J Series Serial Commands Technical Reference Information51 of 90020-100796-01 Rev. 1 (10-2011) (LCB) Lens System Calibration con’t MNZF Enable manual zoom/focus control. When set the zoom and focus motors are de-energized and will not be under the control of ILS. Zoom and focus will be adjustable by hand. If not set, all lens motors will be under ILS control and users should not attempt to adjust manually, as this will damage the motors. LOCK Lock all lens motors, preventing the lens from moving. This overrides all other lens functions. EXAMPLES: (LCB) - Calibrate all motors (LCB+STAT?) - Get the current status for lens motor calibration. (LCB+HOME) - Reset H & V motors to their optical home position. (LCB+APWR 1) - Enable Auto Lens Reset on Power-Up. (LCB+ANEW 0) - Disable Auto Lens Calibration on lens insertion. (LCB+ANEW?) - Get state of Auto Lens Calibration. (LCB+LOCK1) - Lock all lens motors in their current positions. (LCB+MNZF 1) - Set manual zoom/focus mode. You can adjust the motors by hand now. (LCB+MNZF 0) - Re-energize zoom/focus motors. The motors will automatically re-locate the center flag and stay at their center position. (LCD) LCD BACKLIGHT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Controls the backlight options for the LCD Keypad. Backlight time-out length, backlight intensity (brightness) and forcing backlight to stay off. SUBCODE KEEP DESCRIPTION OF USE 0 - backlight always on, 1 - backlight always off, 2 - timer (see examples). LEVL (0-25) - Backlight Intensity Level (brightness). 0 for off, 25 for max. TIME (5 - 600) - Time in seconds the backlight will remain on after a key is pressed. EXAMPLES: (LCD+TIME 5) - 5 seconds after a key is pressed on the keypad, the backlight will go off. (LCD+TIME 600) - 10 minutes after a key is pressed on the keypad, the backlight will go off. (LCD+KEEP 0) - Backlight will always stay on. (LCD+KEEP 1) - Backlight will always stay off. (LCD+KEEP 2) - Backlight will stay on for the number of seconds set in LCD+TIME. The backlight will always stay on if an alarm is raised or if you are on the lcd test screen. (LCD+LEVL 25) - Maximum lcd backlight brightness. (LCD+LEVL 10) - Low lcd backlight brightness.
52 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (LDT) LEVEL DETECTOR CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This Level Detector control changes the gamma table settings to make it easy for the user to adjust the input lev- els. It causes the data to be processed so that all levels below a specified value are set to black (0) and all above and including it are set to white (1024). This control takes place before the scaler/deinterlacer. SUBCODE DESCRIPTION OF USE Enable or disable level detector. EXAMPLES: (LDT 1) - Turn on level detector. (LDT 0) - Turn off level detector. (LDV) LEVEL DETECTOR VALUE CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION The Level Value control specifies the value to be used by the level detector. The range is 1-1023. This control takes place before the scaler/deinterlacer. SUBCODE DESCRIPTION OF USE Set level detector valve. EXAMPLE: (LDV 500) - Set level detector to 500. All data greater than or equal to 500 will be shown in the image. (LHO) LENS HORIZONTAL POSITION ADJUSTMENT CONTROL GROUP: Configuration SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adjust the lens to a specific horizontal position. This control moves the image horizontally by moving the whole display area. This is different from the Position control which moves the image electronically within a fixed display area. SUBCODE DESCRIPTION OF USE Move the lens mount to a specified horizontal position. The default data range is -2050 to 2050. EXAMPLE: (LHO 500) - Move lens mount to position 500 on the horizontal axis.
J Series Serial Commands Technical Reference Information53 of 90020-100796-01 Rev. 1 (10-2011) (LLC) LITELOC CALIBRATION CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Service DESCRIPTION Calibrate the LiteLoc sensor. This control will be disabled until the projector is ready to be calibrated, so the fol- lowing conditions must be met first: i) The projector must have Dual lamps on. ii) The lamps must have warmed up for at least 5 minutes. The calibration will take approximately 1 1/2 minutes to complete. The shutter will be closed for the duration of the calibration, and will open again when the calibration is complete. “Constant Intensity” mode cannot be used if the LiteLoc sensor has not been calibrated. SUBCODE DESCRIPTION OF USE Calibrate the sensor. EXAMPLE: (LLC) - Initiate the calibration cycle. (LMV) ADJUST LENS POSITION/LENS MOVE CONTROL GROUP: Unsaved SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adjust all 4 lens motors simultaneously, or move any lens motor arbitrarily (i.e. move motor indefinitely, rather than to some absolute position). SUBCODE DESCRIPTION OF USE Move all lens motors with (LMV h v z f) where h, v, z, f represent the horizontal, vertical, zoom and focus position information. HSTP Move the horizontal lens motor a relative # steps. VSTP Move the vertical lens motor a relative # steps. FSTP Move the focus lens motor a relative # steps. ZSTP Move the zoom lens motor a relative # steps. HRUN Start/stop/reverse the horizontal lens motor. VRUN Start/stop/reverse the vertical lens motor. FRUN Start/stop/reverse the focus lens motor. ZRUN Start/stop/reverse the zoom lens motor. EXAMPLES: (LMV 1000 1500 500 -500) - Set the lens to H:1000, V:1500, Z:500, F:-500 (LMV+HRUN1) - Start to move horizontal motor toward positive max position (LMV+VRUN0) - Stop the vertical motor. (LMV+ZRUN-1) - Start to move horizontal motor toward negative max position (LMV+HSTP45) - Move the horizontal motor 45 steps in the positive direction (LMV+ZSTP-300) - Move the zoom motor 300 steps in the negative direction
54 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (LOC) LOCAL SETTINGS CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the localization options such as Language and display options for temperature units. SUBCODE LANG DESCRIPTION OF USE Set the system language: 0 - English 1 - French 2 - German 3 - Spanish 4 - Italian 5 - Chinese 6 - Japanese 7 - Korean TEMP Set the temperature units. 0 - Celsius 1 - Fahrenheit EXAMPLES: (LOC+TIME 1) - Set timezone to standard 12 hour. (LOC+TIME?l) - Get list of formats. (LOC+TIME?)(LOC+TIME!001) - Get time format. (LOS) LOOP OUT SOURCE SELECTION CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION This control is used to configure the HDMI output options and selects the loop out source for the transmitters of the THIC card. Selecting Direct Loop will directly pass-through the HDMI input signals: on the same Twin HDMI Input Card, the Input1 signal is looped to Output1 and the Input2 signal is looped to Output2. Selecting Main/PIP Loop will loop the Main & PIP video to the outputs, regardless from which card these signals origi- nate. The Main video signal is looped to Output1 and the PIP video signal is looped to Output2. Selecting Dis- able will shut off the HDMI outputs completely. SUBCODE DESCRIPTION OF USE Set loop out source selection EXAMPLES: (LOS 0) - Shut off loop out (LOS 1) - Set loop out source to be local on slot 1 (LOS 2) - Set loop out source to be the Main/PIP images (LOS ?) - Get loop out source selection on slot 1
J Series Serial Commands Technical Reference Information55 of 90020-100796-01 Rev. 1 (10-2011) (LPI) LAMP INTENSITY CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adjust the lamp intensity (% of full). SUBCODE DESCRIPTION OF USE Set lamp intensity. EXAMPLE: (LPI 80) - Set the intensity set point to 80. (LPL) LAMP LIFE CONTROL GROUP: Saved SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set the number of lamp hours of usage at which a warning must be given. When that number of hours is reached on either lamp, a warning message will be added to the status system indicating that the lamp should be changed. This is a user settleable limit only, and does not guarantee any number of hours for lamp life. This control has no bearing on lamp warranty and is not tied to actual lamp life in any way. The default is 0, which means that the fea- ture is off and no warning will be generated. SUBCODE DESCRIPTION OF USE Set the limit for the lamp hours warning. EXAMPLES: (LPL 2000) - A system health warning will be displayed when the lamp has run for 2000 hours. (LPL 0) - Lamp life monitoring is not used. (LPM) LAMP MODE CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Selects the lamp power control method, which determines how the lamp power and intensity are controlled. If Maximum Brightness, the lamp burns as brightly as possible. Select Intensity mode to maintain a specific brightness level over time - as the lamp ages, the projector will increase power as needed to closely maintain the required output from the lamp. Select Power to specify the power level supplied to the lamp. Both Intensity and Power modes allow you to extend lamp life. Valid values are: 0 = Maximum Brightness 1 = Constant Intensity 2 = Constant Power SUBCODE DESCRIPTION OF USE Set the lamp operation to be power, maximum, or intensity con- trolled. EXAMPLE: (LPM 2) - Control lamp(s) with constant power.
56 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (LPP) LAMP POWER CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Set the lamp power in Watts. This actually scales the power to lamp gain, the true control parameter. The Power control represents the amount of power sent to the lamps. Power increases when operating in Intensity mode, until it reaches its maximum. The value remains stable when in Max Brightness or Power mode. If using Power mode, setting a lower power level reduces brightness and extends lamp life. SUBCODE DESCRIPTION OF USE Set the Lamp power. EXAMPLE: (LPP 300) - Sets lamp power to 300W. (LVO) LENS VERTICAL OFFSET POSITION ADJUSTMENT CONTROL GROUP: Configuration SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Adjust the lens to a specific vertical position. This control moves the image horizontally by moving the whole display area. This is different from the Position control which moves the image electronically within a fixed display area. SUBCODE DESCRIPTION OF USE Move the lens mount to a specified vertical position. The default data range is -2050 to 2050. EXAMPLE: (LVO 500) - Move lens mount to position 500 on the vertical axis. (MBE) MESSAGE BOX ENABLE CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION This control enables the displaying of groups of message boxes on the OSD. SUBCODE AUTO DESCRIPTION OF USE Enable or disable the pop-up of automatic message boxes. These are messages to the user that are not directly triggered by user actions. Examples are signal information, function limitation or auto calibration message boxes. USER Enable or disable the pop-up of message boxes that are directly triggered by user actions. Examples are gamma or lens control message boxes. 3DST Enable or disable the pop-up of message boxes that are triggered by 3D setup errors.
J Series Serial Commands Technical Reference Information57 of 90020-100796-01 Rev. 1 (10-2011) (MBE) Message Box Enable con’t EXAMPLES: (MBE+AUTO ?) - Get current auto message boxes enable state. (MBE+ AUTO 0) - Set auto message boxes to not be displayed. (MBE+AUTO 1) - Set auto message boxes to be displayed. (MBE +USER ?) - Get current user message boxes enable state. (MBE+USER 0) - Set user message boxes to not be displayed. (MBE+USER 1) - Set user message boxes to be displayed. (MCS) MENU CASCADING ENABLE CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Enable or disable cascading menus. When disabled, a single menu level will be displayed at a time. NOTE: When Tiling is enabled, this function is not available, the menu is in a fixed position and is non-cascading. SUBCODE DESCRIPTION OF USE Enable or disable cascading. EXAMPLES: (MCS ?) - Get the current state of this setting. (MCS 0) - Disable cascading menus. (MCS 1) - Enable cascading menus. (MDE) SERIAL MODE CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Advanced DESCRIPTION Set the mode for a serial communications port. Settings such as bits, parity and stop bits are grouped together into one selection. SUBCODE PRTA DESCRIPTION OF USE Set the mode on port A (RS232 In). PRTB Set the mode on port B (RS232 Out). PRTC Set the mode on port C (RS422). EXAMPLES: (MDE+PRTA 8N1) - Set mode on port A to 8-bit, no parity, 1 stop bit. (MDE+PRTA 7E1) - Set mode on port A to 7-bit, even parity, 1 stop bit. (MDE+PRTA 7O1) - Set mode on port A to 7-bit, odd parity, 1 stop bit. (MDE+PRTA?) - Get mode (MDE+PRTA!8N1). (MFT) MENU FONT CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set the font size used by OSD.
58 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (MFT) Menu Font con’t SUBCODE DESCRIPTION OF USE View/Set Choose large font or small font as the font used by OSD. EXAMPLES: (MFT ?) - Get current font option used by the OSD. 0 is small font, 1 is large font. (MFT 1) - Use large font as the OSD font. (MLK) CHANNEL MEMORY LOCK CONTROL GROUP: Channel SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Lock a channel from being edited. SUBCODE C0xx DESCRIPTION OF USE Lock channel (xx=channel number from 01 to 99). MAIN Lock the channel being used by main. PIIP or SECD Lock the channel being used by PIP or Secondary. EXAMPLES: (MLK?) - get channel locked state for channel used by main. (MLK+MAIN?) - Get channel locked state for channel used by main. (MLK+PIIP?) - Get channel locked state for channel used by PIP. (MLK 1) - Lock the channel being used by main. (MLK+PIIP 1) - Lock the channel being used by PIP. (MLK+MAIN 0) - Unlock the channel being used by main. (MLK+C001 0) - Unlock channel 1. (MNR) MOSQUITO NOISE REDUCTION CONTROL GROUP: Input SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Mosquito Noise Reduction (MNR) dynamically adapts to image content, effectively reducing mosquito artifacts around sharp edges in DCT based compression. SUBCODE INxy DESCRIPTION OF USE Set the mosquito noise reduction for slot x, input y. MAIN Set the mosquito noise reduction for main video. PIIP or SECD Set the mosquito noise reduction for PIP or Secondary video. EXAMPLE: (NRB 32) - Set the mosquito noise reduction to mid point for main video.
J Series Serial Commands Technical Reference Information59 of 90020-100796-01 Rev. 1 (10-2011) (MNU) MENU SETTINGS AND CONFIGURATION CONTROL GROUP: Preference SUBCLASS: Power Down ACCESS LEVEL: Operator DESCRIPTION Set menu type, view OSD state, read menu structure. SUBCODE DESCRIPTION OF USE View/change the current state of the OSD (0=presentation, 1=main, 2=submenu). EXAMPLE: (MNU?)(MNU!0) (MSH) MENU SHIFT HORIZONTAL CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Change the horizontal position of the main menu. If the position is not from one of the preset positions, MSP will be changed to custom. SUBCODE DESCRIPTION OF USE View/set the horizontal position of the main menu. EXAMPLES: (MSH ?) - Get current horizontal position of main menu. (MSH 50) - Set main menu horizontal position to 50 pixels from left edge. (MSP) MENU LOCATION CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Set the default menu position on the screen. Valid options are: 0 = 4:3 TopLeft 1 = 4:3 Inset 1 2 = 4:3 Inset 2 3 = 16:9 TopLeft 4 = 16:9 Inset 1 5 = 16:9 Inset 2 NOTE: When Tiling is enabled, this function is not available, the menu is in a fixed position (top-left) and is non- cascading. SUBCODE DESCRIPTION OF USE View/set the preset menu position. EXAMPLES: (MSP ?) Get current menu position preset. (MSP 0) Set main menu position to 4:3 TopLeft, the top left corner of screen.
60 of 90J Series Serial Commands Technical Reference Information020-100796-01 Rev. 1 (10-2011) (MSV) MENU SHIFT VERTICAL CONTROL GROUP: Preference SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Change the vertical position of the main menu. If the position is not from one of the preset positions, MSP will be changed to custom. SUBCODE DESCRIPTION OF USE View/set the vertical position of main menu. EXAMPLES: (MSV ?) - Get current vertical position of main menu. (MSV 50) - Set main menu vertical position to 50 pixels from top edge. (NAM) CHANNEL NAME CONTROL GROUP: Channel SUBCLASS: Power Up ACCESS LEVEL: Operator DESCRIPTION Channel Name is optional text assigned to a channel and can appear in the Channel Setup menu, Channel Edit menu, the channel list and the Status menu. SUBCODE C0xx DESCRIPTION OF USE Set the channel name for the channel (xx=channel number from 01 to 99). MAIN Set the channel name for the channel being used by main. PIIP or SECD Set the channel name for the channel being used by PIP or Second- ary. EXAMPLES: (NAM?) - Get current active channel name for main video. (NAM+MAIN?) - Get channel name being used by main. (NAM+PIIP?) - Get channel name being used by PIP. (NAM Test) - Set channel name being used by main to Test. (NAM+PIIP Test) - Set channel name being used by PIP to Test. (NAM+MAIN Test) - Set channel name being used by main to Test. (NAM+C001 Test) - Set channel name for channel 1 to Test. (NET) NETWORK SETUP CONTROL GROUP: Config/Preference SUBCLASS: Power Down ACCESS LEVEL: Admin DESCRIPTION Set or request the network setup for this device. SUBCODE DOMA DESCRIPTION OF USE Set the domain name ETH0 Set the IP address for the first ethernet controller. GATE Set the network gateway.