Page 442
FUNCTIONAL DESCRIPTION Memory Administration and Feature Code Modules, which includes Station Call Processing, are software tasks associated with memory.Each task controls the storage and movement of data and messages between elements in the system. l Administration Provides for administration of station and system features. This software also supports maintenance procedures related to error checking and diagnosing trouble. l Feature Code Modules Includes the software that receives and sends data to/from...
Page 443
FUNCTIONAL DESCRIPTION l Operating System (OS) Controls all message and data flow to/from memory, to the Arch Angel Driver Interface, to the microprocessors on the port circuit packs, and to the RS-232 driver interfaces. Messages destined for a particular task are queued until the associated task can receive them. When a task has completed a particular process, the next message is obtained from the message queue of the tasks. The OS provides an interval timer that is used to time tasks.Processes that...
Page 444
FUNCTIONAL DESCRIPTION 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. The OS checks a message directory to determine which task (i.e., software module) is to receive the message. A function of the OS referred to as the “transformer” determines it has a message for the Station Call Processing task and queues the message in RAM. The Station Call Processing task retrieves its message and interprets it as a call origination. The task determines whether there is an idle call appearance button (System Access...
Page 445
FUNCTIONAL DESCRIPTION 18. When either of the parties hangs up, the associated port circuit controller sends an up-link message to the Station Call Processing task. 19. Station Call Processing interprets the on-hook message as the end of the call. 20. The task then sends a down-link message to the port circuit pack controllers to disconnect the time slot connections and turn off the LEDs associated with the calls. 3-44
Page 446
HARDWARE DESCRIPTION System Cabinets (J58901A1 L4) Cabinet 1 (Control and Port Circuits) Cabinets 2 and 3 (Port Circuits) Cabinet Address Plug4-1 4-4 4-4 4-6 Circuit Packs Required Circuit Packs Optional Circuit Packs Station Port Circuit Packs Trunk Port Circuit Packs System Resource Circuit Packs Circuit Pack Compatibility Circuit Pack Features 4-7 4-8 4-9 4-9 4-11 4-12 4-13 4-13 Terminal Equipment Voice Terminals Single-Line Voice Terminals 500 Series 2500 Series 2526BMWG Voice Terminal 7101A Voice...
Page 447
7313H01A Voice Terminal (BIS-10) (PEC 3165-10B) 4-38 7314H01A Voice Terminal (BIS-22) (PEC 3166-22B) 4-40 7316H01A Voice Terminal (BIS-34) (PEC 3167-34B) 4-42 7317H01A Voice Terminal (BIS-34D) (PEC 3167-DSB) 4-44 10-Button MET Set (2991C/D05) 4-46 10-Button MET Set With Built-In Speakerphone (2993C04) 4-48 12-Button MET Set (7203M) 4-50...
Page 449
Figures Figure 4-1. Figure 4-2. Figure 4-3. Figure 4-4. Figure 4-5. Figure 4-6. Figure 4-7. Figure 4-8. Figure 4-9. Figure 4-10. Figure 4-11. Figure 4-12. Figure 4-13. Figure 4-14. Figure 4-15. Figure 4-16. Figure 4-17. Figure 4-18. Figure 4-19. Figure 4-20. Figure 4-21. Figure 4-22. Figure 4-23. Figure 4-24. Figure 4-25. Figure 4-26. Figure 4-27. Figure 4-28. Figure 4-29. Figure 4-30.System 25 Cabinets (J58901A)—3-Cabinet System 4-3 System Cabinet (J58901A)—Rear View...
Page 450
Figure 4-31.Out-of-Building 7300H Series Multiline Voice Terminal Connections - 4-72 Figure 4-32.MET Set Connections 4-73 Figure 4-33. Stand-Alone Remotely Powered Multiline Voice Terminal and ATL Cordless Telephone Connections 4-74 Figure 4-34.Typical ADU Connections— Supporting Data Terminal and Single- LineVoiceTerminal 4-75 Figure 4-35.Typical ADU Connections— Supporting Data Terminal...