31 Section 5: Direct Talk Mode Direct mode is used to directly control motion for real time movements through serial communication. The DPN10601 controller has 40 commands, which are easy to remember for direct movement of a step motor. COM Port Settings Baud Rate: 38400 Data Bits: 8 Parity: None Stop Bits: 1 Flow Control: Xon/Xoff Unit Selection In order to select a unit, the @ command followed by the address of the unit must be sent. NOTE: There should be no spaces between the @ and address select. How to select a unit: @0 (Unit 0 is selected) @1 (Unit 1 is selected) @29 (Unit 29 is selected) How to get a response from a unit: @0$ (Carriage Return) After the $ command, the DPN10601 will return a SMC60 + the current revision number . Note: In direct talk mode each command is followed by a carriage return. The unit communicates in half duplex mode, therefore proper setup of hyper terminal is necessary to view characters, if characters are to be echoed back to the screen. Instructions All instructions require that no spaces be sent between the command and the parameter followed by a carriage return. @0 not @ 0 correct: @0(carriage return) incorrect: @ 0 (carriage return) Command Summary: A - Acceleration/Deceleration B - Base speed C - Steps between outputs D - 1st output on the fly position EA - Encoder autocorrect enabled ED - Encoder delay EM - Encoder motor ratio ER - Encoder retries ET - Encoder reset EW - Encoder window G - Go number of steps H - Home I - Read inputs J- Fast jog speed M - Max speed N - Number of steps O - Set outputs P - Absolute position S - Go slew T - Motor current enabled V - Verify Z - Position ! - Error codes register $ - Version number % - Verify axis number ‘ - Index on the fly enabled ( - Output on the fly enabled + - Clockwise direction , - Stop soft - - Counterclockwise direction . - Stop hard / - Thumbwheel enabled : - Analog position enabled ; - Analog speed enabled [ - Analog speed lower limit ] - Analog speed upper limit ^ - Number of outputs { - Analog position lower limit } - Analog position upper limit ~ - Set address of DPN10601
32 A - Acceleration/Deceleration Format: A[value] Description: This command sets the acceleration profile which is an integer value between 100 and 9,999,999. The higher the value, the faster the motor acceleration. Range: 100 - 9,999,999 B - Base speed Format: B[value] Description: This command sets the base (start) speed for motion. This value must be set before motion begins and be less then the maximum speed and fast jog speed. Range: 1 - 5000 C - Number of steps between outputs during output on the fly Format: C[value] Description: Range: 0 - 65535 D - 1st Output on the fly position Format: D[value] Description: This command sets the position at which output 1 will turn on during an output on the fly move. This command is used in conjunction with the output on the fly enabled “(“ command. Range: 0 - 65535 EA - Encoder autocorrect enabled Format: EA[0 or 1] Description: This command sets the number of steps between when output 1 turns on during an output on the fly move. If only one output turn on is needed, set this value to 0. This command is used in conjunction with the output on the fly enabled “(“ command. This command will either enable or disable the encoder autocorrect function. To enable the function use a 1, to disable the function use a 0. When this function is enabled, the relative register is used to calculate the encoder position, therefore before the next move is made, the relative register needs to be set. This com- mand is used in conjunction with the encoder delay “ED”, encoder ratio “EM”, encoder retries “ER” and encoder window “EW” commands.
33 ED - Encoder delay Format: ED[value] Description: Range: 0 - 65535 EM - Encoder motor ratio Format: EM[value] Description: Range: 1 - 255 ER -Encoder retries Format: ER[value] Description: Range: 0 - 255 ET - Encoder reset Format: ET Description: This command will reset the internal encoder count register to 0. EW -Encoder window Format: EW[value] Description: Range: 0 - 255 This command sets the wait time a specified number of milliseconds after a rela- tive index or absolute move is finished, before reading the encoder. This is used to remove the ringing that might be associated with the mechanics of the system. This command is used in conjunction with the encoder autocorrect “EA” command. This represents the ratio for the number of encoder pulses to one motor step. An example is for a 1000 line quadrature encoder and a 400 step/revolution motor, the motor ratio is (1000 * 4) / 400 = 10. This command is used in conjunction with the encoder autocorrect EA command. This is the number of times the DPN10601 controller will try to autocorrect the motor before erroring. This command is used in conjunction with the encoder autocorrect EA command. When the autocorrect errors, Output 8 will be triggered. This is the allowable error in encoder pulses (either plus or minus) from the desired position that is allowed before the motor autocorrects. This command is used in conjunction with the encoder autocorrect EA command.
34 G - Go number of steps Format: G Description: This command is used to send a set number of clocks out of the DPN10601 controller. An N or P command must be entered before the G command. The ramp profile is specified by the B (base speed), M (max speed), and A (acceleration/deceleration) commands. H - Home Format: H[0 or 1] Description: Home Types: I - Read inputs Format 1: IR Description: Format 2: I[input] Description: This command returns the value of the selected input to the PC. If the input is open or high it will return a 1. If the input is grounded or low it will return a 0. Ranged: 0 - 6 J - Fast jog speed Format: J[value] Description: This command sets the fast jog speed. This value must be set before motion begins and be greater than the base speed. Range: 1 - 50000 H1: In type 1 homing, the DPN10601 will send clocks until a home limit is reached, ramp down to base speed, change directions and run at base speed unit the release of the home limit input. The ramp profile is specified by the B (base speed), M (max speed), and A (acceleration/deceleration) commands. H0: In type 0 homing, the DPN10601 will send clocks until a soft limit is reached, then ramp down to base speed. Clocks will continue at base speed until a home limit is reached. The ramp profile is specified by the B (base speed), M (max speed), This command returns the binary value of the inputs to the PC. Since the inputs are pulled up internally (except input 1), they will return a high when they are open. For example; if all inputs are active (grounded), the command will return a 0. If all inputs are inactive (open), the command will return a 63. Input 1 is the LSB
35 M - Max speed and analog speed Format 1: M[value] Description: This command sets the maximum (running) speed for motion. This value must be set before motion begins, and be greater than the base speed. Range: 1 - 50000 Format 2: M Description: N - Number of steps Format 1: N[value] Description: Range: 0 - 8388607 Format 2: N Description: O - Set outputs Format 1: OR[value] Description: This command sets the output register according to the binary value entered. Output 1 is the LSB and output 8 is the MSB. Range: 0 - 255 Format 2: O[output]=[0 or 1] Description: This command sets the selected output either on or off. A 1 will turn the output on (0VDC) and a 0 will turn the output off (open). Range: 0 - 8 This command uses the voltage on input 1 to calculate and set the max speed. The analog speed must be enabled for this command to work. This command is used in conjunction with the analog speed “;”, the analog speed lower limit “[“, and the analog speed lower limit “]” commands. This value must be set before motion be- gins. This command sets the number of clocks for the DPN10601 to send out following a G command. It is also used to set the registration index during and index on the fly move. Motion is not activated by this command; it only sets the index register . This command reads the thumbwheel switches to set the number of clocks for the DPN10601 to send out following a G command. For this command to work the thumbwheel enable bit must be enabled. Motion is not activated by this com- mand, it only sets the index register. This command is used in conjunction with the thumbwheel enabled “/” command.
36 P - Absolute position and analog position Format 1: P[value] Description: Range: -8388607 to +8388607 Format 2: P Description: S - Go slew Format : S Description: T - Motor current enabled Format: T[0 or 1] Description: This command uses the voltage on input 1 to calculate and set the number of clocks for the DPN10601 to send out following a G command. The analog position must be enabled for this command to work. Motion is not activated by this command, it only sets the register (N = P - Z). This command is used in conjunction with the analog position“:”, the analog position lower limit “{“, and the analog position lower limit “}” commands. This command calculates and sets the number of clocks for the DPN10601 to send out following a G command. Motion is not activated by this command; it only sets the register. (N = P - Z) This command will send clocks out to the DPN10601. The only commands that can stop the clocks are; “.” (stop motion) or “,” (soft limit). Motion can also be stoppedby using the limit switch inputs. The ramp profile is specified by the B (base speed), M (max speed), and A (acceleration/deceleration) commands. This command will control the On/Off output, which is designed to connect to the on/off input of Anaheim Automation’s step motor drivers. To energize and allow current to flow through the coil of the motor, set the value to 1. To de-energize and turn the current off to the motor, set the value to 0. This is a dedicated output, and not controlled with the output register.
37 Z - Position Format: Z[value] Description: This command sets the current position as a reference. This register can contain a positive or negative value but, cannot be changed while motion is in progress. Range: -8388607 to +8388607 ! - Error codes register Format : ! Description: This command requests the DPN10601 controller to get the current error code and print it to the screen. For a description of the error codes see page 39. $ - Version number register Format : $ Description: This command requests the DPN10601 controller to return its internal firmware version number. V - Verify Format: V[command] Description: This command can be used with most commands to verify the register contents. This is a read only command. Valid Commands are shown below. CommandDescription CommandDescription A Verify acceleration/deceleration OVerify outputs B Verify base speed TVerify motor current (1 is on, 0 is off) C Verify steps between outputs on the fly Z Verify position D Verify 1st output on the fly position ‘Verify index on the fly enabled** EA Verify encoder autocorrect enabled** (Verify output on the fly enabled** ED Verify encoder delay +Verify Direction EM Verify encoder motor ratio /Verify thumbwheel index enabled** EP Verify encoder position :Verify analog position enabled** ER Verify encoder retries ;Verify analog speed enabled** EW Verify encoder window [Verify lower analog speed value F Verify if controller is busy (1 is busy, 0 is not busy) ] Verify upper analog speed value J Verify jog speed ^Verify number of outputs L Verify Limits (1 is Hard, 2 is Soft, 3 is Hard and Soft, 0 is neither) { Verify lower analog position value M Verify max speed }Verify upper analog position value N Verify number of steps ** 1 is enabled, 0 is disabled
38 % - Verify address register Format : % (No address is needed before this function. @% will return the address) Description: This command requests the DPN10601 controller to return its internal address number to the PC or PLC. ‘ - Index on the fly enabled Format: ‘[0 or 1] Description: This command will either enable or disable the index on the fly function. To enable the function, use a 1. To disable the function use a 0. This command is used in conjunction with the number of steps “N” and go slew “S” commands. ( - Output on the fly enabled Format: ([0 or 1] Description: + - Clockwise Format: + Description: This command sets the direction output to clockwise. , - Soft Limit Input Bit Format: , Description: - - Counter-Clockwise Format: - Description: This command sets the direction output to counterclockwise. . - Stop Motion Format: . Description: This command will stop all motion. It can also be used to stop the current pro- gram that is running.This command will either enable or disable the output on the fly function. To enable the function, use a 1. To disable the function use a 0. This command is used in conjunction with the number of steps between outputs “C”, 1st output position “D”, and number of outputs “^” commands. This command will ramp the clocks down to base speed. The move type then determines what will happen. In a relative or absolute type motion the DPN10601 controller will continue to the set position and stop. In a slew type motion the DPN10601 controller will ramp down and stop. In a home type motion the DPN10601 controller will ramp down and run at base speed, until the home limit is activated.
39 / - Thumbwheel index enabled Format: /[0 or 1] Description: : - Analog position enabled Format: :[0 or 1] Description: ; - Analog speed enabled Format: ;[0 or 1] Description: [ - Analog speed lower limit Format: [[value] Description: Range: 1 - 50000 ] - Analog speed upper limit Format: ][value] Description: Range: 1 - 50000 This command will either enable or disable the ability to use the thumbwheel switches for indexing. This command will either enable or disable input 1 to be used to set the analog position. To enable the function, use a 1. To disable the function use a 0. This command is used in conjunction with the analog position lower limit “{“ and analog position upper This command will either enable or disable input 1 to be used to set the analog speed. To enable the function, use a 1. To disable the function use a 0. This command is used in conjunction with the analog speed lower limit “[“ and analog speed upper This command sets the lower limit that is used during the calculation following an M command for the analog speed input. This command is used in conjunction with the analog speed enabled “;” and max speed “M” commands. This command sets the upper limit that is used during the calculation following an M command for the analog speed input. This command is used in conjunction with the analog speed enabled “;” and max speed “M” commands.
40 ^ - Number of outputs during output on the fly Format: ^[value] Description: Range: 0 - 255 { - Analog position lower limit Format: {[value] Description: Range: 0 - 65535 } - Analog position upper limit Format: }[value] Description: This command sets the upper limit that is used during the calculation following a P command for the analog position input. This command is used in conjunction with the analog position enable “:” and absolute position “P” commands. Range: 0 - 65535 ~ - Set address register Format : ~[value] (No address is needed before this function. @~[value] will set the address) Description: This command sets the address for communication inside the DPN10601. Range: 0 - 99 This command sets the number of times output 1 will turn on during an output on the fly move. This command is used in conjunction with the output on the fly enabled “(“ command. This command sets the lower limit that is used during the calculation following a P ommand for the analog position input. This command is used in conjunction with the analog position enable “:” and absolute position “P” commands.