#L0101477 1 June 2008 DPF72452XCE INDEXER DRIVER PACK User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION
Page 2
#L0101477 2 June 2008 COPYRIGHT © 2008 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. DISCLAIMER Though every effort has been made to supply complete and accurate...
Page 3
#L0101477 3 June 2008 TABLE OF CONTENTS INTRODUCTION.................................................................................................................................... 4 DESCRIPTION and FUNCTION............................................................................................................ 5 MANUAL PRESET INDEXER ....................................................................................................... 5 BLD72 BILEVEL DRIVE...
Page 4
#L0101477 4 June 2008 INTRODUCTION The DPF72452XCE Driver Pack contains two Bilevel Step Motor Drivers (BLD72), a Manual Preset Indexer board, a Transformer, and a cooling fan. Figure 1 shows the general configuration and layout of the DPF72452XCE Driver Pack. The Thumbwheel Switch is used to set the index (number of steps or move distance) and the Manual switches and/or PLC are used to initiate indexing, homing or jogging. The Manual Preset Indexer is ideal for applications which are repetitive...
Page 5
#L0101477 5 June 2008 DESCRIPTION AND FUNCTION MANUAL PRESET INDEXER BOARD The Manual Preset Indexer board utilizes the PI45 Preset Indexer integrated circuit (I.C.). Functions available are Home, Hard and Soft Limit inputs, two Homing modes, Jog/Run, Fast Jog and switch selectable Base Speed, Maximum Speed, Acceleration/Deceleration. This board includes the necessary buffering and other circuitry for the PI45 chip that makes indexing easy. The board can be operated manually or with a Programmable...
Page 6
#L0101477 6 June 2008 6 +HOME LIMITSame as -HOME LIMIT except in CW direction. 7 -JOG/RUN A low level on this line causes the step motor to take one step in the CCW direction. Normally, the JOG/RUN inputs are manipulated by external pushbutton switches. A single depression of the switch causes a “jog” operation, while holding the switch down for 0.5 seconds causes a “slow run” condition. This command may be used with FAST to perform a fast run at the base speed rate. 8 +JOG/RUN Same as -JOG/RUN...
Page 7
#L0101477 7 June 2008 place to provide TTL levels (see section on Jumpers). 17 CLOCKThis output is an open collector output, 15 microseconds wide (minimum) that is the clock input for the motor driver. It is buffered to assure adequate drive for an LS-TTL input. This signal is internally connected to the driver. 18 0VDC Ground (0Vdc). 19 DIRECTIONClockwise (CW) motion causes this output to be active high i.e. logic “1”. Counterclockwise motion causes this output to be active low i.e. logic “0”....
Page 8
#L0101477 8 June 2008 K1 will energize immediately after completion of an index cycle and remain energized for approximately an amount of time set by the “COMPLETE PULSE WIDTH” POT. K2 will be energized throughout an index cycle MANUAL PRESET INDEXER TERMINAL (P2) DESCRIPTION PIN FUNCTIONDESCRIPTION 1 +5VDC +5VDC Regulated Voltage Supply Output 2 +12VDC Unreg +12VDC Unregulated Voltage Supply Output 3 0VDC Ground (0Vdc). 4 0VDC Ground (0Vdc). 5 9 - 12VAC IN 9 - 12VAC Voltage Supply Input for...
Page 9
#L0101477 9 June 2008 FAULT PROTECTION There are three types of fault detection. When a fault is detected, the driver turns off the motor current and the red Fault LED indicates which type of fault occurred. See the Troubleshooting section for more information. 1kn i l B w o l S - D E Lel b a c r o r o t o m e h t n i e r i w d e t r o h s 2kn i l B t s a F - D E Lel b a c r o r o t o m e h t n i e r i w n e p o 3yd a e t S n O - D E L)V 0 o t d e t r o h s e g a t l o v ( t l u a f d n u o r g If...
Page 10
#L0101477 10 June 2008 MOTOR/DRIVER CONNECTIONS Figure 3 shows the proper connection of the step motor. The CLOCK (pin 6) and DIRECTION (pin 5) inputs on the driver terminal block are internally connected to the CLOCK and DIRECTION outputs of the indexer (nothing should be connected to these inputs). # n i Pno i t p i r c s e D 11 e s a h P 23 e s a h P 33 & 1 e s a h P n o m m o C 4tu p n I t l u a F t e s e R 5)d e t c e n n o c y l l a n r e t n i ( n o i t c e r i D 6)d e t c e n n o c y l l a...