Page 1

1                        L20-349 R3 
 
        Anets Inc. 
Mailing Address: P.O. Box 501, Concord,NH  03302-0501 USA  Telephone:  603-225-6684 
                     Shipping Address: 10 Ferry Street, Concord, NH  03301 USA 
       www.anets.com 
 
 
FRYER 
Model 
SLG40 
 
Installation, 
User Operation, 
&
 
Maintenance 
Manual 
SLG40 shown on standard 6” legs 
 
! 
Improper installation, adjustment, alteration, service, or maintenance can 
cause property damage, injury or death.  Read the installation,...

Page 2

2                        L20-349 R3 
 
 
 
 
 
 
 
CONTENTS 
Shipping Container Inspection ....................................................... 3 
Fryer Gas Supply Specifications .................................................... 3 
Fryer Electrical Specifications  ....................................................... 3 
Figure 1 - Fryer Wiring Diagram  ............................................ 3 
Code Requirements  ...................................................................... 4...

Page 3

3                        L20-349 R3 
 
SHIPPING CONTAINER INSPECTION 
1.Carefully examine the shipping carton for external 
damage.  When damage is noted, notify the delivery 
carrier immediately. Save all packing materials for 
damage claim examination. 
2. If no external damage is noted, remove the shipping 
carton from the fryer and examine the fryer  carefully for 
damage.  Place the fryer in a safe location, if damage is 
noted, so that the freight damage claims adjuster can 
examine the fryer. 
3....

Page 4

4                        L20-349 R3 
 
CODE REQUIREMENTS 
IMPORTANT:  Read the Code Requirements and ALL 
installation instructions carefully, before starting the 
installation. Contact the fac- tory (1-603-225-6684) if any 
problems or questions arise. 
 
The fryer installation must conform with local codes, or 
in the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.1 (latest edition); the Natural Gas 
Installation Code, CAN/CGA-B149.1 (latest edition);  or 
the Propane Gas...

Page 5

5                        L20-349 R3 
 
INSTALLATION 
Install the fryer in accordance with the preceding Code 
Requirements, as well as the following Installation 
Requirements. 
 
1. DO NOT install this fryer in a mobile home, 
trailer, or recreational vehicle. 
 
2. Install this fryer in a location that allows it to be 
moved away from other adjacent appliances 
for cleaning and maintenance. 
 
NOTE: If the fryer is installed among 
a row of appliances (“banked”), with 
its only convenient movement...

Page 6

6                        L20-349 R3 
 
LEG INSTALLATION INSTRUCTIONS 
1. Position the fryer on its side on a clean surface. 
2.  Attach each leg with four bolts, washers and nuts 
(provided). 
3. Tighten securely 
LEG LEVELING 
INSTRUCTIONS 
 
1.  Move the fryer to its desired location. 
2.  Turn the screw-type leg adjustment ends as 
necessary to level the fryer, until NO tipping, 
rocking, or wobbling is evident. 
3.  P e r f o r m  t h e  “Fryer Restraining Device 
Installation Instructions.”...

Page 7

7                        L20-349 R3 
 
GAS CONNECTION INSTRUCTIONS 
Installing your ANETS Fryer requires the fol- lowing 
procedure, after its legs or casters are pro-
perly attached and  it is in its desired location. 
 
1.  Ensure that the gas safety valve control knob 
in the fryer has its OFF position next to the 
valvemark. 
 
2.  Ensure that the gas supply inlet line valve is 
closed (crosswise to the line direction). 
 
3.  Ensure that the fryer’s thermostat is set to 
OFF. 
4. Connect the ½” gas...

Page 8

8                        L20-349 R3 
 
FRYER OPERATING INSTRUCTIONS 
Normal operation of an ANETS Fryer requires that the kettle is filled with liquid shortening to above the lower indent 
level marked on the rear of the kettle, before lighting the fryer’s main burners. 
 
CAUTION: Shortening MUST be in liquid form to avoid scorching or discoloration and possible damage to the kettle. 
Damage caused by melting solid shortening will 
NOT be covered by the warranty. 
 
FRYER PREPARATION FOR USE 
“BOIL OUT”...

Page 9

9                        L20-349 R3 
 
FRYER OPERATING 
LIGHTING PROCEDURE 
 
N
OTE: The gas line of a new fryer installation may 
contain a considerable amount of air which will hinder 
immediate lighting.  You may have to press in the control 
knob as long as several minutes before the pilot flame 
burns steadily. 
 
1.  Open the front door and ensure that the fryer’s 
thermostat knob is set to OFF. 
2.  Open the gas supply line inlet valve to the fryer by 
aligning the gas valve handle with the gas...

Page 10

10                        L20-349 R3 
 
FRYER OPERATING INSTRUCTIONS (Continued) 
 
DAILY CLEANING PROCEDURE 
 
NOTE: Cleaning is recommended at the end of a 
workday to prepare the fryer for proper operation the next 
time it is to be used.
 
 
 
 
 
 
 
 
 
 
 
 
1.  Open the front door of the fryer.  Attach the drain 
extension to the drain ball valve. 
2. Perform the Shutdown Procedure. Ensure that the 
gas supply line inlet valve is closed (handle cross-wise to 
pipe line) and the pilot flame is...