11 #L010128June 2002 8 Lead Motors Series Connection: When configuring the motor windings in series, use the per phase (or unipolar) current rating to determine the current setting potentiometer value. Parallel Connection: When configuring the motor windings in parallel, multiply the per phase (or unipolar) current rating by 2.0 to determine the current setting potentiometer value. Note: After the current has been determined, according to the motor connections above, use the potenti- ometer setting table...
Page 12
12 #L010128June 2002 Functions Soft Limit Switches: These switches cause the pulse generator to ramp down to the base speed before encountering a hard limit switch. Hard Limit Switches: When a hard limit switch is encountered, the pulses will stop. Hard limits are intended as an emergency stop for your system. Profile Inputs: These inputs are used to select the specified speed profile. These inputs are used in conjuction with the Run input. If no profile inputs are selected then profile 1 will be used....
Page 13
13 #L010128June 2002 Installation Software The SMPG10WIN is supplied on a CD, containing the setup program and the SMPG10WIN software SMPG10WIN is compatible with all versions of Windows including Windows 2000 and Windows XP Windows 3.x Installation 1) Insert the CD into the drive 2) From the Program Manager select File | Run 3) Enter D:\setup and click OK - use the appropriate drive letter (i.e. D or E) Windows 95/98/NT/ME/2000/XP Installation Option 1 1) Insert the CD into the drive 2)...
Page 14
14 #L010128June 2002 “The Unit is Connected” / “The Unit is NOT Connected” On the right of the Toolbar, the user will find the communication status of the pulse generator. If commu- nications is not established, please refer to the troubleshooting section. File Menu Setup Menu Ext ier a w t f o s N I W 0 1 G P M S e h t t i x E Ct c e n n o. r e l l o r t n o c e h t h t i w s n o i t a c i n u m m o c h s i l b a t s E n o i t a c i n u m m o CS. . . s g n i t t e) 4 r o 3 , 2 , 1 s t r o P ( n o i t c...
Page 15
15 #L010128June 2002 Program Window e l i f o r P d e e p S. 4 - 1 s e l i f o r p d e e p s t c e l e S d n e S l e c e D / l e c c A) t s e w o l s = 5 5 2 , t s e t s a f = 1 ( . r o t a r e n e g e s l u p e h t o t r e t e m a r a p n o i t a r e l e c e d & n o i t a r e l e c c a d n e S e s a B d n e S d e e p S) c e s / p e t s ( . r o t a r e n e g e s l u p e h t o t r e t e m a r a p d e e p s e s a b d n e S d e e p S x a M d n e S) c e s / p e t s ( . r o t a r e n e g e s l u p e h t o t r...
Page 16
16 #L010128June 2002 Direct mode is used to directly control the motion for real time movements through serial communication. The pulse generator has 14 commands which are easy to remember for direct movement of a step motor. COM Port Settings Baud Rate:9600 Parity:None Data Bits:8 Stop Bits:1 Flow Control:Xon/Xoff Unit Selection In order to select a unit the @ command followed by 0 (address of the unit) must be sent. NOTE: There should be no spaces between the @ and the 0. How to select the unit: @0...
Page 17
17 #L010128June 2002 A - Acceleration/Deceleration Format: A#_[value] - where # is the speed profile number 1 thru 4 Sample: A1_255 Accel of profile 1 equals 255 Description: This command sets the acceleration profile which can be an integer value be- tween 1 and 255. The lower the value the faster the pulse acceleration, so a 1 is the fastest profile and 255 is the slowest. These values are saved in the EEProm for standalone use. Range: 1 - 255 B - Base Speed Format: B#_[value] - where # is the speed...
Page 18
18 #L010128June 2002 G - Go Slew (Run) Format : G# - where # is the speed profile number 1 thru 4 Description: This command will send clocks out to the pulse generator. The only command that can stop the clocks is H (stop motion). The S(soft limit) command will make the pulses go from max speed to base speed. Motion can also be stopped by using the limit switch inputs. The ramp profile is specified by the B (base speed), M (max speed), and A (acceleration/deceleration) commands. H - Hard Limit or Stop...
Page 19
19 #L010128June 2002 V - Verify Description: This command can be used with most commands to verify the register contents. This is a read only command. Valid Commands are: A, B, C, D, M, R, and +. Format: V[command] This format is good for C, D, R, and +. C - If a 1 is sent back then the driver is in reduced current mode. If a 0 is sent back then the driver is not in reduced current mode. D - If a 1 is sent back then the pulse generator will ramp down to stop when the Run/ Stop input is released. If a 0...
Page 20
20 #L010128June 2002 Troubleshooting Problem: Can not establish communications with the pulse generator. Possible Solutions: 1) Make sure the pulse generator has power. Is the Green LED on. 2) Check RS232 connections. 3) Check for loose cable connection either on the pulse generator or COM Port. 4) Was the software installed successfully? 5) Go to Setup | Communication Settings and verify COM port and baud rate settings. 6) Click on Connect icon to communicate with the pulse generator. 9) If problems...