    Data
     
    T S TAT
    Thermostats
    Thermidistat
     
    TM
     
     Control
     
    Copyright 1999 Carrier CorporationTSTAT-3PD 
    The Carrier electronic thermostat 
    product line consists of programmable 
    and non-programmable air conditioner, 
    heat pump, and 2-speed models; a 
    programmable dual fuel model; and a 
    programmable/non-programmable 
    Thermidistat 
    TM
     
     Control. Carrier also 
    offers builderÕs thermostats in both air 
    conditioner and heat pump models. 
    These units feature non-mercury based 
    electronic controls built into a subtle, 
    slim plastic enclosure. They require no 
    battery back-up and the programmable/
    non-programmable models are not 
    power stealing. 
    FEATURES/BENEFITS
     
    BUILDERÕS THERMOSTATS
     
    Product Offering   
    Ñ 
    Non-programmable air conditioner and 
    heat pump models available.  
    Easy to Use   
    Ñ Rubber push buttons 
    provide easy changes to heating/cooling 
    mode operation, fan operation, and 
    desired temperature setting.  
    Manual Changeover   
    Ñ Allows 
    manual switches in system operation 
    when both heating and cooling are 
    needed on the same day. 
    NON-PROGRAMMABLE 
    THERMOSTATS
     
    Clean Design   
    Ñ Features soft, 
    responsive buttons and an easy-to-read 
    backlit Liquid Crystal Display (LCD).  
    Accurate, Reliable Temperature 
    Control   
    Ñ LCD shows current room 
    temperature at all times, and desired 
    temperature prompts upon demand.  
    Auto Changeover   
    Ñ Switches system 
    operation automatically when both 
    heating and cooling are needed on the 
    same day. It can be disabled if not 
    necessary in certain areas of the country.  
    Outdoor Temperature Display   
    Ñ 
    Allows a check of the temperature 
    outside before leaving home. (Optional 
    on heat pump and 2-speed models.)  
    Clean Filter Indicator   
    Ñ Tells when it 
    is time to clean the systemÕs Þlter.  
    Battery Free   
    Ñ Non-volatile RAM 
    chip requires no battery backup.  
    Equipment On Indicator   
    Ñ On all 
    non-programmable models, HEAT ON or 
    COOL ON indicator is displayed when the 
    heating or cooling equipment is operating.  
    Room Temperature Offset  
    Ñ Room 
    temperature may be deliberately offset by  
    BUILDERÕS MODEL THERMOSTAT
     
    * Standard Model (AC, HP)
     
    NON-PROGRAMMABLE THERMOSTAT
     
    * Standard Model (AC, HP, 2S)
     
    PROGRAMMABLE THERMOSTAT, DUAL FUEL,
    AND THERMIDISTAT
     
    TM
     
     CONTROL
     
    * Standard Model (AC, HP, 2S)
    * Dual Fuel Model (DF)
    * Thermidistat Control Model (RH) 
    						
    							 
    2 up to 5¡F in either direction to 
    accommodate end userÕs needs. 
    Perfect Complement  
    Ñ Completes 
    your Carrier total comfort system needs. 
    Limited Warranty  
    Ñ Standard 1-year 
    warranty available on all parts. 
    PROGRAMMABLE 
    THERMOSTATS
     
    Carrier programmable thermostats 
    possess the same features as non-
    programmable thermostats plus: 
    Comfort and Energy Savings  
    Ñ 
    Seven day programming, with 
    4 temperature changes provided per day, 
    means comfort when the family is at 
    home and savings through reduced 
    energy usage when the family is away 
    or asleep. 
    Easy to Use  
    Ñ Simple instructions are 
    located inside the thermostatÕs door. 
    Duplicate Programming  
    Ñ Copy 
    the comfort schedule from one day to 
    the next using the copy previous day 
    function. 
    Override Capability  
    Ñ Hold function 
    allows the regular schedule to be 
    bypassed with a temporary setting. 
    Battery-Free 
     Ñ Non-volatile RAM 
    chip requires no battery backup. 
    Program is retained in memory so 
    reprogramming is not required after 
    power loss. 
    Smart Recovery   
    Ñ Provides 
    consistent heating right on time as it 
    gradually adjusts indoor temperatures 
    before a scheduled change.  
    Timeguard   
    Ñ Equipment protection.  
    DUAL FUEL MODEL  
    The dual fuel thermostat can be used to 
    control a gas furnace and a heat pump. 
    This thermostat eliminates the need for 
    an interface control kit. The outdoor 
    temperature sensor is included. 
    THERMIDISTAT
     
    TM
     
     CONTROL
     
    CarrierÕs Thermidistat Control can 
    be used to control any equipment 
    application except zoning. It possesses 
    all the features and beneÞts of CarrierÕs 
    non-programmable and programmable 
    thermostats plus:  
    Enhanced Comfort   
    Ñ Allows  the 
    homeowner to accurately maintain the 
    desired temperature and humidity 
    settings in the home. By combining the 
    functions of a programmable thermostat 
    and a humidistat, the Thermidistat 
    Control provides temperature control, 
    humidity control, and dehumidiÞcation.  
    Humidity Control   
    Ñ The Thermidistat 
    Control accurately controls humidity level. 
    It humidiÞes during heating and 
    dehumidiÞes during cooling.  
    Automatic Humidity Adjustment   
    Ñ 
    When used with the outdoor temperature sensor, the Thermidistat Control 
    automatically adjusts the humidity 
    setting, reducing excess condensation 
    from forming on the windows.  
    Vacation mode   
    Ñ With a single touch 
    of a button, vacation mode adjusts all 
    comfort levels for optimum efÞciency 
    while the home is unoccupied Ñ or 
    restores the settings to normal upon return.  
    Smart Recovery   
    Ñ Provides consistent 
    heating and cooling right on time as it 
    gradually adjusts indoor temperatures 
    before a scheduled change.  
    Equipment On Indicator   
    Ñ When 
    the cooling equipment is operating, the 
    word COOL preceded by a small triangle 
    is displayed below the cooling set point. 
    When the heating equipment is 
    operating, the word HEAT preceded by a 
    small triangle is displayed below the 
    heating set point. If the equipment turn 
    on is being delayed, the triangle and the 
    word will ßash.  
    Non-Programmable Option   
    Ñ Offers 
    the same popular humidity control 
    beneÞts to consumers who do not need 
    the added beneÞts of programming. Nine 
    functional buttons, along with the UP and 
    DOWN buttons, make it easy to enter the 
    temperature and humidity set points. The 
    LCD is the largest display on the market 
    for a non-programmable thermostat. 
    Model number nomenclature
     
    ELECTRONIC THERMOSTATS
    T STAT
    THERMOSTAT01 
    QUANTITY AC
    AC – AIR CONDITIONING
    HP – HEAT PUMP
    2S – TWO SPEED/TWO STAGE
    DF – DUAL FUEL
    RH – RELATIVE HUMIDITY (THERMIDISTAT CONTROL)–B
    SERIES N
    P – PROGRAMMABLE
    N – NON-PROGRAMMABLE CC
    CC – CARRIER BRANDB – BUILDERS MODEL
    A99047
     
    As an ENERGY STAR 
    SM
     
     Partner, 
    Carrier Corporation has determined 
    that the programmable thermostats 
    and programmable Thermidistat 
    Control meet the ENERGY STAR 
    guidelines for energy efÞciency. 
    						
    							 
    3 
    Dimensions
    Non-Programmable ThermostatBuilders Model Thermostat
    Programmable Thermostat and Thermidistat Control
    5 13⁄16² 3 
    1⁄2²
    4 
    3⁄8²
    7 
    3⁄8²1 
    3⁄8²
    4 1⁄4²
     3⁄4²
    1 3⁄8²
    2 3⁄4²
     
    A99044 
    						
    							 
    4 
    Product data information
     
    Physical Characteristics
     
    BuilderÕs Models:
    Dimensions: See drawing
    Appearance: Plastic, designer white, textured, white rubber push buttons
    Non-Programmable/Programmable Models:
    Dimensions: See drawing
    Appearance: Plastic, eggshell color, textured
     
    Electrical Characteristics
     
    BuilderÕs Models:
    Input Volts/Amps: 24vac, 1 VA
    Non-Programmable/Programmable Models:
    Input Volts/Amps: 24vac, 5 VA
     
    Environmental Requirements:
     
    Operating Temperature/Relative Humidity: 32¡F (0¡C) to 104¡F (40¡C)/95% rh non-condensing
    Storage Temperature/Relative Humidity: Ð40¡F (Ð40¡C) to 134¡F (56¡C)/95% rh non-condensing
     
    Program SpeciÞcations:
     
    BuilderÕs Models:
    Temperature set point range: 50¡F (10¡C) to 90¡F (32¡C)
    Manual changeover
    Non-volatile memory
    Fahrenheit or Celsius selectable
    Power-stealing option on AC model only
    Selectable fan ON or OFF with auxiliary heating (HP model)
    Five-minute compressor timeguard
    Four cycles per hour maximum
    Auxiliary heat LED on heat pump models
    Non-Programmable Models:
    Temperature setpoint range: 40¡F (4¡C) to 90¡F (32¡C)
    Separate heat and cool setpoints
    Auto changeoverÑcan be disabled
    Clean Þlter reminder: installer adjustable
    Permanent memory
    Equipment On indicator
    Programmable Models:
    Temperature setpoint range: 40¡F (4¡C) to 90¡F (32¡C)
    Separate heat and cool setpoints
    Auto changeoverÑcan be disabled
    Clean Þlter reminder: installer adjustable
    Permanent memory
    Programming days: 7 day
    Programming periods: 4ÑWake, Day, Eve, Sleep
    Hold function
    Copy previous day function
    Humidity display and control (Thermidistat Control only)
    Equipment On indicator (Thermidistat Control only)
     
    Wiring Requirements:
     
    Power: 24vac nominal, 18- to 30-vac, 50/60 Hz
    Wiring: Standard 18 to 22 gage. 
    						
    							 
    5 
    Description
     
    BUILDERÕS MODEL THERMOSTATS 
    *  
    Variable-speed furnaces (58MVP) are not compatible with power stealing thermostat applications (i.e. no common wire connection). In order to use 
    this thermostat with variable-speed furnaces, a common wire  
    MUST 
     be applied. 
    ** 
     Do not use in zoning applications. 
    NON-PROGRAMMABLE ELECTRONIC THERMOSTATS
    PROGRAMMABLE ELECTRONIC THERMOSTATS 
    * 
     Do not use in zoning applications. 
    Thermostat accessories
     
    * 
    Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non-programmable air conditioner version and 
    builderÕs model thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. 
    The outdoor air temperature sensor  
    must 
     be 
     used with the dual fuel thermostat.
    The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
      This plate is designed to cover surrounding wall area located behind thermostat.
    à Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used 
    to replace a broken thermostat wire, or add an extra wire when needed. 
    PART NO. DESCRIPTION
    TSTATCCBAC01
     
    *
     
    Thermostat, Air Conditioner, Non-Programmable, 1-Stage Heat/1-Stage Cool, Manual Changeover, ¡F/¡C
     
    TSTATCCBHP01
     
    **
     
    Thermostat, Heat Pump, Non-Programmable, 2-Stage Heat/1-Stage Cool, Manual Changeover, ¡F/¡C
     
    PART NO. DESCRIPTION
    TSTATCCNAC01-B
     
    Thermostat, Auto Changeover, Non-Programmable, ¡F/¡C, 1-Stage Heat/1-Stage Cool
     
    TSTATCCNHP01-B
     
    Thermostat, Auto Changeover, Non-Programmable, ¡F/¡C, 2-Stage Heat/1-Stage Cool
     
    TSTATCCN2S01-B
     
    Thermostat, Auto Changeover, Non-Programmable, ¡F/¡C, 2-Stage Heat/2-Stage Cool
    in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
     
    PART NO. DESCRIPTION
    TSTATCCPAC01-B
     
    Thermostat, Auto Changeover, 7-Day Programmable, ¡F/¡C, 1-Stage Heat/1-Stage Cool
     
    TSTATCCPHP01-B
     
    Thermostat, Auto Changeover, 7-Day Programmable, ¡F/¡C, 2-Stage Heat/1-Stage Cool
     
    TSTATCCP2S01-B
     
    Thermostat, Auto Changeover, 7-Day Programmable, ¡F/¡C, 2-Stage Heat/2-Stage Cool
    in AC Mode, 3-Stage Heat/2-Stage Cool in HP Mode
     
    TSTATCCPDF01-B
     
    *
     
    Dual Fuel Thermostat, Includes Outdoor Air Temperature Sensor
     
    TSTATCCPRH01-B
     
    *
     
    Thermidistat Control Ñ Non-Programmable/Programmable Thermostat with Humidity Control
    (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) 
     
    PART NO. DESCRIPTION
    TSTATXXSEN01-B
     
    *
     
    Outdoor Air Temperature Sensor
     
    TSTATXXNBP01 
     
    Backplate for Non-Programmable Thermostat
     
    TSTATXXPBP01 
     
    Backplate for Programmable Thermostat and Thermidistat Control
     
    TSTATXXBBP01 
     
    Backplate for BuilderÕs Model Thermostat
     
    TSTATXXCNV10à
     
    Thermostat Conversion Kit (4 to 5 Wire) Ñ 10 Pack 
    						
    							 
    6 
    Thermostat and Thermidistat Control application
     
    NON-PROGRAMMABLE THERMOSTAT USAGE 
    * 
    Model HP thermostat must be Þeld converted to air conditioner operation.
      Must use Programmable Dual Fuel Thermostat or Thermidistat Control in this application.
    à Dual Fuel operation controlled by heat pump when using Model 2S Thermostat. 
    Non-Programmable Models
     
    The TSTATCCNAC01-B Thermostat provides single-stage, non-programmable heat/cool temperature control for 24-vac 
    heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F or ¡C.
    The TSTATCCNHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, non-programmable 
    temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F 
    or ¡C. Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. 
    This model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric 
    heat.
    The TSTATCCN2S01-B Thermostat provides versatile multiple stage, non-programmable heat/cool temperature control for 
    24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F or ¡C. Thermostat is 
    designed for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 2-stage 
    cooling and 3 stages of heat (third-stage controlling auxiliary electric heat). This model can easily be converted from heat 
    pump operation to air conditioning operation requiring 2 stages of cooling and 2 stages of heating.
     
    PROGRAMMABLE THERMOSTAT USAGE 
    * 
    Model HP thermostat must be Þeld converted to AC operation.
      For use with special 3-stage electric heat setup.
    à Dual Fuel operation controlled by heat pump when using Model 2S Thermostat. 
    Programmable Models
     
    The TSTATCCPAC01-B Thermostat provides single-stage, 7-day programmable heat/cool temperature control for 24-vac 
    heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F or ¡C.
    The TSTATCCPHP01-B Thermostat provides versatile 2-stage heating and single-stage cooling, 7-day programmable 
    temperature control for 24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F 
    or ¡C. Thermostat comes factory set to operate as a heat pump model with second-stage controlling auxiliary electric heat. 
    This model can easily be converted from heat pump operation to air conditioning operation requiring 2 stages of gas or electric 
    heat.
    The TSTATCCP2S01-B Thermostat provides versatile multiple stage, 7-day programmable heat/cool temperature control for 
    24-vac heating-cooling systems with auto changeover. Temperature display can be selected to read ¡F or ¡C. Thermostat is 
    designed primarily for 2-speed compressor bearing units. Thermostat comes factory set to operate as a heat pump model with 
    2-stage cooling and 3-stages of heat (third-stage controlling auxiliary electric heat). This model can also perform Intelligent 
    Heat staging with FK, FV, and 40FKA fan coils (special heaters and setup required) using a single-speed heat pump with 3-
    stages auxiliary electric heat. In addition, this model can easily be converted from heat pump operation to air conditioning 
    operation requiring 2 stages of cooling and 2 stages of heating (e.g. gas or electric heat).
     
    INDOOR UNITOUTDOOR UNIT
    Air Conditioner Heat Pump
    1 Speed 2 Speed 1 Speed 2 Speed
    1-Stage Furnace
     
    Model AC or HP
     
    *
     
    Model 2S   Model 2Sà
     
    2-Stage Furnace
     
    Model AC or HP
     
    *
     
    Model 2S   Model 2Sà
     
    Typical Fan Coil
     
    Model AC or HP
     
    *
     
    Model 2S Model HP Model 2S
     
    FK, FV, 40FKA Series Fan Coil
     
    Model AC or HP
     
    *
     
    Model 2S Model HP Model 2S
     
    INDOOR UNITOUTDOOR UNIT
    Air Conditioner Heat Pump
    1 Speed 2 Speed 1 Speed 2 Speed
    1-Stage Furnace
     
    Model AC or HP
     
    *
     
    Model 2S Model DF Model DF or 2Sà
     
    2-Stage Furnace
     
    Model AC or HP
     
    *
     
    Model 2S Model DF Model DF or 2Sà
     
    Typical Fan Coil
     
    Model AC or HP
     
    *
     
    Model 2S Model HP Model 2S
     
    FK, FV, 40FKA Series Fan Coil
     
    Model AC or HP
     
    *
     
    Model 2S Model HP or 2S  Model 2S 
    						
    							 
    7 
    Programmable Dual Fuel Model
     
    The TSTATCCPDF01-B Thermostat provides single-stage or multiple-stage dual fuel operation, 7-day programmable heat/
    cool temperature control for 24-vac systems with auto changeover. Temperature display can be selected to read ¡F or ¡C. The 
    Dual Fuel Thermostat is designed with separate lockout temperatures for the furnace and the heat pump. The furnace is 
    prevented from operating above its lockout temperature and the heat pump is prevented from operating below its lockout 
    temperature. Thermostat comes factory set to operate single-speed equipment, but is easily conÞgured to match multiple stage 
    equipment combinations. This model requires use of the Outdoor Air Temperature Sensor accessory, which is included with 
    the Dual Fuel Thermostat. Using the dual fuel thermostat eliminates the need for an interface control.
     
    THERMIDISTAT CONTROL USAGE 
    * 
    The Thermidistat Control may be used in all applications but must be Þeld conÞgured for speciÞc application. 
    Thermidistat Control
     
    The TSTATCCPRH01-B Thermidistat Control provides single-stage or multiple-stage equipment operation, 7-day 
    programmable heat/cool temperature control for 24-vac systems with auto changeover. It controls both humidiÞcation and 
    dehumidiÞcation and can be used to control heat pumps, air conditioners, or dual fuel applications. Temperature display can 
    be selected to read ¡F or ¡C. The Thermidistat Control is designed primarily as an extension of the programmable thermostat 
    line to provide humidify and dehumidify outputs in controlling humidity. It can also be Þeld conÞgured to be non-
    programmable. Humidify outputs connect directly to 24-v humidiÞers. Dehumidify outputs connect directly to variable-speed 
    furnaces or fan coils that have dehumidiÞcation capabilities. To achieve full beneÞts, this model requires use of the Outdoor 
    Air Temperature Sensor accessory, which is included with the Thermidistat Control.
    The Thermidistat Control comes packaged with the 40FKA for Comfort Heat.
     
    INDOOR UNITOUTDOOR UNIT
    Air Conditioner Heat Pump
    1 Speed 2 Speed 1 Speed 2 Speed
    1-Stage Furnace
     
    Model RH
     
    *
     
    2-Stage Furnace
    Typical Fan Coil
    FK, FV, 40FKA Series Fan Coil 
    						
    							 
    Copyright 1999    Carrier Corporation  
    ¥ 
     Indianapolis, IN 46231    2-99 
    Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 
    Book 1 4 Page 8 Catalog No. 02TS-TA3 Printed in U.S.A. PC 101 Form TSTAT-3PD
    Tab misc miscReplaces: TSTAT-2PD 
    Operational information
     
    Five-minute compressor timeguard
     
    This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by 
    simultaneously pressing the FAN mode button and INCREASE TEMPERATURE (UP) button.
     
    Fifteen-minute cycle timer
     
    This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its 
    function is to assure that equipment is not cycled more than 4 times per hr. This timer is defeated for 1 cycle when the desired 
    temperature is manually changed. It can also be defeated for 1 cycle by simultaneously pressing the FAN button and the 
    INCREASE TEMPERATURE button.
     
    Fifteen-minute staging timer
     
    In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 15 
    minutes. This timer is defeated if temperature error is greater than 5¡F (usually due to a large change in desired temperature).
     
    Minimum on time
    In normal operation, when a stage turns on, it will not turn off for a minimum of 3 minutes (2 minutes on BuilderÕs model).
    Heat/Cool set points (desired temperature)
    A minimum difference of 2¡ is enforced between heating and cooling desired temperatures. This is done by allowing one 
    setting to ÒpushÓ the other, to maintain this difference. (Thermidistat Control is adjustable.) BuilderÕs thermostats are 
    controlled by a single set point.
    Equipment on indicators (Non-Programmable models)
    When cooling equipment is ON, a COOL ON icon is displayed above the room temperature display. When heating equipment 
    is ON, a HEAT ON icon is displayed above the room temperature display.
    Equipment on indicators (Thermidistat Control)
    When cooling equipment is ON, a COOL icon preceded by a small triangle is displayed below the cool set point. While 
    cooling equipment turn on is delayed by a staging or cycle timer, the triangle and the word COOL will ßash. The same is true 
    for the HEAT icon and its preceding triangle located under the heat set point. The 2 triangles are also used to indicate the state 
    of the humidify and dehumidify outputs. See next section.
    Humidify/dehumidify output on indicators (Thermidistat Control)
    Within humidity select screen (selected by Humidity button and indicated by ÒhuÓ or ÒdhuÓ on clock display), the triangle 
    under humidity set point will be on while humidify output is on. The triangle under dehumidify set point will be on while 
    dehumidify output is active (turned off, because this output is reverse logic).
    Auto changeover
    When auto changeover mode is selected, a change from heat to cool (or vice versa) will not occur until an opposite mode 
    demand has existed for 20 minutes. If set point is changed, the 20 minute requirement is deleted. Auto changeover mode can 
    be disabled. BuilderÕs thermostats are manual changeover.
    Emergency heat mode
    When thermostat is controlling a heat pump and emergency heat is selected, all Y signals are locked out, and W becomes 
    energized upon a call for heat.
    Smart Recovery (Programmable models)
    With Smart Recovery selected, transition out of setback begins a Þxed time period before selected recovery time and gradually 
    adjusts room temperature so that the desired temperature will be achieved at selected recovery time. 
    Room Temperature Offset (All models)
    Room temperature may be deliberately offset by up to 5¡F in either direction.
    Maximum On/Off Deadband
    Maximum sensed temperature difference between ON and OFF is 0.8¡F for BuilderÕs thermostats and 0.6¡F for all other 
    models. 
    						
    All Carrier manuals Comments (7434)

    Related Manuals for Carrier Thermostat Tstatccpdf01b Manual