September 2012 L0104051 MDC151-012301 Series 12V, 30A Brushless DC Controller User’s Guide 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: [email protected](714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com ANAHEIM AUTOMATION
Page 2
September 2012 L0104052 MDC151-012301 Driver Features • Maximum Current Limit Setting from 10.0-30.0 Amps (peak) • Internal or External Potentiometer Speed Control • 0V to 5V External Voltage Speed Control • 2-Quadrant Operation • Hall Sensor Feedback • Constant Velocity Mode • Short Circuit Protection • Requires 10 - 15VDC • Speed Out • Fault Out • Run/Stop, Freewheel and Direction • Selectable Ramp Up • TTL-CMOS Compatible Inputs • Compact Size (6.25” x 3.28” x 1.65”) • Dual Mounting...
Page 3
September 2012 L0104053 Specifi cations Control Inputs: (TB1, Pins 1-3) TTL-CMOS Compatible Logic “0” = 0-0.8VDC Logic “1” = OPEN All three inputs (run/stop, freewheel, and direction) are pulled up through 20k Ohm resistors. Direction Control: (TB3, Pin 2) Logic “1” (open) - Clockwise Logic “0” - Counterclockwise Freewheel: (TB3, Pin 3) Logic “1” (open) - Motor is Enabled Logic “0” - Motor is de-energized and will coast Run/Stop: (TB3, Pin 4) Logic “1” (open) - Motor will not run and if running will come...
Page 4
September 2012 L0104054 Hall Sensor Power Output: 6.25V @ 30mA maximum. Typical current draw from hall sensor is 20mA. All three Hall Sensor inputs are pulled up through 20K ohm resistors. Open Loop/Closed Loop (Constant Velocity Mode) The driver can either be set for Open Loop or Closed Loop operation. Open Loop operation is used for applications where the speed of the motor needs to change according to the load. Closed Loop operation is used for applications where speed regulation is needed. Under...
Page 5
September 2012 L0104055 Anaheim Automation Motor Closed Loop Settings Motor CL1 CL2 CL3CL POTMAX SPD (RPM)MIN SPD (RPM) BLWR110S-15V-8000 On On On 80% 8000 500 BLWR111S-24V-10000 On On On 50% 10050 825 BLWR112S-24V-3700 On Off On 100% 3735 450 BLWR231D-36V-4000 On Off On 65% 4010 550 BLWR232D-36V-4000 On Off On 65% 4010 550 BLWR233D-36V-4000 On Off On 65% 4010 550 BLWR234D-36V-4000 On Off On 65% 4010 550 BLWR235D-36V-4000 On Off On 65% 4010 550 BLWR232S-24V-1350 Off Off Off 0% 1600 200...
Page 6
September 2012 L0104056 Step 1 2 3456 Phase A + Z - - Z + Phase B Z + + Z - - Phase C - - Z + + Z Hall A 1 1 0 0 0 1 Hall B 0 1 1 1 0 0 Hall C 0 0 0 1 1 1 Step 1 2 3456 Phase A - Z + + Z - Phase B Z - - Z + + Phase C + + Z - - Z Hall A 1 1 0 0 0 1 Hall B 0 1 1 1 0 0 Hall C 0 0 0 1 1 1 Step 1 2 3456 Phase A + Z - - Z + Phase B Z + + Z - - Phase C - - Z + + Z Hall A 1 1 1 0 0 0 Hall B 0 1 1 1 0 0 Hall C 0 0 1 1 1 0 Step 1 2 3456 Phase A - Z + + Z - Phase B Z - - Z + + Phase C + + Z - - Z Hall A 1 1 1 0 0...
Page 7
September 2012 L0104057 Terminal and Dip Switch Descriptions Pin # Description 1 Hall Sensor Power 2 Hall Sensor A 3 Hall Sensor B 4 Hall Sensor C 5 Hall Sensor Ground Pin # Description 1 Phase A 2 Phase B 3 Phase C 4 VIN 5 GND TB1: Motor Hall TerminalsTB2: Power and Motor Phase Terminals TB3: Control Inputs and Outputs Pin # Description 1 PG OUT 2 Direction 3 Freewheel 4 Run/Stop 5 Fault Out 6 VControl 7 GND SW # Description 1 INT/EXT SPEED 2 FLT LATCH 3 RAMP 1 4 RAMP 2 5 60/120 SW # Description 1 O/C...
Page 8
September 2012 L0104058 Motor Freewheel The motor freewheel feature allows the de-energizing of the motor phases. A high (open) input at this input causes the motor to run at the given speed, while a low at this input causes the motor to coast to a stop. Motor Run/Stop The motor run/stop feature allows the stopping of a motor by shorting out the bottom drives of the three phases. A low at this input allows the motor to run, while a high (open) input does not allow motor operation and if operating...
Page 9
September 2012 L0104059 Speed Output The PG OUT terminal (TB3 - pin 1) is used to determine the speed of the motor shaft. A 5V signal pulse out is shown at a rate of 4 pulses for 1 revolution of an 8-pole motor, 3 pulses for 1 revolution of a 6-pole motor, and 2 pulses for 1 revolution of a 4-pole motor. # Poles RPM 8 15 * PG OUT (in Hz) 6 20 * PG OUT (in Hz) 4 30 * PG OUT (in Hz) Heating Considerations The temperature of the heat sink should never be allowed to rise above 70° Celsius. If necessary,...