Page 21
21 Page -Pressure relief valve- The water heater has a high-temperature shutoff switch built in as a standard safety feature (called a Hi-Limit switch) therefore a “pressure only” relief valve is required. • This unit does not come with an approved pressure relief valve. • An approved pressure relief valve must be installed on the hot water outlet. • The pressure relief valve must conform to ANSI Z21.22 or CAN 1-4.4 and installation must follow local codes. • The discharge capacity must be at least...
Page 22
22 Page REMOTE CONTROLLER CONNECTIONS 1. Disconnect power supply from the water heater. 2. Take off the water heater’s front cover. 3. Wires used for the remote controller connection must be: • Minimum 20 AWG wire (No polarity) • 9007666005 (TK-RE02) for 110 (T-KJr2) & 310 (T-K4) models Maximum 150 ft. long 9007603005 (TM-RE30) for 510 (T-D2) model Maximum 400 ft. long * For detailed connection to the remote controller, refer to the instructions that are packaged with the remote controller. 4....
Page 23
23 Page Installation Installation Manual PUMP CONTROL CONNECTIONS Available on the 510 (T-D2) model only The 510 (T-D2) model water heater can be used to control a recirculation pump. Proper pump control helps to preserve the life of the system and saves energy as well. The water heater pump control port is a “normally-open dry contact”, and therefore needs additional components to properly control a recirculation pump, such as a relay. To control a recirculation pump, connect the pump to a relay...
Page 24
24 Page EASY-LINK SYSTEM (Available on the 510 (T-D2) model only) The 510 (T-D2) model water heaters can be connected with other allowable heaters (see the table below) with communication cables to work as a multiple-unit manifold system. • The Easy-Link System allows up to 4 units to manifold together. • A communication cable (gray color) comes with each 510 (T-D2) model. You can manifold from 2 to 4 units without the need for a multi-unit controller. A 4-unit system has full automatic modulation...
Page 25
25 Page 5. Between the “PARENT” and the “CHILD-1” units: Connect the “PARENT” connector of the “PARENT” unit to the “1” connector of the “CHILD-1” unit using the supplied linking cable. 6. Between the “CHILD-1” and the “CHILD-2” units: Connect the “2” connector of the “CHILD-1” unit to the “1” connector of the “CHILD-2” unit. 7. Between the “CHILD-2” and the “CHILD-3” units: Connect the “2” connector of the “CHILD-2” unit to the “1” connector of the “CHILD-3” unit. 8. Verify that all cables are...
Page 26
26 Page (C) Examples of incorrect settings and /or connections CASE 1: Wrong DIPswitch setting on the "PARENT" unit CASE 2: Wrong connections between the "PARENT" unit and the "CHILD-1" unit Installation Installation Manual • Unless you change DIPswitch No. 1 of the “PARENT” unit to the “ON” position, the system will not work as an Easy-Link System. The units will operate as individual units. Communication cable Connectors Right bank of...
Page 27
27 Page CASE 3: Wrong connections between the "CHILD-1" unit and the "CHILD-2" unit CASE 4: Remote controller connected to incorrect unit Connecting two “PARENT” connectors together from two separate units may damage the computer board. The communication cable has a female end and a male end so it’s impossible to have a PARENT-to-PARENT connection with the communication cable. Do not splice or modify connectors.WARNING Installation Installation Manual • If you connect the “PARENT”...
Page 28
28 Page APPLICATIONS -Space-Heating Applications- -Recirculation- *The recirculation pump is to be controlled by: -Dual-set aquastat (recommended w/timer) or -"Pump Control Connections" 510 (T-D2) model only. (Refer to p.23.) *The recirculation pump is to provide no less than 2 GPM and no more than 4 GPM through each activated unit in the system. • This water heater is suitable for combination water (potable) heating and space heating and not suitable for space heating applications only. • In...
Page 29
29 Page • Priority Control Devices such as a flow switch, an Aquastat or other electronic controller can be used to prioritize the domestic water system over the heating system. • Follow all local codes, or in the absence of local codes, follow the most recent edition of the National Standard Code, ANSI Z21.10.3. • This illustration is a concept design only. The reference to the 1/8th hole in check is only for the State of Massachusetts. There are a wide variety of variations to the...
Page 30
30 Page INITIAL OPERATION IF YOU SMELL GAS: • Do not try to start the water heater. • Do not touch any electric switches; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. WARNING Operation 1.Once the above checks have been completed, please clean filter of any debris. Refer to p. 40 for instructions. 2.Fully open the manual water control...