SYSTEM HARDWARE
Physical Characteristics: The TDM bus is an 8-bit bus. The bus snakes
continuously between cabinets in a multicabinet system as shown in Figure
3-8. The total length is about 9 feet for a 3-cabinet system. The bus is
driven from any of the circuit packs in the cabinets. Similarly, a signal on the
bus can be received by any circuit pack.
Within a cabinet, the bus is printed on one side of the circuit pack carrier
backplane, and the other side is solid ground. Ribbon cables are used to...

Page 42

SYSTEM HARDWARE
TDMBUS
TERMINATOR
CARD
CABINET 3
ON/OFF
SWITCH
AC POWER
# 6 AWG
BUILDING
GROUND
WIRE TDM BUS
EXTENDERCABLE
CABINET 2
AC POWER
#6 AWG
GROUND
WIRE
CABINET
1
COUPLED
BONDING
CONDUCTOR
(CBC)
AC POWER
TO SINGLE
POINT GROUND
Figure 3-8. TDM Bus Diagram—3-Cabinet System
3-20 

Page 43

SYSTEM HARDWARE
Port Circuits
The following port circuit packs provide the link between trunks and external
equipment and the TDM bus:
l Ground Start Trunk (ZTN76)
l Loop Start Trunk (ZTN77)
l Tip Ring Line (ZTN78).
l ATL Line (ZTN79)
l Data Line (TN726)
l MET Line (TN735)
l Analog Line (TN742)
l DID Trunk (TN753)
l Tie Trunk (TN760B)
l Auxiliary Trunk (TN763)
l STARLAN Interface (ZTN84) (V2)
Figure 3-9 shows the equipment types that can be connected to the digital
switch by the Call Processor and port...

Page 44

SYSTEM HARDWARE
Figure 3-9.
Equipment Connected to System 25 By Call Processor and
Port Circuit Packs (Sheet 1 of 3)
3-22 

Page 45

SYSTEM HARDWARE
Figure 3-9.
Equipment Connected to System 25 By the Call Processor
and Port Circuit Packs (Sheet 2 of 3)
3-23 

Page 46

SYSTEM HARDWARE
LEGEND:ADU –
CAS -
CO -
CP -
DID -
DTU –
FX -
MET –
OPS -
SAT –
SMDR -
WATS -
ASYNCHRONOUS DATA UNIT
CALL ACCOUNTING SYSTEM
CENTRAL OFFICE
CIRCUIT PACK
DIRECT INWARD DIALINGDIGITAL TAPE UNIT
FOREIGN EXCHANGE
MULTIBUTTON ELECTRONIC TELEPHONE
OFF-PREMISES STATION
SYSTEM ADMINISTRATION TERMINAL
STATION MESSAGE DETAIL RECORDING
WIDE AREA TELECOMMUNICATIONS SERVICE
Figure 3-9.Equipment Connected to System 25 By the Call Processor
and Port Circuit Packs (Sheet 3 of 3)
3-24 

Page 47

SYSTEM HARDWARE
Eight port circuits are provided on most port circuit packs. The MET Line,
Tie Trunk, and Auxiliary Trunk CPs each contain four port circuits. The port
circuits provide an interface between terminals/trunks and the TDM bus. The
STARLAN Interface CP (V2) is unique. It provides one interface (port) to a
Network Extension Unit (NEU) and four connections to the TDM bus.
The number of port circuit packs required varies per customer requirements
and equipment configuration.
Each of the System...

Page 48

SYSTEM HARDWARE
Figure 3-10. Port Circuit Pack Common Circuitry
3-26 

Page 49

SYSTEM HARDWARE 

Page 50

SYSTEM HARDWARE
NPEs (Network Processing Element): Each port circuit pack contains one or
two NPEs. The Analog Line, ATL Line, Tip Ring Line, Data Line, Ground
Start, Loop Start, and DID Trunk circuit packs contain two NPEs. The MET
Line, Auxiliary Trunk, and Tie Trunk circuit packs contain one NPE.
The NPEs perform switching network functions for the port circuits. Under
control of the on-board microprocessor, an NPE can connect a port circuit to
any one of the TDM bus time slots. More specifically, it...
Start reading ATT System 25 Maintenance Manual

Related Manuals for ATT System 25 Maintenance Manual

All ATT manuals