Page 71
LED Cinema Display (27-inch) Take Apart — LCD Temp Sensor Cable 71 2010-11-18 First Steps Remove: • Glass Panel • LCD Panel Note: A new LCD panel includes a new temp sensor cable. Tools • ESD wrist strap LCD Temp Sensor Cable
Page 72
LED Cinema Display (27-inch) Take Apart — LCD Temp Sensor Cable 72 2010-11-18 Removal 1 Note cable routing and placement of tape securing cable to LCD panel. 2 Peel back mylar at top rear of LCD panel. 3 Pull cable straight out of connector. 4 Peel back foam gasket covering sensor at bottom rear of LCD panel. Replacement Note: Fully cover sensor with gasket to isolate from internal air temperature. 5 Remove cable from LCD panel.
Page 73
LED Cinema Display (27-inch) Take Apart — LCD Ground Cable 73 2010-11-18 First Steps Remove: • Glass Panel • LCD Panel Note: A new LCD panel does not include a new ground cable; it must be transferred from old LCD panel. Tools • ESD wrist strap • Phillips #0 screwdriver LCD Ground Cable
Page 74
LED Cinema Display (27-inch) Take Apart — LCD Ground Cable 74 2010-11-18 Removal 1 Remove Phillips #0 screw: (1) 922-9724 2 Remove cable from LCD panel.
Page 75
LED Cinema Display (27-inch) Take Apart — Camera 75 2010-11-18 First Steps Remove: • Glass Panel • LCD Panel Important: The camera assembly contains an ambient light sensor. When replacing camera, use the EEPROM Reset Tool to reset the ambient light sensor’s calibration factor. Tools • ESD wrist strap • Torx T10 screwdriver • Black stick Camera
Page 76
LED Cinema Display (27-inch) Take Apart — Camera 76 2010-11-18 Removal 1 Remove T10 screws: (2) 922-9723 2 Lift camera out of rear housing. 3 Disconnect cable from camera. Reassembly Note: Thermal paste is required between camera and rear housing. Use a black stick to remove thermal paste from old camera and reapply to new camera (areas circled). Note: A syringe of thermal paste is available as needed, Apple part# 922- 9625, good for 5 applications.
Page 77
LED Cinema Display (27-inch) Take Apart — Camera 77 2010-11-18 EEPROM Reset Tool After replacing the camera in an LED Cinema Display (27-inch), run the EEPROM Reset Tool to reset the Ambient Light Sensor (ALS) calibration factor. This tool should only be run when the camera has been replaced. 1. Download the EEPROM Reset Tool from Service Source, by navigating the Product Browser to “Displays” and then to “LED Cinema Display (27-inch).” 2. Launch the EEPROM Reset Tool on a host computer that is...
Page 78
LED Cinema Display (27-inch) Take Apart — Camera 78 2010-11-18 4. If the camera has been replaced, choose “Yes”. The Ambient Light Sensor (ALS) EEPROM calibration factor will be reset and the following message will appear: 5. Unplug the display’s power cord from AC outlet, wait at least 10 seconds, and then reconnect to AC power in order to cycle the unit. The window above should re-appear on the screen. 6. Select the “Compare EEPROM default” button. The response should be: 7. The reset process is...
Page 79
LED Cinema Display (27-inch) Take Apart — Camera Cable 79 2010-11-18 First Steps Remove: • Glass Panel • LCD Panel • Camera Removal 1 Note cable routing through black plastic guides in rear housing, and tape securing camera cable to rear housing. 2 Disconnect cable from camera and from logic board. Reassembly Note: For easier access to reconnect cables, unscrew and flip over logic board. Camera Cable
Page 80
LED Cinema Display (27-inch) Take Apart — Power Supply 80 2010-11-18 First Steps Remove: • Glass Panel • LCD Panel Warning: HIGH VOLTAGE: Use extreme caution when working around the power supply, which contains a high-voltage capacitor that may remain charged for several minutes even when unit is unplugged. Never touch leads on top side of power supply, especially those near warning sign. Tools • ESD wrist strap • Torx T10 screwdriver Power Supply