Home
>
Anetsberger Brothers
>
Fryer
>
Anetsberger Brothers Filtration System FFM80FFM150 Portable filters available in 80 lb or 150 lb shortening capacities User Manual
Anetsberger Brothers Filtration System FFM80FFM150 Portable filters available in 80 lb or 150 lb shortening capacities User Manual
Here you can view all the pages of manual Anetsberger Brothers Filtration System FFM80FFM150 Portable filters available in 80 lb or 150 lb shortening capacities User Manual. The Anetsberger Brothers manuals for Fryer are available online for free. You can easily download all the documents as PDF.
Page 1
URCUL Anets ~ Dependable Foodservice Equipment PO Box 501 Concord, NH 03302 Tel: 603-225-6684 Fax: 603-228-5231 Portable Filter Systems Models FFM-80 FFM-150 Installation, User Operation, & Maintenance Manual DANGER Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment....
Page 2
TABLE OF CONTENTS Shipping Container Inspection....................................................... 2 Code Requirements ...................................................................... 4 Filter Unit Preparation Instructions ................................................ 4 Filter Diagrams .............................................................................. 5 Filtering Instructions ...................................................................... 6 Oil Disposal...
Page 4
INSTALLATION INSTRUCTIONS FILTER ELECTRICAL SPECIFICATIONS Please make sure that your desired filter location has electrical supply factors that are suitable for this product line. Requirements are120 Volts, 60 Hz, 8 Amps, 1-phase, three wire connection, including an electrical ground. This unit is not fused. Protect circuit with proper sized fuses or circuit breaker line disconnect switch, circuit breaker, or plug and receptacle of power cord connection should be readily...
Page 5
FFM PORTABLE FIL TER Foldable handle Quick- connect coupling for filter screen assembly Filter screen assembly Filter envelope Knurled retaining nut FFM PORTABLE FIL TER COMPLETELY ASSEMBLED Quick- connect coupling Pump quick-connect coupling Filter envelope clip Knurled retaining nut Filter envelope L20-344 Rev 2 Completely Disassembled Pump quick-connect coupling Filter tank Cover Filter envelope cli p Hose...
Page 6
1. Before filtering the shortening in a fryer turn the thermostat knob to “OFF” or the Gas valve to “PILOT” to prevent the fryer from re-lighting during filtering. On some models the system automatically prevents the burners from lighting when the door of the fryer is open. 2. Roll filter under drain pipe extension on the fryer and slowly open drain valve handle, letting all the shortening drain into the filter tank. Leave this valve open. ! Never drain more than...
Page 7
6. On gas-operated thermostat models (such as Anets 14G, 14GS, MXEG, 18EG, 20EG) the thermostat knob can now be turned back to the desired temperature. CAUTION: On these models the thermostat must be set to “OFF” or the Gas Valve to “PILOT” before filtering or the burners MAY come back on if the doors are closed during filtering. 7. On electric-operated thermostat models (such as Anets MX-14E, MX-14EX, MX-14AA, 18E, 18AA, 20E, 14EL-14 and 14EL-17) the power switch on the control panel must be...
Page 8
REPLACING THE FIL TER P APER If the filter paper becomes torn, or if the time to filter the oil from one unit becomes excessive, it is time to replace the Filter Envelope. WARNING Only use filter paper envelopes from Anets that have been specifically designed for this filter system . Using the wrong type of filter paper can cause damage to the pump system, and will void the Warranty 1. Unplug the cord from the receptacle. 2. Disconnect the line from the pump to the filter screen....
Page 9
FILTER SY STEM TROUBLESHOOTING GUIDE SOLUTION 1. Make sure the power cord is plugged into the proper 120 Volt receptacle. 2. Turn the switch on the front of the filter to “ON”. 3. If the pump still hasn’t started, depress the thermal overload button on the bottom of the motor. If the motor is hot to the touch, wait at least 15 minutes before trying this. 4. If the pump starts and stops again in a short time, or if it hums but does not pump, there is a restriction somewhere in the filter...