41 4.Place the document whose image you want to project onto the document camera’s document stage. Be sure to place the document in the center of the stage, and do not let any part of the document extend off the edges of the stage. When placing a landscap e orientation document onto the document stage, the top of the page should face towards the camera stand. Initially the monitor image will be projected, and so the image will appear a bit fuzzy. When the document camera senses that the document on the stage is not being moved, it will record its image and switch from the fuzzy monitor image to a high-resolution image (recorded image) automatically. 5.Now you can replace the document currently on the stage with another one. This will switch to the recorded im age of the next document automatically. NoteStep 5 above is what happens wh ile the Data Projector’s YC Camera application is configured with its initial default settings. The recorded image will not switch automatically if you have changed the “Operation Mode” se tting of the YC Camera application to “Manual Capture”. For more information, see “YC Camera Applic ation Setup Menu Contents” on page 48. Rough (Monitor) Image Recorded Image
42 This section explains the various types of projection operations you can perform with the YC Camera application and how to configure YC Camera application settings. Important!The procedures in this section assume that you have already connected the Document Camera to the Data Projector as explained under “Connecting the Document Camera to the Data Projector” (page 39), and that the Data Proj ector’s YC Camera application is running. YC Camera Application Projection Operations The operations in this section are performed using the YC Camera function menu, which appears when you press the [FUNC] key while the YC Camera application is running. Some operations can be performed using the remote controller’s [O], [ f ], and [ Z] keys. To release the document camera shutter manually 1.Press the [FUNC] key to display the YC Camera application function menu. The “Camera Shutter” item should be highlighted by default. 2.Press the [ENTER] key to release the document camera shutter. This will cause the image recorded with the document camera to be projected. NoteWhile a rough monitor image or recorded image is projected, you can release the shutter manually by pressing the [ENTER] key, without pressing the [FUNC] key. YC Camera Application Operations
43 To adjust the document camera’s zoom setting 1.Press the [FUNC] key to display the YC Camera application function menu. 2.Use the [] key to move the highlighting to “Camera Zoom/Focus” and then press the [ENTER] key. This causes the YC Camera Zoom/Focus dialog box to appear in the projection area. The “Optical Zoom” item should be highlighted by default. 3.Use the [ ] and [ ] keys to adjust the docume nt camera’s zoom setting. 4.After the zoom setting is the way you want, press the [ESC] key. This will close the YC Camera Zoom/Focus dialog box. To adjust document focus manually 1.Press the [FUNC] key to display the YC Camera application function menu. 2.Use the [] key to move the highlighting to “Camera Zoom/Focus” and then press the [ENTER] key. This causes the YC Camera Zoom/Focus dialog box to appear in the projection area. 3.Press the [ ] key to move the highlighting to “Focus”. 4.Use the [ ] and [ ] keys to adjust the document camera’s focus. 5.After the focus is the way you want, press the [ESC] key. This will close the YC Camera Zoom/Focus dialog box.
44 To adjust the camera position 1.Remove all documents and objects from the document stage. 2.Press the [FUNC] key to display the YC Camera application function menu. 3.Use the [] key to move the highlighting to “Adjust Camera Position” and then press the [ENTER] key. This displays the camera position adjustment dialog box. 4.Point the document camera downwards so the lens is pointed towards the document stage. Aim the camera as instructed by the text that appears in the projection area. When the document camera is positioned corr ectly, position adjustment will end and the dialog box will close. At this time the monitor screen (the image being picked up by the document camera) wi ll be projected. To rotate the currently projected image 1.Press the [FUNC] key to display the YC Camera application function menu. 2.Use the [] key to move the highlighting to “Rotate Right” and then press the [ENTER] key. This will rotate the projected image 90 degrees to the right. Instead of steps 1 and 2 above, you can also rotate the projected image by pressing the [ O] key. NoteThis operation will affect only the image that is currently being projected. The projection image produced the next time you releas e the shutter will be projected in accorda nce with the settings on the YC Camera Application Setup Menu (page 46).
45 To perform white enhancement on the currently projected image NoteWhite enhancement causes the background of the projected image to be white enhanced, which helps to make the text on a document easier to read. This operation will affect only the image that is currently being projected. The projection image produced the next time you release the shutter will be projected in accordance with the settings on the YC Camera A pplication Setup Menu (page 46). Important!You can perform white enhancement only on a projected image that has been skew corrected. For more information, see the note under “To perform manual skew correction on the currently projected image” (page 45). 1.Press the [FUNC] key to display the YC Camera application function menu. 2.Use the [] key to move the highlighting to “Enhance White” and then press the [ENTER] key. This will enhance the white of the projected image. Instead of steps 1 and 2 above, you can also white enhance the projected image by pressing the [ f] key. To perform manual skew correction on the currently projected image NoteSkew correction automatically straightens the image of a document that is misaligned on the document stage of the document camera. Under its initial defaults, the YC Camera application is configured to perform skew correction automatically. You can also turn off auto skew correction. If you do, you can use the following procedure to adjust image alignment manually. This operation will affect only the image that is currently being projected. The projection image produced the next time you release the shutter will be projected in accordance with the settings on the YC Camera A pplication Setup Menu (page 46). 1.Press the [FUNC] key to display the YC Camera application function menu. 2.Use the [] key to move the high lighting to “Skew Correction” and then press the [ENTER] key. This will straighten the projected image. Instead of steps 1 and 2 above, you can also perform skew correction of the projected image by pressing the [Z ] key.
46 Configuring YC Camera Application Setup Menu Settings You can use the YC Camera setu p menu to configure various YC Camera application operation settings. To configure YC Camera application setup menu settings 1.Press the [MENU] key to display the setup menu. 2.Press the [ ] key to move the highlighting to “USB” and then press the [ENTER] key. 3.Press the [ ] key once to move the highlighting to “Setup” and then press the [ENTER] key. This will display the YC Camera application setup menu. 4.Use the [ ] and [ ] keys to select the menu item whose setting you want to change. 5.Press the [ ] or [ ] key to select the setting you want (so its button is 0). 6.Repeat steps 4 and 5 to configu re other settings, if you want. 7.After you are finished, press the [ESC] key to exit the setup menu. NoteAnytime you change the “White Enhancement” or “Skew Correction” setting, the new setting goes into effect from the next image you record with the document camera after exiting the setup menu. Other settings go into effect as soon as you exit the setup menu.
47 To restore all settings on the YC Camera application setup menu to their initial factory defaults 1.Press the [MENU] key to display the setup menu. 2.Press the [] key to move the highlighting to “USB” and then press the [ENTER] key. 3.Press the [ ] key once to move the highlighting to “Setup” and then press the [ENTER] key. This will display the YC Camera application setup menu. 4.Press the [ ] key to move the highlighting to “Initialize YC Camera Setup” and then press the [ENTER] key. This displays the di alog box shown below. 5.Use the [] key to select “Yes”. 6.To restore all the setting s to their initial defaults, press the [ENTER] key. To exit the operation without doing anything, press the [ESC] key instead of the [ENTER] key. 7.After you are finished, press the [ESC] key to exit the setup menu.
48 YC Camera Application Setup Menu Contents This section provides detailed explanations of all of the items included on the YC Camera application setup menu. The initial defaul t setting for each item is indicated by an asterisk ( *). Setting NameDescription Operation Mode Specifies whether recording of documents placed on the document stage of the document camera should be performed automatically or manually. Auto Capture*: Automatically records the image of a document whenever it is placed on the document stage. Manual Capture: Requires manual release of the shutter each time a document is placed on the document stage. Monitor Screen Orientation Switches the monitor screen orientation. Horizontal *: Records the document on the document stage horizontally. Vertical: Records the document on the document stage vertically. White Enhancement Specifies whether or not white enhancement should be performed on the projected image. Off*: Turns off white enhancement. On: Turns on white enhancement. Auto: The decision whether or not to perform white enhancement is made automatically in accordance with the image being recorded. Important!White enhancement cannot be performed while the “Skew Correction” setting is “Off”.
49 Skew Correction Specifies whether or not skew correction should be performed automatically on the projected image. On*: Turns on automatic skew correction. Off: Turns off automatic skew correction. Project Document Monitor Image Specifies whether or not the camera’s monitor image should be projected when a document is removed from the document stage. On *: Displays the monitor image. Off: Does not display the monitor image. Initialize YC Camera Setup Returns all YC Camera application setup menu items to th eir initial default settings. For details, see “To restore all settings on the YC Camera application setup menu to their initial factory defaults” on page 47. Setting NameDescription
50 Projecting the Screen Image of a Graphing Calculator You can connect a CASIO graphing calculator to the Data Projector using a USB cable and project the calculator’s screen image with the Data Projector. USB connection of the following CASIO graphing calculators is supported. fx-9860G Series To project the screen image of a graphing calculator 1.Set the graphing calculator up for data communication. Enter the LINK Mode, and configure the “Wak eup” and “Capture” settings as shown below. Be sure to configure these communication settings before you connect the calculator to the Data Projector. See the user documentation that comes with your calculator for details about configuring these settings. 2.Turn on the Data Projector. 3.Use the USB cable that came with the grap hing calculator to connect it to the Data Projector as illustrated below. This will project an image of the graphing calculator from the Data Projector. Important!If an hourglass figure appears in the image projected from the Data Projector when you connect the calculator, perform some operation on the calculator. This should cause the hourglass to disappear and enable normal projection. If the calculator does not operate properly af ter you connect it to the Data Projector, try disconnecting the USB cable from the calculator and then reconnecting it. If this does not correct the problem, disconnect the USB cab le from both the Data Projector and the calculator. Turn the Data Projector off and then back on again, and then re-connect the calculator. * The illustration shows the fx-9860G as an example. USB Cable