    							78-8130-6150-0 Rev G 61
    24. Receiver Specifications
    Item Specification
    Modes Directional Peak
    Directional Null
    Special Peak 
    Induction Peak
    Frequency Response:
     Active 577 Hz
    8 kHz
    33 kHz
    200 kHz
      Passive 31.5 kHz (CATV)
    9 – 30 kHz (LF)
      Power 50 Hz, 5th and 9th harmonic of 50 Hz
    60 Hz, 5th and 9th harmonic of 60 Hz
    (100 / 120 Hz) rectified power
     Auxiliary 333 Hz
    512 Hz
    560 Hz
    User Defined Frequencies Four
    Display LCD
    Gain Control Manual and Automatic
    Weight w/batteries 4–5 lbs. (1.8–2.3 kg) (model dependent)
    Battery Qty. and size 8 AA (LR6)
    Battery Life 30 hours average
    Depth Accuracy ±2% ± 2 in. (5 cm) for 0–60 in. (0-1.5 m)
    ±6% ± 2 in. (5 cm) for 60–120 in. (1.5–3.0 m)
    ±10% ± 2 in. (5 cm) for 120–180 in. (3.0 m–4.5 m)
    Depth Range 0–360 in. (0–914 cm)
    Marker depth accuracy  ± 15% ± 2 in. (5 cm)
    Maximum Program Range  
    3M
    ™ iD Markers
     Near-Surface
      Ball Marker
     Full-Range  
    6 in (15 cm)
    12 in (30 cm)
    24 in (61 cm) 
    						
    							 62 78-8130-6150-0 Rev G
    ItemSpecification
    Read Range 3M
    ™ iD Markers
     Near-Surface
      Ball Marker
     Full-Range  3 ft (0.9 m)
    5 ft (1.5 m)
    8 ft (2.4 m)
    Detection Depth 3M Non-iD (Passive) 
    Markers
      Near Surface
      Ball Marker
     Mid-Range
     Full-Range  
    2 ft (0.6 m)
    5 ft (1.5 m)
    6 ft (1.8 m)
    8 ft (2.4 m) 
    						
    							78-8130-6150-0 Rev G 63
    25. Transmitter Specifications
    Item Specification
    Trace Mode  577 Hz
    8 kHz
    33 kHz
    200 kHz
    Fault Mode  
    (2273M models only) 10/20 Hz - Fault signal 
    577 Hz / 33 kHz -Trace signal
    Note: The fault locating limit is 2.0MΩ
     although the transmitter's ohmmeter 
    mode can display a fault resistance up to 10MΩ .
    Tone Mode  577 Hz and 200 kHz pulsing at 8 Hz 
    Induction Mode  8 kHz (only available on 12 Watt Transmitter) 
    33 kHz
    200 kHz
    Output Power 
    (in Direct Connect mode) 3 Watt Transmitter Model 
    Normal setting: 0.5 W
    High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz
    5 Watt Transmitter Model 
    Normal setting: 0.5 W
    High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz
    Maximum setting: 5 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz
     
    (with external DC power source)
    12 Watt Transmitter Model 
    Normal setting: 0.5 W
    High setting: 3 W @ 577 Hz, 8 kHz, 33 kHz; 1 W @ 200 kHz
    Maximum setting: 12 W @ 577 Hz, 8 kHz; 10 W @ 33 kHz; 1 W @ 200 kHz 
    (with external DC power source)
    Output Voltage (Maximum) 70 Vrms
    Output Protection 240 Vrms
    Weight w/batteries  w/ alkaline batteries only: 5.2 lbs (2.4 kg)
    w/ rechargeable battery (2200RB) and alkaline batteries (5W and 12W 
    transmitters only): 9.2 lbs (4.2 kg)
    Battery Qty. and size  For Normal and High Output Power: 6 "C" size, Alkaline (LR14)
    For Maximum Output Power: Rechargeable Battery (2200RB), 12V-6AH, 
    Sealed Maintenance-Free Lead (Pb)-Acid Battery   
    (See safety information below.)
    Battery Life  Normal Output Power level: 50 hours typical
    High Output Power level: 10 hours typical
    Typical transmitter specified battery life (listed above) is increased by 40% 
    when using the 2200RB Rechargeable Battery (12 volt). Using the 2200RB 
    bypasses the alkaline batteries.
    Maximum Output Power level: 4 hours typical (Maximum Output Power level 
    achieved using 2200RB Rechargeable Battery.) 
    External DC Power  9–18 V DC 
    Rechargeable Battery fuse 5 Amp / 32 Volt
    Littelfuse MINI
    ® Blade # 0297005
    Cigarette Lighter Adapter 
    Cable fuse 4 Amp / Fast Blow 250V 
    						
    							 64 78-8130-6150-0 Rev G
    26. Environmental and Regulatory Specifications
    Item Specification
    Standard IP54
    Regulatory FCC compliant, FCC Part 15
    Operating Temperature -4°F to 122°F (-20°C to 50°C)
    Storage Temperature -4°F to 158° F (-20°C to 70°C)
    27. Rechargeable Battery Information
    UN2800 classification as “Batteries, wet, Non-Spillable, and electric storage” 
    as a result of passing the Vibration and Pressure Differential Test described in 
    DOT [49 CFR 173.159(d) and IATA/ICAO [Special Provision A67].
    ! CAUTION
    To reduce the risks associated with environmental contamination and possi\
    ble injury:
    The 12W transmitter utilizes the 2200RB rechargeable battery for the Maximum Output Power 
    level. This is a maintenance-free sealed lead (Pb)-acid battery.
    •  Replace the battery if the acid solution leaks.
    •  The batteries are not serviceable.
    •  Do not disassemble batteries.
    •  Do not remove vent caps.
    •  Do not rest tools or cables on batteries.
    •  Store lead-acid batteries with adequate ventilation.
    •  Do not heat batteries above 140°F (60°C)
    •  Never recharge batteries in an unventilated, enclosed space.
    •  Spent batteries must be treated as hazardous waste. Dispose of batteries and electronic 
    components in accordance with all regulations.
    •  Do not incinerate batteries.
    •  Always remove/disconnect batteries when not in use or storing for long periods of time. 
    						
    							78-8130-6150-0 Rev G 65 
    						
    							Important Notice
    All statements, technical information and recommendations related to 3M Products are ba\
    sed on information 
    believed to be reliable, but the accuracy or completeness is not guaranteed. Before using the 3M Product, you 
    must evaluate it and determine if it is suitable for your intended appli\
    cation. Because conditions of Product 
    use are outside of our control and vary widely you assume all risks and liability associated with such use. Any 
    Product-related statements not contained in current 3M publications, or any contrary statements contained in 
    your purchase order, shall have no force or effect unless expressly agreed to in writing by \
    an authorized officer  
    of 3M.
    Limited Product Warranty
    3M Locators (except accessories), will conform to 3M's published specifications and will be free from def\
    ects 
    in material and manufacture for a period of twelve (12) months from th\
    e date of purchase. Dry cell batteries 
    included in any of 3M's products are warranted only to the extent the ba\
    ttery manufacturer determines such 
    batteries are covered by its warranty. Locating accessories are warranted for ninety (90) days after purchas\
    e. 
    3M's obligations and liability under this warranty are limited to repair\
    ing, replacing or refund of the purchase 
    price, at 3M's option, any of 3M's products which, after normal and proper usage, are determined by 3M to be 
    defective. This warranty does not extend to any of 3M's products which have been su\
    bjected to misuse, neglect, 
    accident or improper applications, nor shall it extend to products which have been repaired or substantial\
    ly 
    altered outside 3M's manufacturing or repair facility, nor to any associated instruments, equipment or apparatus. 
    Before utilizing any of 3M's products, BUYER should determine the suitability of the product for BUYER'S 
    intended use. 3M MAKES NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED 
    WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no case shall 3M be 
    liable for any special, or consequential damages based upon breach of warranty, breach of contract, negligence, 
    strict liability or any other legal theory. This limitation does not apply to claims for personal injury.
    Special Condition: Shipments into authorized distributor/supplier locations will have an a\
    dditional ninety (90) day 
    warranty period.
    3
    Electrical Markets Division6801 River Place Blvd.
    Austin, TX 78726-9000
    1-800-200-0265  
    FAX: 1-877-601-1305
    www.3M.com/dynatel  Please Recycle. Printed in USA.
    © 3M 2014. All Rights Reserved.
    78-8130-6150-0 Rev G
    This is the EU symbol f
    or equipment that is covered 
    under the W aste from Electr ical and Electronic 
    Equipment (WEEE) directiv e per CENELEC 
    Specification 5041.  It indicates that cert ain products 
    should not be discarded in the trash,  but rather 
    should be recycled.   This applies to all electronic 
    pluggab le and batter y powered product s.This is the EU symbol for equipment that is covered under the Waste 
    from Electrical and Electronic Equipment (WEEE) directive per CENELEC \
    Specification 5041. It indicates that certain products should not be 
    discarded in the trash, but rather should be recycled. This applies to all 
    electronic pluggable and battery powered products.
    3M and Dynatel are trademarks of 3M Company.
    ArcPad is trademark of Environmental Systems Research Institute, Inc. (\
    ERSI).
    MINI and Littlefuse are trademarks of Littlefuse, Inc. 
    						
    All 3M manuals Comments (0)

    Related Manuals for CablePipeFault Advanced Locator 2250M2273M Series User Manual