Page 41
6. Installation Guidelines PDA B C PD 16 9SW Image 6-5 Calculation of the projector distance (PD) Below table of the lenses (available at time of printing) LensesMetric formulas (meter)Inch formulas (inch) CineVERSUM™(1.2 - 1.44 : 1)WidePD = 1.2 x SWPD = 1.2 x SW Te l ePD = 1.44 x SWPD = 1.44 x SW CineVERSUM™(1.44 - 1.8 : 1)WidePD = 1.44 x SWPD = 1.44 x SW Te l ePD = 1.88 x SWPD = 1.88 x SW CineVERSUM™(1.6 - 2.24 : 1)WidePD = 1.6 x SWPD = 1.6 x SW Te l ePD = 2.24 x SWPD = 2.24 x SW CineVERSUM™(2.24 - 4 :...
Page 42
6. Installation Guidelines 6.1.2.4 Projector installation requirements Cine VERSUM 80: Installation requirements • Position the projector perpendicular to the screen and leveled to achieve an optimal image. An inclination of the projector is allowed but limited to 10° in one direction (. The latter generates image distortion (keystoned) which can be corrected using the projector’s menu system. • The projector lens should be centered horizontally in themiddle of the screen (Vertical shift of the lens...
Page 43
6. Installation Guidelines When the height of the projected image is adjusted, the image maybecome distorted (keystoned),depending on the relative posi- tions of the projector and the screen. How to adjust the keystone correction, see Keystone Correction, page 110. Optical Axis Projector Lens 16 9 Optical Axis Projector Lens 16 9 1 2 Image 6-8 Lens shift 1 Lens shift fixed screen 2 Lens shift fixed projector Cine VERSUM 120: using the provided Lens Controls The Cine VERSUM 120 is equipped with a zoom...
Page 44
6. Installation Guidelines 6.1.2.6 Ceiling Mount for Cine VERSUM 80 Cine VERSUM 120 View Ceiling Mount assembly R9841750 Image 6-10 Ceiling mount for Cine VERSUM 80 For more details about the ceiling mount Cine VERSUM 80, see the concerning installation manual. R9842330 Image 6-11 Ceiling mount for Cine VERSUM 120 For more details about the ceiling mount Cine VERSUM 120, see the concerning installation manual. Ceiling Mount Extension Supports for Cine VERSUM 80 and Cine VERSUM 120 Two extension supports...
Page 45
6. Installation Guidelines 6.2 Plasma Screen Installation Guidelines Overview • About Installation of the Unit • Installation using the Wall mount kit • Installation using the Table mount kit 6.2.1 About Installation of the Unit To avoid malfunction, overheating of this unit, and possible fire hazard, make sure that the vents on the main unit are not blocked when installing. Also hot air is expelled from the air vents, be careful of deterioration and dirt build up on rear surface wall, etc.. Please be...
Page 46
6. Installation Guidelines This side has to be fixed to the plasma backplane M8x20 (for fixing support plate to plasma backplane) Image 6-14 Wall mount assembly Image 6-15 Dimensions wall mount assembly 6.2.3 Installation using the Table mount kit How to install the Table mount kit 1. Assemble the table mount as illustrated in drawing below. (image 6-16) 2. Mount the table mount onto the rear of the Cine VERSUM 50, using the ’a’ holes (Installation using the Wall mount kit, page 41). 42 R5976468 CINE...
Page 47
6. Installation Guidelines Image 6-16 Table mount assembly R5976468 CINE VERSUM SYSTEM 0311200343
Page 49
7. Connections 7. CONNECTIONS Overview • Power Supply Connection • Connection for Preview and Communication • Digital Link to Display Modules • Connection to Video Equipment 7.1 Power Supply Connection 7.1.1 Supplied Power Cords The following power cords are added to the product In the package of each product, two power cords are added, one with a plug shape, reference standard ANSI C73.11, and one with a plug shape, reference CEE (7). Image 7-1 Power cord ANSI for Cine VERSUM 50, Cine VERSUM 80...
Page 50
7. Connections Image 7-5 Insertion of the power plug AC Power Specifications AC Power VoltageAuto Range 100 – 240V AC Power Current1A/50–60Hz Main FusesStandby Power Supply: T 2AH/250V Main Power Supply: F 4A L 250V Power Consumption Normal operation mode78 W Depending on input configuration Standby mode8W Economic standby mode4W For continued protection against risk of fire, all fuse replacements must be made using VDE and UL Listed or Recognized fuses with the same voltage and current rating. 7.1.3...