1 Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide To obtain technical, warranty or service assistance during or after the installation of this water heater, call toll free 1-800-999-9515 When calling for assistance, please have the following information ready: 1. Model number 2.10 Digit product number 3. Serial number 4. Date of installation 5. Place of Purchase Water Heater Safety ........................................................................\...
Page 2
2 Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on you\ r appliance. Always read and obey all safety messages.This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you an\ d others. All safety messages will follow the safety alert symbol and either the w\ ord “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don’t immediately follow...
Page 3
3 INSTALLING YOUR WATER HEATER Consumer Information This water heater should be installed in accordance with the local code authority having jurisdiction, the power company or electric utility, and this installation manual. In the absence of local code requirements, follow the regulations set forth in the latest edition of The National Electric Code, NFPA 70. This is available from the following: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269 American National Standards...
Page 4
4 Figure 3 Residential Garage Installation Vehicle Stop Drain Drain Pan NOTE: The water heater shall be located so it is not subject to physical damage by moving vehicles or area fl ooding. State of California NOTE: The water heater must be braced, anchored, or strapped to avoid moving during an earthquake. Contact local utilities for code requirements in your area, visit http://www.dsa.dgs.ca.gov, or call 1-916-445-8100 and request instructions. IMPORTANT: The water heater should be located in an...
Page 5
5 Water System Piping Piping, fi ttings, and valves should be installed according to the installation drawing (Figure 4). If the indoor installation area is subject to freezing temperatures, the water piping must be properly insulated. Water supply pressure should be 50-60 PSIG and not exceed the maximum 80 PSIG. If the supply line pressure exceeds 80 PSIG, a pressure reducing valve (PRV) with a bypass should be installed in the cold water supply line. This should be placed on the supply to the...
Page 6
6 Please note the following: • The system should be installed only with piping that is suitable for potable (drinkable) water such as copper, CPVC, PEX or polybutylene. This water heater must not be installed using iron piping or PVC water piping. • Use only pumps, valves, or fittings that are compatible with potable water. • Use only full flow ball or gate valves. The use of valves that may cause excessive restriction to water flow is not recommended. • Use only 95/5 tin-antimony or other...
Page 7
7 IMPORTANT: When making condensation connections to the primary connection DO NOT over tighten. Overtightening could crack or damage the condensate drain pan. • Plastic pipe or tubing must be used to connect the condensate drain to a suitable drain or condensate pump. • Condensate drain lines should be installed in conditioned areas only. Install approved insulation on the condensate drain lines to prevent condensation from forming on the outside of the drain lines. Condensation drain lines...
Page 8
8 For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF VALVE” (Figure 8). To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and pressure relief protective equipment required by local codes, but no less than a combination temperature and pressure relief valve certifi ed by a nationally recognized testing laboratory that maintains periodic...
Page 9
9 If you lack the necessary skills required to properly install the electrical wiring to this water heater , do not proceed but have a quali fi ed electrician perform the installation. When making the electrical connections, always make sure: • The electrical service provides 240 VAC to the water heater for proper operation. DO NOT use 208 VAC. • Wire sizes and connections comply with all applicable codes or in the absence of local or state codes follow NFPA-70, the National Electrical...
Page 10
10 Water Heater Location □ Centrally located with the water piping system. □ The fl ooring beneath the water heater must be able to support the weight of the water heater when fi lled with water (Table 1). □ Located indoors (such as a basement or garage) and in a vertical position. Sheltered from freezing temperatures. □ Provisions made to shelter the area from water damage. Metal drain pan installed and piped to an adequate drain. □ Sufficient room to service the water heater. □...