Anaheim Stepper MBC25P11 Users Guide
Here you can view all the pages of manual Anaheim Stepper MBC25P11 Users Guide. The Anaheim manuals for Stepper are available online for free. You can easily download all the documents as PDF.
Page 1
1 #L010128June 2002 MBC25P11 Programmable Pulse Generator/Driver User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION
Page 2
2 #L010128June 2002 Table of Contents Features ................................................................................................................................................... 3 Introduction .............................................................................................................................................. 3 Motion Profiles and Running the Pulse Generator ................................................................................... 3 Operation with Ramp...
Page 3
3 #L010128June 2002 Introduction The MBC25P11 is an economical single axis step motor driver integrated with a programmable pulse generator. The MBC25P11 microstep driver/pulse generator has an output current capability of 0.5A minimum to 2.5A maximum (peak rating). The MBC25P11 driver operates with a DC voltage of 12VDC to 35VDC. The MBC25P11’s internal PG (pulse generator) has four different programmable motion profiles. The MBC25P11 also has directional soft and hard limit switch inputs, a busy output...
Page 4
4 #L010128June 2002 AB C Max Speed Base Speed Off Time Speed Operation with Ramp Down Option A) Run is activated; Starts at base speed and immediately ramps up to max speed. B) Run is still active; Max speed is reached (keeps running at max speed). C) Run is inactivated; Motor ramps down. D) Pulses automatically stop when base speed is reached. AB CD Max Speed Base Speed Off Time Speed Operation without Ramp Down Option A) Run is activated; Starts at base speed and immediately ramps up to max speed. B)...
Page 5
5 #L010128June 2002 LEDs When powered and operated properly, the status LED will be green. When an error occurs, the LED will change to RED and an error code will be generated in the error code register. To read and clear the error with the software, click on the “Verify Parameters” button located in the “Motion Tab”. To read and clear the error while in “Direct Mode” use the “!” command. Once the error has been read and cleared, the LED will return to green and the error code register will be cleared....
Page 6
6 #L010128June 2002 Hard Limits: These two inputs are active low and are controlled by the direction of the pulse generator. When the pulse generator is running in the positive direction only hard+ will work. When the pulse generator is running in the negative direction then only hard- will work. When pulled low the pulse generator will stop all pulses to the motor. To reverse off of a Hard Limit, release the Run input, change directions, and activate the Run input again to move in the opposite...
Page 7
7 #L010128June 2002 s t n e m e r i u q e R e g a t l o VCD V 5 3 - 2 1 ) 8 n i P , 2 P ( t u p n I n u Rp o t Sev i t c a n I n u Rev i t c A ) 4 n i P , 2 P ( t u p n I n o i t c e r i DW Cev i t c a n I W W Cev i t c A ) 3 n i P , 2 P ( t u p n I f f O / n On Oev i t c a n I f f Oev i t c A ) 2 n i P , 3 P ( t u p t u O y s u Bf f O d n a t S C D V 0 4 , k n i S A m 5 7 , t u p t u O e p y t n i a r D n e p O ) 1 n i P , 3 P ( t u p t u O k c o l Cf f O d n a t S C D V 0 4 , k n i S A m 5 7 , t u p t...
Page 8
8 #L010128June 2002 Wiring Diagrams Two Motors One Motor Dimensions and Jumper/Potentiometer Locations
Page 9
9 #L010128June 2002 Setting the Output Current The output current on the MBC25P11 is set by the on-board potentiometer R29 (Refer to Dimensions/ Jumper and Potentiometer Locations). This current adjust potentiometer determines the per phase peak output current of the driver. This relationship between the output current and the potentiometer setting is as follows: s g n i t t e S r e t e m o i t n e t o P t n e r r u C k a e Pg n i t t e S r e t e m o i t n e t o P A 5 . 0%0 A 7 . 0%0 1 A 9 . 0%0 2 A 1 ....
Page 10
10 #L010128June 2002 Step Motor Configurations Step motors can be configured as 4, 6, or 8 leads. Each configuration requires different currents. Refer to the lead configurations and the procedures to determine their output current. WARNING! Step motors will run hot even when configured correctly. Damage may occur to the motor if a higher than specified current is used. Most specified motor currents are maximum values. Care should be taken to not exceed these ratings. Determining Output Current The...