31 #L010119May 2002
N - Number of Steps
Format: N [value]
Description: This command sets the number of clocks for the controller to send out following a G
command.
Range: 0 - 8388607
G - Go Number of Steps
Format: G
Description: This command is used to send a set number of clocks out of the controller. An N
or P command must be entered before the G command.
S - Go Slew
Format : S
Description: This command will send clocks out to the controller. The only commands that can
stop the clocks are; . (stop...

Page 32

32 #L010119May 2002
H - Home
Format: H [binary]
Description: This command sends clocks out of the controller until the home limit or the soft limit
is active. There are two types of homing available.
Home Types: H0: In type 0 homing, the controller will send clocks until a soft limit is reached,
then ramp down to base speed. Clocks will continue until a home or hard
limit is reached.
H1: In type 1 homing, the unit will move until a home limit is reached, then
change directions, ramp down to base speed...

Page 33

33 #L010119May 2002
I - Read Inputs
Format: I
Description: This command returns the binary value of the inputs to the PC. Since the inputs
are pulled up internally, they will return a high when they are pulled low. For
example, if all inputs are active (grounded), the command will return a 15. If all
inputs are inactive (open), the command will return a 0. Input 1 is the LSB, input
2 is the second bit, input 3 is the third bit, and input 4 is the MSB. O - Set Outputs
Format: O [value]
Description: This...

Page 34

34 #L010119May 2002
Section 5: Troubleshooting
Problem:
Can not establish communications with the controller.
Possible Solutions:
1) Make sure the controller has power. Is the green LED on?
2) Check RS485 connections.
3) Check for loose cable connection either on the controller or COM Port.
4) Was the software installed successfully?
5) Go to 
Setup | Communication Settings and verify COM port and baud rate settings.
6) Physically verify that the axis address matches with the controller unit selected...

Page 35

35 #L010119May 2002
Problem:
The Controller has a fault condition.
Possible Solutions:
1) Verify your program for improper syntax that may cause an error code.
2) Physically press the reset button on the controller to clear an error.
3) Another way to clear an error is by using either the SMC50WIN software or the direct mode
    command instructions set.
4) The SMC50WIN can clear an error in the motion tab section by clicking on the verify param-
    eters button.
5) The direct mode commands can clear an...

Page 36

36 #L010119May 2002
Section 6: Tutorial
Sample Program 1:
Sample 1 illustrates a typical application where a system moves to a specific position required. The
sample program shows how to use the motion and goto instruction commands.
0 4000 8000
Start
Initiate Values
Move 4000 Steps
Repeat Last Move
Move to Position 0
Quit  

Page 37

37 #L010119May 2002
Sample Program 2:
Sample program 2 illustrates a typical application where a system is first sent home to a datum or 0
position. This sample program shows how a motor will move to 3 different positions utilizing some of the
motion commands and loop routine.
0 Position
(Home Position)2” 4”6”
1st
Position2nd
Position3rd
Position
Labeler Dryer Capper  

Page 38

38 #L010119May 2002
Start
Initialize Parameters
Move to 1st Position (Labeler)
Move to 2nd Position (Dryer)
Move to 3rd Position (Capper)
Quit
Delay 1 Sec
Loop 3 Times
Home to Position 0 

Page 39

39 #L010119May 2002
Appendix 1: ASCII Table for Direct Mode
l o b m y S I I C S Ae u l a V x e Hl o b m y S I I C S Ae u l a V x e H
n r u t e R e g a i r r a CD0H84
003I94
113JA4
2230 L03 C 4
333S L35 C 4
443MD4
553NE4
663OF4
773S35
883V65
993!12
A14$42
B24+B2
F64-D2
G74.E2 

Page 40

40 #L010119May 2002
Copyright
Copyright 2001 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced,
transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by
any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior
written permission of Anaheim Automation, 910 East Orangefair Lane, CA, 92801. The only exception to
this would be use of the program examples in this manual....
Start reading Anaheim Stepper DPC40511 Users Guide

Related Manuals for Anaheim Stepper DPC40511 Users Guide

All Anaheim manuals