Interface (product code CID08) and a special equipment-supplied cable. Caller ID information for incoming calls shows on the displays of the system’s LCD speakerphones. Make the connections that are detailed in the following statements. ·Connect the CO lines providing Caller ID data to both the common equipment and the CID08 line jacks in the same numerical order....
Page 108
PORTS 1 2 3 4 5 6 7 8POWERRS-232 OUTRS-232 IN Modular Line Jacks Power Supply Connector Serial Data Connectors Locating The CID08 Connectors P O R T S RS-232 In CID08 Unit #1 RS-232 Out Lines 1-8 P O R T S RS-232 In CID08 Unit #2 RS-232 Out Lines 9-16 P O R T S RS-232 In CID08 Unit #3 RS-232 Out Lines 17-24 To Either COM2 Serial Data Port or To Next CID08 Unit Combining Multiple CID08 Units CTS (Pin 2) RD (Pin 3) (Pin 5) SG (Pin 4) TD 95 84 73 62 1 From Caller ID Unit RS-232 OUT Male 9-Pin, D-sub Solder...
Page 109
Setting The Caller ID Parameter Switches The Caller ID device has two banks of parameter switches located on its front panel. Set the switches of the S1 switch bank per the following rule: ·If you are combining units (more than 8 lines are used), turn all switches in Dip Switch S1 OFFexcept for switch 7. Turn S1 switch 7ONwhen combining units. If you are not combining units, turn all S1 switchesOFF. You must set the switches of the S2 switch bank in a certain manner to enable Caller ID operation....
Page 110
Power LED Data LED Dip Switch 2 (Switches 1-8) Dip Switch 1 (Switches 1-8) PWRDATA Caller ID S1 S2 CAJS092 LocatingThe CID08 DIP Switches DSU II Digital Telephone System IMI66–132 Installing The DSU II Digital Telephone System 2 – 79