A-7 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix A Technical Specifications Power Requirements DC input voltage –36 to –72 VDC 3 to 1.5 A Power consumption 94 W, 321 BTUs per hour Physical Dimensions Weight 9 lb (4.1 kg) Dimensions (H x W x D) 1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm) Table A-13 Specifications for the Catalyst 3560V2-24TS-SD Switch (continued) Environmental Ranges
A-8 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix A Technical Specifications
B-1 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 APPENDIXB Connector and Cable Specifications This appendix describes the Catalyst 3560 switch ports and the cables and adapters that you use to connect the switch to other devices and includes these sections: “Connector Specifications” section on page B-1 “Cable and Adapter Specifications” section on page B-4 Connector Specifications 10/100 and 10/100/1000 Ports, page B-1 SFP Module Ports, page B-2 Dual-Purpose Ports, page B-3 Console Port, page B-3 10/100 and 10/100/1000 Ports The 10/100 and 10/100/1000 Ethernet ports use standard RJ-45 connectors and Ethernet pinouts with internal crossovers. These ports have the send (TD) and receive (RD) signals internally crossed so that a twisted-pair straight-through cable and adapter can be attached to the port. Figure B-1 shows the pinout for a 10/100 port.
B-2 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Connector Specifications Figure B-1 10/100 Port Pinouts Figure B-2 shows the pinout for a 10/100/1000 port. Figure B-2 10/100/1000 Port Pinouts SFP Module Ports The Catalyst 3560 switch uses SFP modules for fiber-optic and copper uplinks. See the Catalyst 3560 release notes for a list of supported SFP modules. Figure B-3 Fiber-Optic SFP Module LC Connector H5318 23 1 45678Pin Label 1 2 3 4 5 6 7 8RD+ RD- TD+ NC NC TD- NC NC 60915 23 1 45678Pin Label 1 2 3 4 5 6 7 8TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3- 58476
B-3 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Connector Specifications Figure B-4 Copper SFP Module RJ-45 Connector Dual-Purpose Ports The Ethernet port on a dual-purpose port uses standard RJ-45 connectors. Figure B-5 shows the pinouts. Figure B-5 10/100/1000 Port Pinouts The SFP module slot on a dual-purpose port uses SFP modules for fiber-optic and copper uplink ports. See the Catalyst 3560 release notes for a list of supported SFP modules. NoteThe auto-MDIX feature is enabled by default. For configuration information for this feature, see the switch software configuration guide or the switch command reference. Console Port The console port uses an 8-pin RJ-45 connector, described in Ta b l e B - 2 and Ta b l e B - 3. The RJ-45-to-DB-9 adapter cable connects the console port of the switch to a console PC. You need an RJ-45-to-DB-25 female DTE adapter (ACS-DSBUASYN=) to connect the switch console port to a terminal. For console port and adapter pinout information, see Ta b l e B - 2 and Ta b l e B - 3. 60915 23 1 45678Pin Label 1 2 3 4 5 6 7 8TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3- 60915 23 1 45678Pin Label 1 2 3 4 5 6 7 8TP0+ TP0- TP1+ TP2+ TP2- TP1- TP3+ TP3-
B-4 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Cable and Adapter Specifications SFP Module Cable Specifications, page B-4 Two Twisted-Pair Cable Pinouts, page B-5 Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports, page B-6 Identifying a Crossover Cable, page B-6 Adapter Pinouts, page B-7 SFP Module Cable Specifications Ta b l e B - 1 lists the cable specifications for the fiber-optic SFP module connections. Each port must match the wave-length specifications on the other end of the cable, and for reliable communications, the cable must not exceed the required cable length. Copper 1000BASE-T SFP transceivers use standard four twisted-pair, Category 5 or greater cable at lengths up to 328 feet (100 meters). Table B-1 Fiber-Optic SFP Module Port Cabling Specifications SFP ModuleWavelength (nanometers) Fiber TypeCore Size/Cladding Size (micron)Modal Bandwidth (MHz/km)1Cable Distance 100BASE-BX (GLC-FE-100BX-D GLC-FE-100BX-U)1310 TX 1550 RXSMF G.652 2— 32,810 feet (10 km) 100BASE-FX (GLC-GE-100FX)1310 MMF 50/125 62.5/125500 5006,562 feet (2 km) 6,562 feet (2 km) 100BASE-FX (GLC-FE-100FX)1310 MMF 50/125 62.5/125500 5006,562 feet (2 km) 6,562 feet (2 km) 100BASE-LX (GLC-FE-100LX)1310 SMF G.652 2— 32,810 feet (10 km) 1000BASE-BX10-D (GLC-BX-D)1490 TX 1310 RXSMF G.652 2— 32,810 feet (10 km) 1000BASE-BX10-U (GLC-BX-U)1310 TX 1490 RXSMF G.652 2— 32,810 feet (10 km) 1000BASE-SX (GLC-SX-MM)850 MMF 62.5/125 62.5/125 50/125 50/125160 200 400 500722 feet (220 m) 902 feet (275 m) 1640 feet (500 m) 1804 feet (550 m) 1000BASE-LX/LH (GLC-LH-SM)1310 MMF 3 SMF62.5/125 50/125 50/125 G.652 2 500 400 500 —1804 feet (550 m) 1804 feet (550 m) 1804 feet (550 m) 32,810 feet (10 km) 1000BASE-ZX (GLC-ZX-SM1550 SMF G.652 2— 43.4 to 62 miles (70 to 100 km)4
B-5 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Two Twisted-Pair Cable Pinouts Figure B-6 and Figure B-7 show the schematics of two twisted-pair cables for connecting to 10BASE-T- and 100BASE-TX-compatible devices. Figure B-6 Two Twisted-Pair Straight-Through Cable Schematic Figure B-7 Two Twisted-Pair Crossover Cable Schematic CWDM 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 SMF G.6522— 62 miles (100 km) DWDM ITU channels 21-59 —— — — 1. Modal bandwidth applies only to multimode fiber. 2. A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers 3. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m). 4. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors. Table B-1 Fiber-Optic SFP Module Port Cabling Specifications (continued) SFP ModuleWavelength (nanometers) Fiber TypeCore Size/Cladding Size (micron)Modal Bandwidth (MHz/km)1Cable Distance Switch 3 TD+ 6 TD– 1 RD+ 2 RD– Router or PC 3 RD+ 6 RD– 1 TD+ 2 TD– H5578 Switch 3 TD+ 6 TD– 1 RD+ 2 RD– Switch 3 TD+ 6 TD– 1 RD+ 2 RD– H5579
B-6 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports Figure B-8 and Figure B-9 show the schematics of four twisted-pair cables for 1000BASE-T SFP module ports on Catalyst 3560 switches. Figure B-8 Four Twisted-Pair Straight-Through Cable Schematic for 1000BASE-T Ports Figure B-9 Four Twisted-Pair Crossover Cable Schematics for 1000BASE-T Ports Identifying a Crossover Cable To identify a crossover cable, compare the two modular ends of the cable. Hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be a different color from the wire connected to the pin on the inside of the right plug. (See Figure B-10.) 1 TP0+ 2 TP0- 3 TP1+ 6 TP1-1 TP0+ 2 TP0- 3 TP1+ 6 TP1- SwitchRouter or PC 4 TP2+ 5 TP2- 7 TP3+ 8 TP3-4 TP2+ 5 TP2- 7 TP3+ 8 TP3- 65271
B-7 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Figure B-10 Identifying a Crossover Cable Adapter Pinouts Ta b l e B - 2 lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable, and the console device. Ta b l e B - 3 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console device. NoteYou can order an RJ-45-to-DB-25 female DTE adapter, which is not supplied with the switch (ACS-DSBUASYN=). Pin 1 200915 Pin 1 Pin 1 on one connector and pin 1 on the other connector should be different colors. Table B-2 Console Port Signaling Using a DB-9 Adapter Switch Console Port (DTE)RJ-45-to-DB-9 Terminal AdapterConsole Device Signal DB-9 Pin Signal RT S 8 C T S DTR 6 DSR TxD 2 RxD GND 5 GND GND 5 GND RxD 3 TxD DSR 4 DTR CTS 7 RTS
B-8 Catalyst 3560 Switch Hardware Installation Guide OL-6337-07 Appendix B Connector and Cable Specifications Cable and Adapter Specifications Table B-3 Console Port Signaling Using a DB-25 Adapter Switch Console Port (DTE)RJ-45-to-DB-25 Terminal AdapterConsole Device Signal DB-25 Pin Signal RT S 5 C T S DTR 6 DSR TxD 3 RxD GND 7 GND GND 7 GND RxD 2 TxD DSR 20 DTR CTS 4 RTS