Bosch Dhi 655 F Manual
Here you can view all the pages of manual Bosch Dhi 655 F Manual. The Bosch manuals for Extraction System are available online for free. You can easily download all the documents as PDF.
Page 1
DHI 645 F / DHI 655 F a Internet: http://www.bosch-hausgeraete.de Bosch Info-Team: de Tel. 01 80/5 30 40 50 (E0,12/Min. DTAG) de Gebrauchs- und Montageanleitung en Operating and installation instructions fr Mode d’emploi et notice de montage nl Gebruiksaanwijzing en montagevoorschrift it Istruzioni d’uso e per il montaggio esInstrucciones de uso y de montaje pt Instruções de serviçio e de montagem
Page 2
2 Abb. 1 GAS ELEKTRO GAZ ELECTR. KAASU ELETT. GASS EL. deSeite03–15 enpage 16 – 28 frpage 29 – 41 nlpagina 42 – 54 itpagina 55 – 67 espágina 68 – 80 ptpágina 81 – 93
Page 3
16 Operating modes This can be achieved if the combustion air is able to flow through non-lockable openings, e.g. in doors, windows and in conjunction with an air supply/air-intake wall box or by other technical procedures such as reciprocal interlocking. If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the...
Page 4
17 Before using for the first time Important notes: ❑The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. ❑This extractor hood complies with all relevant safety regulations. Repairsshould be carried out by qualified technicians only. Improper repairs may put the user at considerable risk. Do not flambé food directly under the extractor hood. Risk of grease filter catching fire due !to...
Page 5
18 Operating the extractor hood Cooking vapours are best eliminated by: ❑ Switching on the extractor hood when you start cooking. ❑ Only switching off the extractor hood a few minutes after you have finished cooking. Fan on / offLight on / off Intensive setting Fan settings Fan on / off Intensive settingReset button with saturation display for grease filter Fan settings Light on / off Switching off: The extractor hood can be switched off in various ways. Switch-off 1: ❑ Sliding switch to 0 – switch...
Page 6
19 4.Clean the filters. 5.Insert the clean filters back into the hood. 6. Cancel the in the display. ❑Press the button. Grease filters: Metal-mesh filters are used to trap the grease particles in the cooking vapours. The filter mats are made from non- combustible metal. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Clean the metal-mesh grease filters at regular intervals to prevent the...
Page 7
20 3.Engage the catches at both sides. 4.Insert the metal-mesh grease filters (see ”Removing and inserting the metal-mesh grease filters”). Removing the filter: Warning: The halogen bulbs must be switched off and cool. 1.Remove the metal-mesh filters. 2.Depress the catches on both sides of the filter and remove the activated carbon filter. 3. Replacing the activated carbon filter: ❑A replacement filter can be obtained from any authorized dealer (see optional accessories). ❑Use original filters only. This will...
Page 8
21 Cleaning and care Isolate the extractor hood by pulling out the mains plug or switching off the fuse. ❑When cleaning the grease filters, remove grease deposits from accessible parts of the housing. This prevents the risk of fire and ensures that the extractor hood continues operating at maximum efficiency. ❑Clean the extractor hood with a hot soap solution or a mild window cleaner. ❑Do not scrape off dried-on dirt but wipe off with a damp cloth. ❑Do not use scouring agents or abrasive sponges. ❑Note:...
Page 9
22 Important information Installation Instructions: The installation of the extractor hood above gas cooking devices, at a minimum height of650 mm – Fig. 1 – is permitted provided that the following nominal heat loads (Hs) are not exceeded: ❑ Gas cookers Load of one hotplatemax. 03.0 kW Load of all hotplates max. 08.3 kW Load of the oven max. 03.9 kW ❑ Gas hobs Load of one hotplatemax. 03.9 kW Load of all hotplates max. 11.3 kW ❑ Gas ceramic hotplate The nominal heat...
Page 10
23 Prior to installation Exhaust-air mode The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. DExhaust air must not be discharged via a smoke or exhaust gas flue which is already in use or via a shaft which is used for ventilating rooms in which fireplaces are located. Discharge exhaust air in accordance with official and statutory regulations (e.g. national building regulations). Discharge of air into smoke or exhaust air flues which are...