ATT System 25 Administration Manual
Here you can view all the pages of manual ATT System 25 Administration Manual. The ATT manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 181
TABLE 16-9 MET Set Button Defaults 7 - SYS ACCESS 8 - SYS ACCESS 9 - REP DIAL 10 - REP DIAL 11 - LAST # DIALED Message† Drop† Conference† Transfer† Hold† † Cannot be changed. 16-18 Command Reference
Page 182
TABLE 16-10 PORT/PDC Administration, Data Terminals (Menu=1/2) ACTIONDESCRIPTIONDATA OPhysical port numberCSSPP Enter data type code[See Table 16-10] 2 Enter DDC[1-9999; 600-704] 3Restrict dial access to CO trunk pool† [1=Y/0=N] 4 Restrict dial access to all other trunk pools†[1=Y/0=N] 12DDC of station to hunt to next[PDC; 0 for none] 13Restrict this station from making outward[1=Y/0=N] calls? 14Assign toll restriction class?[1-5; 0 for none] 15Assign ARS Facility Restriction Level?[0-3; 3] 21 Enter...
Page 183
TABLE 16-10 PORT/PDC Administration, Data Terminals (Menu=1/2) (continued) ACTIONDESCRIPTIONDATA 70Allow keyboard dialing/Command Mode†[1=Y/0=N] 71Allow user configuration of data port[1=Y/0=N] parameters.† (The default is 0 for STARLAN CP.) 72Allow mismatch of user’s data module and [1=Y/0=N] data port baud rate† 73Allow characters dialed from keyboard to be[1=Y/0=N] echoed by the data port† 74 Enter your disconnect code†[1-2 short BREAKS/ 0-1 long BREAK] 75Allow call progress text messages to...
Page 184
TABLE 16-12 PORT Administration, Trunks (Menu=1) ACTIONDESCRIPTIONDATA OPhysical port numberCSSPP 1Enter trunk port type code[See Table 16-13] 2Enter trunk number[0001-9999; 0001-0104] 3Assign Class-of-Service code[(DID 1-4; 3) (All other— See Table 16-14; 8)] 4Assign pooled facility access code.[Facility access code; (100, 101, 102) 0 if trunk not in any group 5Allow dial access[1=Y/0=N] 6Assign the trunk to a DGC group[1-32; 0 for none] 7Make this a directed night service trunk[1=Y/0=N] 8Assign night...
Page 185
TABLE 16-13 Trunk Type Codes If the Trunk Type is: Code: Ground Start, CO 701† Ground Start, WATS, FX Ground Start, PBX/Centrex Loop Start, CO Loop Start, WATS, FX Loop Start, PBX/Centrex DID Immediate Dial DID Wink Start Auto-in/Auto-out Auto-in/Immediate Dial-out Immediate Dial-in/Auto-out Immediate Dial-in/Immediate Dial-out Wink Dial-in/Auto-out Wink Dial-in/Wink Dial-out Delay Dial-in/Auto-out Delay Dial-in/Delay Dial-out 702 705* 801† 802 805* 901 902† 1001 1002 1003 1004 1005 1006† 1007 1008 †...
Page 186
TABLE 16-14 Trunk Class of Service (for all trunks, except DID) TRUNK CLASS OF SERVICE (FOR ALL TRUNKS EXCEPT DID) COS CODE O 1 2 3 4 NIGHTOUTWARDINSHORT SERVICESIGNALINGONLYDISCONNECT TT TT l TTl TTll 5 6 7 8 9 10 11 12 13 14 15DP DPl DPl DPll lTT lTT l lTTl lTTll lDP lDP l lDPl lDPll TT = Touch Tone DP = Dial-Pulse November 1995Command Reference 16-23
Page 187
TABLE 16-15 Port Administration, Auxiliary Equipment (Menu=1) ACTIONDESCRIPTIONDATA ODisplay physical port number, in the form CSSPP 1Enter special feature port type code(see Table 16-16) 1Assign external alerts[253] 2Assign associated station number[PDC of associated station, 0 if night service alert] 1Assign paging Interface (associated with auxiliary[1301-1303] trunk circuit) 2Assign PDC for this zone[PDC (zone 1) PDC (zone 2) PDC (zone 3) 0 for none] 3Assign all-zone PDC[PDC for all-zone, 0 for...
Page 188
TABLE 16-15 Port Administration Auxiliary Equipment (Menu=1) (continued) ACTION DESCRIPTIONDATA 1 Assign pooled modem[1901] 1 Assign additional tone detector[2101] 1 Assign dial dictation[2201 (aux. trunk interface); 201 (station port interface)] 2 Assign dial dictation PDC[PDC] 1 Assign selector console[1601 or 1602] 21-27 Assign the hundreds group to this button. TABLE 16-16 Auxiliary Equipment Port Type Codes This table shows data values associated with Action=1 on Table 16-15. FEATURE TN742,...
Page 189
TABLE 16-17 Port Options PORTS, Station/Trunk/Special Port Circuit Board Options FOR QUALIFIED SYSTEMS TECHNICIANS ONLY† (See Table 16-18, “Applicable Options”) ACTIONDESCRIPTION DATA 32 Set CO disconnect time (in 20 msec increments)[0-2540 msec; 500] 33 Set end-to-end signaling tone timing (in 20 msec increments) FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 340] FOR ALL OTHER BOARDS:[0-2540 msec; 60] 34 Set end-to-end signaling pause timing in 20 msec increments) FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 100]...
Page 190
TABLE 16-18 Available Options See WARNING for Table 16-17. In this table, a bullet indicates that the default value for that action (shown in Table 16-17) is applicable for this circuit board. CIRCUIT BOARD ZTN76 ZTN77 TN753 TN760LS Trunk l ll ll ll l DID Trunk TN763 TN742 ZTN78 ZTN79 TN735 ZTN85 TN748 BOARDACTION TYPE32333435†363738 GS Trunkllll TIE Trunklllll AUX Trunkll T.T. Stationlglgll T.T. Stationlglg ATL Station MET Station Svc. Ckt. Tone Det. ZTN131 TN767 TN767 TN767 TN767 TN767Svc. Ckt. OPS...