    A-7
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix A      Technical Specifications
    Power Requirements
    DC input voltage –36 to –72 VDC 
    3 to 1.5 A
    Power consumption 94 W, 321 BTUs per hour
    Physical Dimensions
    Weight 9 lb (4.1 kg)
    Dimensions (H x W x D) 1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm)
    Table A-13 Specifications for the Catalyst 3560V2-24TS-SD Switch (continued)
    Environmental Ranges 
    						
    							 
    A-8
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix A      Technical Specifications 
    						
    							 
    B-1
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    APPENDIXB
    Connector and Cable Specifications
    This appendix describes the Catalyst 3560 switch ports and the cables and adapters that you use to 
    connect the switch to other devices and includes these sections:
    “Connector Specifications” section on page B-1
    “Cable and Adapter Specifications” section on page B-4
    Connector Specifications
    10/100 and 10/100/1000 Ports, page B-1
    SFP Module Ports, page B-2
    Dual-Purpose Ports, page B-3
    Console Port, page B-3
    10/100 and 10/100/1000 Ports
    The 10/100 and 10/100/1000 Ethernet ports use standard RJ-45 connectors and Ethernet pinouts with 
    internal crossovers. These ports have the send (TD) and receive (RD) signals internally crossed so that 
    a twisted-pair straight-through cable and adapter can be attached to the port. Figure B-1 shows the pinout 
    for a 10/100 port. 
    						
    							 
    B-2
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Connector Specifications
    Figure B-1 10/100 Port Pinouts
    Figure B-2 shows the pinout for a 10/100/1000 port.
    Figure B-2 10/100/1000 Port Pinouts
    SFP Module Ports
    The Catalyst 3560 switch uses SFP modules for fiber-optic and copper uplinks. See the Catalyst 3560 
    release notes for a list of supported SFP modules.
    Figure B-3 Fiber-Optic SFP Module LC Connector
    H5318
    23 1 45678Pin Label
    1
    2
    3
    4
    5
    6
    7
    8RD+
    RD-
    TD+
    NC
    NC
    TD-
    NC
    NC
    60915
    23 1 45678Pin Label
    1
    2
    3
    4
    5
    6
    7
    8TP0+
    TP0-
    TP1+
    TP2+
    TP2-
    TP1-
    TP3+
    TP3-
    58476 
    						
    							 
    B-3
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Connector Specifications
    Figure B-4 Copper SFP Module RJ-45 Connector
    Dual-Purpose Ports
    The Ethernet port on a dual-purpose port uses standard RJ-45 connectors. Figure B-5 shows the pinouts.
    Figure B-5 10/100/1000 Port Pinouts
    The SFP module slot on a dual-purpose port uses SFP modules for fiber-optic and copper uplink ports. 
    See the Catalyst 3560 release notes for a list of supported SFP modules. 
    NoteThe auto-MDIX feature is enabled by default. For configuration information for this feature, see the 
    switch software configuration guide or the switch command reference. 
    Console Port
    The console port uses an 8-pin RJ-45 connector, described in Ta b l e  B - 2 and Ta b l e  B - 3. The 
    RJ-45-to-DB-9 adapter cable connects the console port of the switch to a console PC. You need an 
    RJ-45-to-DB-25 female DTE adapter (ACS-DSBUASYN=) to connect the switch console port to a 
    terminal. For console port and adapter pinout information, see Ta b l e  B - 2 and Ta b l e  B - 3.
    60915
    23 1 45678Pin Label
    1
    2
    3
    4
    5
    6
    7
    8TP0+
    TP0-
    TP1+
    TP2+
    TP2-
    TP1-
    TP3+
    TP3-
    60915
    23 1 45678Pin Label
    1
    2
    3
    4
    5
    6
    7
    8TP0+
    TP0-
    TP1+
    TP2+
    TP2-
    TP1-
    TP3+
    TP3- 
    						
    							 
    B-4
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Cable and Adapter Specifications
    Cable and Adapter Specifications
    SFP Module Cable Specifications, page B-4
    Two Twisted-Pair Cable Pinouts, page B-5
    Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports, page B-6
    Identifying a Crossover Cable, page B-6
    Adapter Pinouts, page B-7
    SFP Module Cable Specifications
    Ta b l e  B - 1 lists the cable specifications for the fiber-optic SFP module connections. Each port must 
    match the wave-length specifications on the other end of the cable, and for reliable communications, the 
    cable must not exceed the required cable length. Copper 1000BASE-T SFP transceivers use standard 
    four twisted-pair, Category 5 or greater cable at lengths up to 328 feet (100 meters). 
    Table B-1 Fiber-Optic SFP Module Port Cabling Specifications 
    SFP ModuleWavelength 
    (nanometers) Fiber TypeCore Size/Cladding 
    Size (micron)Modal Bandwidth 
    (MHz/km)1Cable Distance
    100BASE-BX 
    (GLC-FE-100BX-D 
    GLC-FE-100BX-U)1310 TX 
    1550 RXSMF G.652
    2— 32,810 feet (10 km) 
    100BASE-FX 
    (GLC-GE-100FX)1310 MMF 50/125 
    62.5/125500 
    5006,562 feet (2 km)  
    6,562 feet (2 km)
    100BASE-FX 
    (GLC-FE-100FX)1310 MMF 50/125 
    62.5/125500 
    5006,562 feet (2 km)  
    6,562 feet (2 km)
    100BASE-LX 
    (GLC-FE-100LX)1310 SMF G.652
    2— 32,810 feet (10 km) 
    1000BASE-BX10-D 
    (GLC-BX-D)1490 TX 
    1310 RXSMF G.652
    2— 32,810 feet (10 km)
    1000BASE-BX10-U 
    (GLC-BX-U)1310 TX 
    1490 RXSMF G.652
    2— 32,810 feet (10 km)
    1000BASE-SX 
    (GLC-SX-MM)850 MMF 62.5/125 
    62.5/125 
    50/125 
    50/125160 
    200 
    400 
    500722 feet (220 m) 
    902 feet (275 m) 
    1640 feet (500 m) 
    1804 feet (550 m)
    1000BASE-LX/LH 
    (GLC-LH-SM)1310 MMF
    3 
     
     
    SMF62.5/125 
    50/125 
    50/125 
    G.652
    2
    500 
    400 
    500 
    —1804 feet (550 m) 
    1804 feet (550 m) 
    1804 feet (550 m) 
    32,810 feet (10 km)
    1000BASE-ZX 
    (GLC-ZX-SM1550 SMF G.652
    2— 43.4 to 62 miles  
    (70 to 100 km)4 
    						
    							 
    B-5
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Cable and Adapter Specifications
    Two Twisted-Pair Cable Pinouts
    Figure B-6 and Figure B-7 show the schematics of two twisted-pair cables for connecting to 10BASE-T- 
    and 100BASE-TX-compatible devices.
    Figure B-6 Two Twisted-Pair Straight-Through Cable Schematic
    Figure B-7 Two Twisted-Pair Crossover Cable Schematic
    CWDM 1470, 1490, 
    1510, 1530, 
    1550, 1570, 
    1590, 1610 SMF G.6522— 62 miles (100 km)
    DWDM ITU channels 
    21-59 —— — —
    1. Modal bandwidth applies only to multimode fiber.
    2. A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers
    3. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance 
    can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, 
    you must also install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the 
    link. The mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).
    4. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends 
    on the fiber quality, the number of splices, and the connectors.
    Table B-1 Fiber-Optic SFP Module Port Cabling Specifications (continued)
    SFP ModuleWavelength 
    (nanometers) Fiber TypeCore Size/Cladding 
    Size (micron)Modal Bandwidth 
    (MHz/km)1Cable Distance
    Switch
    3 TD+
    6 TD– 
    1 RD+
    2 RD– Router or PC
    3 RD+
    6 RD–
    1 TD+
    2 TD–
    H5578
    Switch
    3 TD+
    6 TD– 
    1 RD+
    2 RD– Switch
    3 TD+
    6 TD–
    1 RD+
    2 RD–
    H5579 
    						
    							 
    B-6
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Cable and Adapter Specifications
    Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
    Figure B-8 and Figure B-9 show the schematics of four twisted-pair cables for 1000BASE-T SFP 
    module ports on Catalyst 3560 switches.
    Figure B-8 Four Twisted-Pair Straight-Through Cable Schematic for 1000BASE-T Ports
    Figure B-9 Four Twisted-Pair Crossover Cable Schematics for 1000BASE-T Ports
    Identifying a Crossover Cable
    To identify a crossover cable, compare the two modular ends of the cable. Hold the cable ends 
    side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should 
    be a different color from the wire connected to the pin on the inside of the right plug. (See Figure B-10.)
    1 TP0+
    2 TP0-
    3 TP1+
    6 TP1-1 TP0+
    2 TP0-
    3 TP1+
    6 TP1- SwitchRouter or PC
    4 TP2+
    5 TP2-
    7 TP3+
    8 TP3-4 TP2+
    5 TP2-
    7 TP3+
    8 TP3-
    65271 
    						
    							 
    B-7
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Cable and Adapter Specifications
    Figure B-10 Identifying a Crossover Cable
    Adapter Pinouts
    Ta b l e  B - 2 lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable, and the console device.
    Ta b l e  B - 3 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console 
    device. 
    NoteYou can order an RJ-45-to-DB-25 female DTE adapter, which is not supplied with the switch 
    (ACS-DSBUASYN=).
    Pin 1
    200915
    Pin 1 Pin 1 on one connector and 
    pin 1 on the other connector
    should be different colors.
    Table B-2 Console Port Signaling Using a DB-9 Adapter 
    Switch 
    Console 
    Port (DTE)RJ-45-to-DB-9 
    Terminal AdapterConsole 
    Device
    Signal DB-9 Pin Signal
    RT S 8 C T S
    DTR 6 DSR
    TxD 2 RxD
    GND 5 GND
    GND 5 GND
    RxD 3 TxD
    DSR 4 DTR
    CTS 7 RTS 
    						
    							 
    B-8
    Catalyst 3560 Switch Hardware Installation Guide
    OL-6337-07
    Appendix B      Connector and Cable Specifications
    Cable and Adapter Specifications
    Table B-3 Console Port Signaling Using a DB-25 Adapter  
    Switch 
    Console 
    Port (DTE)RJ-45-to-DB-25 
    Terminal AdapterConsole 
    Device
    Signal DB-25 Pin Signal
    RT S 5 C T S
    DTR 6 DSR
    TxD 3 RxD
    GND 7 GND
    GND 7 GND
    RxD 2 TxD
    DSR 20 DTR
    CTS 4 RTS 
    						
    All Cisco manuals Comments (0)