J Series Serial Commands Technical Reference Information61 of 90020-100796-01 Rev. 1 (10-2011) (NET) Network Setup con’t HOST Set the host name. MAC0 Gets the MAC address of the first ethernet controller. PORT Set the PORT number. SUB0 Set the network subnet mask for the first ethernet controller. EXAMPLES: (NET+ETH0 192.168.1.35) - Set new IP address on the first ethernet controller. (NET+GATE 192.168.0.1) - Set the gateway. (NET+SUB0 255.255.255.0) - Set the subnet mask on the first ethernet controller. (NET+HOST MyHostName) - Set the host name. (NET+DOMA MyDomainName) - Set the domain name. (NET+ETH0 ?) - Retrieve IP address from first controller. (NET+ETH0! 192.168.1.35). (NET+ETH0 ?) - Retrieve IP address from second controller. (NET+ETH1! 192.168.1.36). (NET+MAC0 ?) - Retrieve MAC address from first controller. (NET+MAC0! 00:12:3F:7B:76:B4). (NET+GATE ?) - Retrieve default gateway. (NET+GATE! 192.168.0.1). (NET+PORT 3002) - Set the Port number. (NET+PORT ?) - Retrieve the Port number. (NET+PORT! 3002). (NRB) BLOCK ARTIFACT REDUCTION CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Block Artifact Reduction (BAR) locates and reduces block edges produced by discrete cosine transform (DCT) based compression processing. SUBCODE INxy DESCRIPTION OF USE Set the BAR for slot x, input y. MAIN Set the BAR for main video. PIIP or SECD Set the BAR for PIP or Secondary video. EXAMPLE: (NRB 32) - Set the BAR to mid point for main video. (NRD) GENERAL NOISE REDUCTION CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adaptive general noise reduction selects a filter sensitivity to noise. A higher value may improve noisy sources, although it will soften the image. SUBCODE INxy DESCRIPTION OF USE Set the noise reduction for slot x, input y. MAIN Set the noise reduction for main video. PIIP or SECD Set the noise reduction for PIP or Secondary video.
62 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (NRD) General Noise Reduction con’t EXAMPLE: (NRD 32) - Set the noise reduction to mid point for main video. (NTR) NETWORK ROUTING CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set routing for ASCII messages. SUBCODE DESCRIPTION OF USE Used to enable or disable daisy chaining. 0 = RS232, RS422 & Ethernet communications are all separate from one another 1 = RS422 port(s) is/are connected to the RS232 network 2 = The Ethernet port is connected to the RS232 network 3 = RS232, RS422 & Ethernet are all connected to each other EXAMPLES: (NTR?l) - List routing options. (NTR 0) - Each connection is routed separately. (NTR 3) - Full daisy-chaining. (OPP) ODD PIXEL PHASE CONTROL GROUP: Option SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adds an offset to the pixel phase setting on this card. It is used to compensate for differences between the A to D converter used to sample even pixels, and the one used for odd pixels. A value of 0 is the null position in which both A and D converters are set to exactly the same value. SUBCODE SLx0 DESCRIPTION OF USE Set a pixel phase offset for the second A to D. EXAMPLE: (OPP+SL10 -1) - Set a pixel phase offset to -1 on slot 1. (OSD) ON SCREEN DISPLAY CONTROL GROUP: Unsaved SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Display or Hide the OSD screen. SUBCODE DESCRIPTION OF USE Turn on/off OSD display. EXAMPLES: (OSD ?) - Get current state of OSD. 0 when OSD is hidden, 1 when OSD is displayed. (OSD 0) - Turn off OSD display. The OSD will run in the background, even though it is not visible.
J Series Serial Commands Technical Reference Information63 of 90020-100796-01 Rev. 1 (10-2011) (OST) OSD TRANSPARENCY CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enable or Disable on screen display transparency. SUBCODE DESCRIPTION OF USE Enable or disable OSD transparency. EXAMPLE: (OST 1) - Enable OSD transparency. (PBC) PIP BORDER COLOR CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control lets you choose the color of the optional border around the picture-in-picture image. The border can be disabled by setting the border width PBW to zero. Valid options are: 0 = Black 1 = Dark Red 2 = Dark Green 3 = Dark Yellow 4 = Dark Blue 5 = Dark Magenta 6 = Dark Cyan 7 = Dark Grey 8 = Light Grey 9 = Red 10 = Green 11 = Yellow 12 = Blue 13 = Magenta 14 = Cyan 15 = White SUBCODE DESCRIPTION OF USE Select border color for PIP window. EXAMPLE: (PBC 0) - Select black PIP border. (PBW) PIP BORDER WIDTH CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Selects whether a border should be placed around the PIP window. Setting the width to zero (0) will remove the border. Setting it to 1 will enable the border. SUBCODE DESCRIPTION OF USE Select border width for PIP window. EXAMPLE: (PBW 10) - Select PIP border width of 10.
64 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PDT) PEAK DETECTOR CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Enables or disables the peak detector test mode. This is used to aid in setup of input levels. For each color, pixel values very near black will be displayed black, pixel values very near peak level will be displayed full on. All oth- ers will be displayed in mid level grey. Input levels for each color should be adjusted so that black pixels in the image just turn black, and full on pixels just turn full on. When adjustment is completed this control should be disabled to allow display of all grey levels. This control takes place before the scaler/deinterlacer. SUBCODE DESCRIPTION OF USE Enable or disable peak detector. EXAMPLES: (PDT 1) - Turn on peak detector. (PDT 0) - Turn off peak detector. (PHP) PIP HORIZONTAL POSITION CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Sets the horizontal position of the PIP window. Specifies where to place the center of the PIP window horizon- tally on the panel in pixels. SUBCODE DESCRIPTION OF USE Set PIP horizontal position. EXAMPLES: (PHP 100) - Set PIP horizontal position to 100 pixels. (PHP?)(PHP!100) - Get PIP horizontal position. (PHS) PIP HORIZONTAL SIZE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Sets the size (width) of the PIP window in pixels. The active portion of the input signal, as determined by blank- ing controls, will be scaled to fit into the PIP window. The height of the PIP window will be set to maintain the aspect ratio of the image being captured, as determined by the vertical stretch control. SUBCODE DESCRIPTION OF USE Set PIP horizontal size. EXAMPLES: (PHS 100) - Set PIP size to 100 pixels. (PHS?)(PHS!100) - Get PIP size.
J Series Serial Commands Technical Reference Information65 of 90020-100796-01 Rev. 1 (10-2011) (PIP) PICTURE IN PICTURE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control enables or disables Picture in Picture (PIP) mode. When this control is enabled for the first time, the first valid video signal starting at slot 1 input 1 is routed to the PIP window. If no signals are present, the first available slot/input combination is selected. PIP and image transition effects (seamless switching) both require resources to configure a second image process- ing path. Therefore these two features cannot be active at the same time. SUBCODE DESCRIPTION OF USE Enable or disable PIP window. EXAMPLES: (PIP 0) - Disables PIP video. (PIP 1) - Enables PIP video. (PIP 2) - Enables PBP video (picture-by-picture) (PIP ?) - Returns the state of the PIP control. i.e. (PIP! 1) - PIP enabled. (PJH) PROJECTOR HOURS CONTROL GROUP: Unsaved SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Reports the number of hours elapsed on the projector. This control is read-only. SUBCODE DESCRIPTION OF USE Read projector hours. EXAMPLE: (PJH ?) - Returns hours elapsed on projector. (PLK) USER LOCKOUTS CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Admin DESCRIPTION User lockouts provide a way to lock various controls in the system, protecting them against accidental or unwanted user adjustment. SUBCODE DESCRIPTION OF USE Set/get a sequence of codes/subcodes that are locked out from user adjustment. ENBL Set the master enabled switch - when unselected, user locks are ignored.
66 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PLK) PIP User Lockouts con’t EXAMPLES: (PLK L*) - Locks all codes/subcodes in the system (except the PLK and PWR control, which are unlockable) (PLK U*) - Unlocks all codes/subcodes in the system, regardless of which method was used to lock them (PLK LSIN*) - Locks all subcodes within the SIN control (PLK USIN+PIIP) - Following the previous example, this unlocks SIN+PIIP, leaving all other SIN subcodes locked (PLK LSIN* LGAM) - Locks all SIN subcodes, and locks the GAM code (PLK?)(PLK!LSIN* LGAM) - Returns the list of user lockouts (PMT) PICTURE MUTE CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Mutes the displayed image (image goes black) without closing the mechanical shutter. When the image is muted, all DMD mirrors will be turned to the off position. SUBCODE DESCRIPTION OF USE Mute/Unmute the image. EXAMPLES: (PMT 1) - Mutes the picture. (PMT 0) - Unmutes the picture. (PNG) PING CONTROL GROUP: Configuration SUBCLASS: Power Down ACCESS LEVEL: Status DESCRIPTION This command returns basic projector information to the user which includes the type of device & main software version. Note that some devices have multiple CPUs each with its own software version. Only the software version of what is considered to be the master CPU, is returned here. The return parameters are: Type, Major, Minor, Beta. The beta value is optional meaning it is an engineering build and has not been validated. Note: List of devices: 40 = ACT, 41 = Cinema, 42 = CinemaMini, 43 = Media Block, 44 = M Series, 46 = J Series SUBCODE DESCRIPTION OF USE Read projector information. EXAMPLE: (PNG?)(PNG!41 001 000 234) - Indicates Cinema type, software: 1 major, 0 minor, 234 beta.
J Series Serial Commands Technical Reference Information67 of 90020-100796-01 Rev. 1 (10-2011) (PPA) POSITION PRESET ASPECT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION When enabled, this control ensures that during auto setup for any source, its aspect ratio is maintained when its default size is calculated. This is similar to cases where a stretch is defined for a source in the lookup table. If dis- abled and no stretch is defined, the source is scaled to fit the screen. SUBCODE DESCRIPTION OF USE Maintain or do not maintain aspect during auto setup. EXAMPLES: (PPA 0) - Disables maintain aspect during auto setup. (PPA 1) - Enables maintain aspect during auto setup. (PPP) PIP POSITION PRESET CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Choose a preset location and size for the PIP window. The Location settings will adjust the size and position of the window. Blanking will not be affected. While in split screen mode, several channel controls that resize image will be disabled. These controls are size, H-Position and V-Position. Valid values are: 0 = Top Right 1 = Top Left 2 = Bottom Left 3 = Bottom Right SUBCODE DESCRIPTION OF USE Select PIP window location. EXAMPLE: (PPP 0) - Select top left preset position. (PPS) PIP SWAP CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control swaps the current main and PIP inputs. It will swap the inputs regardless if there are valid signals on either of the inputs. SUBCODE DESCRIPTION OF USE Swap Main and PIP input. EXAMPLE: (PPS) - Swap inputs.
68 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PRT) SERIAL PORT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Status DESCRIPTION Get a list of serial ports available on the device. SUBCODE DESCRIPTION OF USE Read serial ports. EXAMPLE: (PRT?1) - Get list of ports. (PTL) SERIAL PROTOCOL CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the protocol for a serial communications port. SUBCODE PRTA DESCRIPTION OF USE Set the protocol on port A (RS232 In) pass through PRTB Set the protocol on port B (RS232 Out). PRTC Set the protocol on port C (RS422). EXAMPLES: (PTL+PRTA RAW) - Set protocol on port A to a pass through raw data protocol. (PTL+PRTA CHRISTIE) - Set protocol on port A to a Christie Digital serial protocol. (PTL+PRTA?) - Get protocol (PTL+PRTA!RAW). (PVP) PIP VERTICAL POSITION CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Sets the vertical position of the PIP window. Specifies where to place the center of the PIP window vertically on the panel in pixels. SUBCODE DESCRIPTION OF USE Set vertical position of PIP window. EXAMPLES: (PVP 100) - Set PIP vertical position to 100 pixels. (PVP?)(PVP!100) - Get PIP vertical position.
J Series Serial Commands Technical Reference Information69 of 90020-100796-01 Rev. 1 (10-2011) (PWR) POWER CONTROL GROUP: Unsaved SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Change the power state of the projector. Possible values: 0 = Power-Off (to Standby mode) 1 = Power-On (to Lamps On mode) 10 = Cooldown lamp is cooling down. Controlled by lamp (read-only) 11 = Warmup lamp is warming up. Controlled by lamp (read-only) 20 = AutoShutdown mode 1 (read only) 21 = AutoShutdown mode 2 (read only) 22 = AutoShutdown mode 3 (read only) 23 = Emergency Shutdown, ending in Power Off SUBCODE RBFS DESCRIPTION OF USE Reboots the projector into failsafe mode. The projector must be in Standby mode before initiating this command EXAMPLES: (PWR?) - Get projector power status. (PWR1) - Turn the lamp and all electrical power on. (PWR0) - Set the projector to standby mode. (PWR+RBFS 1) - Reboot into failsafe mode. (PXP) PIXEL PHASE CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Pixel Phase adjusts the phase of the pixel sampling clock relative to the incoming signal. This allows you to fine tune the sampling point within one pixel. Adjust the Pixel Phase when the image (usually from an RGB source) shows shimmer. Note that if the shimmer is concentrated in vertical bands with little or no shimmer between the bands, then it is likely that Pixel Tracking needs adjustment. Pixel Tracking must be set correctly before adjusting Pixel Phase. Pixel Phase can only be set on Analog input cards. The range is 0-31. SUBCODE INxy DESCRIPTION OF USE Set the pixel phase for slot x, input y. MAIN Set the pixel phase for the main image. PIIP or SECD Set the pixel phase for the PIP or Secondary image. EXAMPLES: (PXP 16) - Set pixel phase to 16 on main video. (PXP+MAIN 16) - Set pixel phase to 16 on main video. (PXP+PIIP 16) - Set pixel phase to 16 on PIP video. (PXP+IN32 16) - Set pixel phase to 16 on slot 3 input 2. (PXP?) - Returns the pixel phase value on main video. (PXP+PIIP?) - Returns the pixel phase value on PIP video. (PXP+IN12?) - Returns the pixel phase value on slot 1 input 2.
70 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (PXT) PIXEL TRACKING CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Pixel Tracking adjusts the position of the pixel sampling clock to match the input signal. It can only be set on Analog input cards. If adjusted incorrectly, flickering or vertical bars of noise appear across the image. Adjust Pixel Tracking so that the noise either disappears or fills the image. If it fills the image, use Pixel Phase to elimi- nate the noise. The range is 600-3000. SUBCODE INxy DESCRIPTION OF USE Set the pixel tracking for slot x, input y. MAIN Set the pixel tracking for the main image. PIIP or SECD Set the pixel tracking for the PIP or Secondary image. EXAMPLES: (PXT 600) - Set pixel tracking to 600 on main video. (PXT+MAIN 600) - Set pixel tracking to 600 on main video. (PXT+PIIP 600) - Set pixel tracking to 600 on PIP video. (PXT+IN32 600) - Set pixel tracking to 600 on slot 3 input 2. (PXT?) - Returns the pixel tracking value on main video. (PXT+PIIP?) - Returns the pixel tracking value on PIP video. (PXT+IN12?) - Returns the pixel tracking value on slot 1 input 2. (RAL) REMOTE ACCESS LEVEL CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Admin DESCRIPTION Set the remote serial protocol access level for a serial communications port. Note: Valid selections are 0 - No Access, 1 - Login Required, 2 - Free Access Default value is 1 - Login required. SUBCODE DESCRIPTION OF USE Set the access level on Ethernet all ports. PRTA Set the access level on port A (RS232 In). PRTB Set the access level on port B (RS232 Out). PRTC Set the access level on port C (RS422). EXAMPLES: (RAL 0) - Disable remote serial protocol access level for all Ethernet ports. (RAL?) - Get access level for Ethernet ports (RAL!0). (RAL+PRTA 2) - Set remote serial protocol access level on port A (RS232 In) to free access. (RAL+PRTA?) - Get access level (RAL+PRTA!2).