Page 51
T--311 4-5 Insulated Clamp Figure 4-- 13 Hose/Harness Clamped to Wall At this time the evaporator can be mounted. Refer to Section 2 for the proper procedures for installing a rear mounted evaporator assembly. 12. You may now make the appropriate connection to the evaporator. Proper hose to fitting clamping is critical. Do not attempt to attach any hose or fitting until you have familiarized yourself with Carrier Transport Air Conditioning Quick-Click hose/fitting crimping procedures. 4.3 EVAPORATOR HOSE...
Page 52
T--3114-6 On many of the larger buses there are heater hose lines with covers running the length of the bus floor. On most applications there is enough room inside the heater hose covers to route the hose, harness, and drain line behind the heater hose. Extreme care must be taken so as not to drill into, cut, or kink the heater lines. This type routing takes a little more time, but makes for a much neater installation. 5. Drill a 3/16 inch pilot hole in the center of where you are going to drill the two...
Page 53
T--311 4-7 Figure 4-- 15 Hose Routing (Chassis) Figure 4-- 16 Hose Routing (Chassis) Figure 4-- 17 Hose Routing (Chassis) Figure 4-- 18 Hose Routing (Chassis) Figure 4-- 19 Hose Routing (Chassis & Condenser) 4.6 CONDENSER HOSE ROUTING Always keep hose capped until ready to connect to a system component.When mounting hose in the condenser area, secure the hose in a manner so that the weight of the hose is not on the condenser fittings.
Page 54
T--3114-8 Always try to leave a service loop in the hose to relieve stress from the condenser fitting and for ease of serviceability. When making condenser connections, always use caution as you start the fitting onto the condenser. Lubricate the fitting and “O” Ring with mineral oil before making the connection. Secure hoses in the condenser area with insulated P-Clamps (see Figure 4-- 19). Properly clamping a fitting to the refrigerant hose is very important. Do not attempt to attach any hose or...
Page 55
T--311 4-9 Table 4-1 STANDARD TORQUE REQUIREMENTS SIZETUBE O.D. *FLAREO-RINGTHREAD ** STEEL TUBINGALUM. TUBING 41/4 inch (.250)11-13 ft./lbs.30-35 ft./lbs.5-7 ft./lbs.7/16 53/8 inch (.375)15-17 ft./lbs.30-35 ft./lbs.8-10 ft./lbs9/16 63/8 inch (.375)18-20 ft./lbs.30-35 ft./lbs.11-13 ft./lbs5/8 81/2 inch (.500)36-39 ft./lbs.30-35 ft./lbs.15-20 ft./lbs3/4 105/8 inch (.625)52-57 ft./lbs.30-35 ft./lbs.21-27 ft./lbs7/8 123/4 inch (.750)71-79 ft./lbs.30-35 ft./lbs.28-33 ft./lbs1-1/16 *The tube O.D. is measured...
Page 58
4--12 T--311 Figure 4-24 Evaporator, Skirt Monuted Condenser and Compressor (AC-- 322, -- 332, -- 442) FILTER DRIER
Page 59
4--13 T--311 Figure 4-25 Evaporator, Skirt Monuted Condenser Compressor and Aftermarket InDash (AC-- 4431) FILTER DRIER
Page 60
4--14 T--311 Figure 4-26 EM--3 Evaporator, (2) Skirt Monuted Condensers and TM -- 31 Compressor (AC-- 882, -- 883) FILTER DRIER FILTER DRIER