Carrier Microlink 3 Manual
Here you can view all the pages of manual Carrier Microlink 3 Manual. The Carrier manuals for Trailer Refrigeration are available online for free. You can easily download all the documents as PDF.
Page 1
Please circulate this newsletter to all of your support personnel Carrier Transicold Division • P.O. Box 4805 • Syracuse, New York 13221 • +1 315-432-7688 • Fax +1 315-432-7698 AN EXCHANGE OF TECHNICAL INFORMATION ABOUT CARRIER TRANSICOLD CONTAINER PRODUCTS VOLUME 9 NUMBER 1 1st Quarter 2004 Inside This Issue Te c hTi p Software Release Update F3 Fuse / Economizer Solenoid Valve Coil Te c hFact Manual Defrost High Pressure Switch Selection of Oil Filter Lower Vent Positioning Sensor...
Page 2
Feature Article MicroLink 3 Carrier Transicold is proud to announce its latest edition to the microprocessor family, the ML3 controller. This new controller will have all the same capabilities as the previous ML2i controller, as well as some new enhancements. Some of these enhancements are listed below. • Increased I/O; Additional internal relays allows for the added I/O capacity and future growth. • Enhanced battery charging, this will shorten the time required to charge the battery for recording...
Page 3
Feature Article - MicroLink3 (cont) Software Card The ML3 controller will require a new type of programming card. The new type is referred to as a PCMCIA card. Although there are many versions of cards available throughout the world, Carrier Transicold has selected one that fits its application and is guaran- teed to work properly. The new card part number is 12-00594-XX. Carrier Transicold only supports the use of this card. This card can hold the configuration and operation software for all 5XX...
Page 4
To program Operational Software into the controller: 1. Turn Power off 2. Insert software/programming PCMCIA card containing the following (example) files: •menuDDMM.ml3, this file allows the user to chose which file/program to upload into the controller. •cfYYMMDD.ml3, multi-configuration file •recp51XX.ml3, controller software program for recip units. •scrl53XX.ml3, controller software program for scroll units. 3. Turn unit Power On. Displays will show: ruN COnFG 4. Press the UP or DOWN...
Page 5
Te c hFact High Pressure Switch In December 2003, Carrier Transicold began factory installing a new High Pressure Switch with an internal snubber, P/N 12-00309-06, on all Container 69NT40-511 (non-Scroll) units. The new switch supercedes the old style switch, P/N 12-00309-03 which required the use of a separate snubber elbow. The new switch can be used on all non-Scroll units equipped with an OEM High Pressure Switch. When installing the new style switch in a unit that currently has the old style...
Page 6
Te c hFact Auto Defrost Starting with software revisions 5127 (Recip Units), Carrier Transicold introduced the Auto Defrost user selectable option. This option is an optimal way to ensure proper airflow and lower power consumption. The option has been added to the Defrost Interval selec- tion (code select 27). When scrolling through the selection you will now have the following options, 3, 6, 9, 12, 24 and the new option AUTO (some units may be configured to allow defrost to be disabled altogether;...
Page 7
Te c hFact Selection of Oil Filter There is some confusion in the field regarding the cor- rect oil filters to use in Carrier generator sets. In part, this has come about with technological improvements in the synthetic filter media. The full flow and the bypass options are now combined into the same filter (detailed in the 4th Quarter 2003 TechLine). Below should assist in identifying the correct filter to be used in the 69RG and 69UG units. Units equipped with dual filter housings (oil bypass...
Page 8
www.container.carrier.comEmergency 24 -Hour Technical Assistance 800-668-6283 (800-ONTO-CTD) email: [email protected] Please circulate this newsletter to all of your support personnel P. Hoover Lower Vent Positioning Sensor (cont) 4. Carefully reposition the slide onto the air make-up panel (gear is engaged with rail and gear did not move) 5. Position slide panel to full closed position. 6. Code select 45 will automatically display. Press the Enter key and hold for 5 seconds. 7....
All Carrier manuals