21 Page -Pressure relief valve- The water heater has a high-temperature shutoff switch built in as a standard safety feature (called a Hi-Limit switch) therefore a “pressure only” relief valve is required. • This unit does not come with an approved pressure relief valve. • An approved pressure relief valve must be installed on the hot water outlet. • The pressure relief valve must conform to ANSI Z21.22 or CAN 1-4.4 and installation must follow local codes. • The discharge capacity must be at least...
Page 22
22 Page TEMPERATURE REMOTE CONTROLLER -INCLUDED ACCESSORIES- 1. Take off the “Back plate” from the remote controller with a flat head screwdriver. (Fig. A and B) 2. Attach the “Back plate” on the wall with the two provided screws. (Fig. B) • This remote controller is NOT waterproof Do not install in high temperature environments, steamy conditions (such as a bath room), outdoors, in direct sunlight, or within the reach of children. Make sure the remote controller does not come into...
Page 23
23 Page 3. Tighten the two "Fork terminals" beneath the two "Remote controller terminal" screws on the back of the main body. (Fig. C-1) 4. Cut out the inlet for the remote controller cable from the bottom of the main body. (Fig. C-2) 5. Place the “Main body” back on the "Back plate", with the "Remote controller cable" running out of the bottom inlet. Remote controller terminals Fig. C-1 Two fork terminals Remote controller cable Inlet for the...
Page 24
24 Page 5. Pull the remote’s wires through the hole at the bottom of the water heater’s casing. 6. Properly attach the remote’s wires to the remote controller terminal on the computer board (No polarity). * Do NOT jump or short-circuit the wires, or computer will be damaged. 7. Replace Front Cover securely. 8. Wires used for the remote controller connection must be: • Minimum 20 gauge wire (No polarity) • Maximum 400 ft. (122 m) long Installation Installation Manual...
Page 25
25 Page EASY-LINK SYSTEM (Available on the 510U (T-D2U) model only) The 510U (T-D2U) model water heaters can be connected with other allowable heaters (see the table below) with communication cables to work as a multiple-unit manifold system. • The Easy-Link System allows up to 4 units to manifold together. • A communication cable (gray color) comes with each 510U (T-D2U) model. You can manifold from 2 to 4 units without the need for a multi-unit controller. A 4-unit system has full automatic...
Page 26
26 Page 5. Between the “PARENT” and the “CHILD-1” units: Connect the “PARENT” connector of the “PARENT” unit to the “1” connector of the “CHILD-1” unit using the supplied linking cable. 6. Between the “CHILD-1” and the “CHILD-2” units: Connect the “2” connector of the “CHILD-1” unit to the “1” connector of the “CHILD-2” unit. 7. Between the “CHILD-2” and the “CHILD-3” units: Connect the “2” connector of the “CHILD-2” unit to the “1” connector of the “CHILD-3” unit. 8. Verify that all cables are...
Page 27
27 Page (C) Examples of incorrect settings and /or connections CASE 1: Wrong DIPswitch setting on the "PARENT" unit CASE 2: Wrong connections between the "PARENT" unit and the "CHILD-1" unit • If you connect the “1" (or "2") connector of the “PARENT” unit to the “PARENT" (or "1") connector of the “CHILD-1” unit, the system will not work as an Easy-Link System. The units will operate as individual units. OR PARENT...
Page 28
28 Page CASE 3: Wrong connections between the "CHILD-1" unit and the "CHILD-2" unit • If you connect the “PARENT” connector of the “CHILD-1” unit to the “1” connector of the “CHILD-2” unit, the “CHILD-2” unit will operate as an individual unit, and will not be part of the Easy-Link System. CASE 4: Remote controller connected to incorrect unit • Remote controller has to be connected to the “PARENT” unit. If the remote controller is connected to a “CHILD” unit, it will only...
Page 29
29 Page MULTI-UNIT SYSTEM Multiple 510U (T-D2U) models can be combined for a Multi-Unit System, along with the multi- unit controller (Parts 9008300005 (TM-MC02)) and remote controller (9008172005 (TM-RE40)). Each set of multi-unit controller and remote controller can control from 2 units to 20 units for commercial or residential applications. For a 20-unit system, the computer can modulate between the usages of 15,000 BTU/h to 4.0 Million BTU/h. An individual cut-off switch is recommended for...
Page 30
30 Page APPLICATIONS -Space-Heating Applications- -Recirculation- *The recirculation pump is to be controlled by: -Dual-set aquastat (recommended w/timer) *The recirculation pump is to provide no less than 2 GPM (7.5 L/min) and no more than 4 GPM (15 L/min) through each activated unit in the system. • In order to purge air in water pipes within a closed-loop system, an air vent and air separator should be installed in the system. Required circulation flow rates are labeled next to each application...