ACP-MxI Series AC Induction Motor User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION December 2012L010583
Page 2
General Description The ACP-MxI Series are fractional horsepower induction motors. ACP-MxI series provide users that need a simple solution. The ACP-MxI offers different sizes to accommodate your needs. These AC Induction motors can be customized to have a clutch and/or brake. ACP-MxI series operate at 120 or 220VAC, so there is no need for a transformer, just hook up and go! ACP-MxI series AC Induction motors can also be mated with other accessories, another reason to choose Anaheim Automation...
Page 3
Wiring Diagram Part NumberuFVoltage ACP-M-2IK6A-C 0.8450 ACP-M-31K15A-C 1450 ACP-M-4IK25A-C 1.5450 ACP-M-5IK40A-C 2450 ACP-M-5IK60A-CF 4450 ACP-M-5IK90A-CF 5450 ACP-M-5IK120A-CF 7450 ACP-M-5IK150A-CF 8450Part Number uFVoltage ACP-M-2IK6A-A 2.5250 ACP-M-3IK15A-A 4250 ACP-M-4IK25A-A 6250 ACP-M-5IK40A-A 8250 ACP-M-5IK60A-AF 16250 ACP-M-5IK90A-AF 20250 ACP-M-5IK120A-AF 25250 ACP-M-5IK150A-AF 36250 Power Supply Requirements It is recommended that the ACP-MxI Series be powered by 120 VAC for the ACP-M-xIxxx-Ax...
Page 4
Part NumberPolesNo Load Speed (RPM) Rated Load Speed (RPM) Starting Current (A) Rated Current (A) Starting Torque(oz-in) Rated Torque (oz-in) Maximum Torque(oz-in) ACP-M-2IK6A-A 41800 1550 0.41 0.25 5.77.2 14.4 ACP-M-3IK15A-A 41800 1600 0.59 0.34 12.512.5 25 ACP-M-4IK25A-A 41800 1500 0.91 0.49 19.4 2550 ACP-M-5IK40A-A 41800 1575 1.50.74 33.337.5 75 ACP-M-5IK60A-AF 41800 1550 2.21.06 62.552.7 105.4 ACP-M-5IK90A-AF 41800 1625 3.11.7 6673.6 147.2 ACP-M-5IK120A-AF 41800 1610 2.85 1.65 107101 202...
Page 5
Dimensions Figure 4: Dimensions for ACP-M-2IK6A-(A)(C)V Figure 5: Dimensions for ACP-M-3IK15A-(A)(C)V Figure 6: Dimensions for ACP-M-4IK25A-(A)(C)V December 2012L010583
Page 6
Dimensions Figure 7: Dimensions for ACP-M-5IK40A-(A)(C)V Figure 8: Dimensions for ACP-M-5IK60A-(A)(C)V Figure 9: Dimensions for ACP-M-5IK90A-(A)(C)V, ACP-M-5IK120A-(A)(C)V, ACP-M-5IK150A-(A)(C)V December 2012L010583
Page 7
AC Induction Motor FAQ What happens if I remove the internal brake mechanism of an AC induction reversible motor? Can I then use it as a regular AC induction motor? An AC reversible motor is an AC induction motor, but is made different. An AC reversible motor has it coils wound specifically for the application of a quick reversal movement. The AC reversible motor has it primary and secondary coils altered. Having a different ratio between the primary and secondary coils, its starting torque...
Page 8
ANAHEIM AUTOMATION COPYRIGHT Copyright 2012 by Anaheim Automation. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated in\ to any language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Anaheim Automation, 910 E. Orangefair Lane, Anaheim, CA 92801. DISCLAIMER Though every effort has been made to supply complete and...