Page 11

Replacing the HEPA filter cartridge
The HEPA filter cartridge should be 
replaced every six months or if suction 
is declining. More or less frequent 
replacing may be required based on 
individual vacuuming habits and types of 
debris picked up.
Note: To have the benefits of the 
Airetight
™ HEPA System, you must 
use the BISSELL HEPA filter cartridge.
1. To remove the HEPA filter cartridge, 
push down on the filter door latch and 
pull door away from the cleaner.
2. Lift the tab at the top of the HEPA...

Page 12

Clearing clogs
Low suction or poor pickup may be due to 
a clog in the vacuum cleaner. If you notice 
a change in the sound of the motor or a 
reduction in the spinning action in the dirt 
container, check for a clog.
If there is no suction or if suction is reduced 
at the hose, follow these steps to check for 
and clear the clog:
1.  Unplug cleaner from electrical outlet.
2.  Check the foam filter and clean as 
necessary (see cleaning your foam filter 
on page 10).  
3.  Check the HEPA filter and...

Page 13

Clearing clogs continued
If suction is normal at the hose, follow these steps 
to check for and clear the clog for floor cleaning:
1.  Check diverter area at back of machine for 
diverter position and clogs. When the hose 
wand is inserted in the base, the diverter 
should be down. If a clog is visible near the 
diverter, the plastic cover may be removed to 
clear the clog by removing the 7 screws as 
shown in illustration 8b above.
2.  Check the foot hose for clogs (2a). If you are 
not able to tell...

Page 14

14www.bissell.com 800.237.7691
Maintenance and care
Brush reset
If something becomes lodged in the foot and the 
brush shuts off, turn the cleaner off and unplug 
from the outlet. Remove the obstruction. The 
brush will automatically reset when the cleaner 
is plugged in and turned back on.
Brush maintenance
The rotating brush should be checked regularly 
for accumulating debris that might reduce the 
cleaning performance of your vacuum.
1.  Unplug cleaner from electrical outlet.
2.  Recline the handle...

Page 15

15www.bissell.com 800.237.7691
Changing the light bulb
1.  Unplug cleaner from electrical outlet.
2.  Recline handle for easier access to light bulb 
and remove screw to lift off lens.
3.  Remove the bulb by grasping bulb and pull-
ing straight out of the socket. Install the new 
bulb by pushing gently into the socket until 
the bulb snaps into place.
TurboBrush maintenance
The TurboBrush should be checked regularly for 
clogs or debris wrapping around the brush.
1.  Remove tool from hose or front of...

Page 16

16www.bissell.com 800.237.7691
Troubleshooting
Vacuum cleaner won’t turn on
Possible causes  Remedies
1.  Power cord not plugged in 1.  Check electrical plug
2.  Blown fuse/tripped breaker 2.  Check/replace fuse or reset breaker
3.  Thermal protector activated 3.  Allow cleaner to cool for 30 minutes, see 
     pg.  13
4.  Handle not fully attached 4.  Remove handle and reinstall
Brush not rotating
Possible causes   Remedies
1.  Brush switch turned to “Off” 1.  Make sure brush switch is in “On” position...

Page 17

Troubleshooting
17www.bissell.com 800.237.7691
Vacuum cleaner is difficult to push
Possible causes  Remedies
1.  Incorrect height setting 1.  Turn dial to higher setting
Visible dust escaping from cleaner
Possible causes  Remedies
1.  Filter tray missing or not installed properly 1.  Check filter tray to make sure it is 
     fully  inserted
2.  Foam filter missing or not installed properly  2.  Check foam filter for correct installation
3.   HEPA filter cartridge missing or not installed properly 3....

Page 18

18www.bissell.com 800.237.7691
For information about repairs or replacement parts, or questions about your warranty, call:
BISSELL Consumer Services
1-800-237-7691
 
Monday - Friday    8 a.m. — 10 p.m. EST
Saturday    9 a.m. — 8 p.m. EST
Or write:
BISSELL HOMECARE, INC
PO Box 3606
Grand Rapids  MI 49501
ATTN: Consumer Services
 
Or visit the BISSELL website - www.bissell.com
When contacting BISSELL, have model number of cleaner available.
Please record your Model Number: ___________________
Please record...

Page 19

19www.bissell.com 800.237.7691
You may purchase parts from your retailer, by calling BISSELL Consumer Services or by 
visiting our website. Below is a list of common replacement parts*. While not all of these 
parts may have come with your specific model, they are available for purchase if desired.  
Please note, all attachments may not store on board your vacuum.
Item  Part No.  Part Name
1  3282   HEPA Filter Cartridge
2 203-1374 Foam Filter
3 203-1362 TurboBrush
4  203-1372  TurboBrush with Microban...

Page 20

New Five Year Warranty on Healthy Home Vacuum™
This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. If you need additional instruction regarding this warranty or have questions regarding what it may cover, please contact BISSELL Consumer Services by E-mail, telephone, or regular mail as described below.
Limited Five Year Warranty
Subject to the *EXCEPTIONS AND EXCLUSIONS identified below, upon receipt of the product BISSELL Homecare, Inc....
Start reading Bissell 5770p Manual

Related Manuals for Bissell 5770p Manual

All Bissell manuals