Home > Aluratek > Audio-visual interconnect box > Aluratek 2 POWER RECEPTACLE 110V 4 SNAPIN CONNECTORS DS901120 User Guide

Aluratek 2 POWER RECEPTACLE 110V 4 SNAPIN CONNECTORS DS901120 User Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Aluratek 2 POWER RECEPTACLE 110V 4 SNAPIN CONNECTORS DS901120 User Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 43 Aluratek manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121/
    //
    /Sec
    SecSec
    Sectional Plates for PNP415/417C
    tional Plates for PNP415/417Ctional Plates for PNP415/417C
    tional Plates for PNP415/417C 
      
      
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    1 
    Welcome! 
    We greatly appreciate your purchase of the DS901-120/121 Sectional Plate 
    for PNP415/417C Interconnect Box. We are sure you wi ll find it reliable and 
    simple to use. Superior performance for the right pri ce, backed by solid 
    technical and customer support is what ALTINEX has to o ffer. 
    We are committed to providing our customers with  
    Signal Management Solutions
    ® to the most demanding audiovisual 
    installations at very competitive pricing and we welc ome you to join the 
    ranks of our many satisfied customers throughout the wo rld. 
    1. Precautions and Safety Warnings 
    Please read this manual carefully before using your DS901-120/121 Sectional 
    Plate. Keep this manual handy for future reference.  These safety instructions 
    are to ensure the long life of your DS901-120/121 an d to prevent fire and 
    shock hazards. Please read them carefully and heed all  warnings. 
    1.1 General  · 
    Qualified ALTINEX service personnel, or their authori zed 
    representatives, must perform all service. 
    1.2 Installation Precautions  ·  
    For best results, place the DS901-120/121 on a flat, l eveled surface in a 
    dry area away from dust and moisture. 
    ·  To prevent fire or shock, do not expose this unit to w ater or moisture. 
    Do not place the DS901-120/121 in direct sunlight, n ear heaters, or 
    heat-radiating appliances, or near any liquid. Exposu re to direct 
    sunlight, smoke, or steam can harm internal components . 
    · Handle the DS901-120/121 assembly carefully. Dropping  or jarring can 
    damage the unit. 
    ·  To turn off the main power, disconnect the power cor d, which powers 
    the AC socket on the DS901-120/121 pop-up panel. The  power outlet 
    used should be installed as near to the equipment as pos sible and should 
    be easily accessible. 
    ·  ALTINEX recommends using wall outlets with a Ground Fa ult Circuit 
    Interrupter (GFCI) for maximum protection. 
    ·  Install all cables according to the instructions. Do  not force or pull out 
    any cable or power cord that is attached to the DS90 1-120/121 
    1.3 Cleaning  · 
    Surfaces should be cleaned with a dry cloth. Never u se strong 
    detergents or solvents, such as alcohol or thinner. Do  not use a wet 
    cloth or water to clean the unit. 
    1.4 FCC Notice  ·  
    This device complies with Part 15 of the FCC Rules. O peration is 
    subject to the following two conditions: (1) This devi ce may not cause 
    harmful interference, and (2) this device must accep t any interference 
    received, including interference that may cause unde sired operation. 
    · This equipment has been tested and found to comply wit h the limits for 
    a Class A digital device, pursuant to Part 15 of the  FCC Rules. These 
    limits are designed to provide reasonable protection a gainst harmful 
    interference when the equipment is operated in a co mmercial 
    environment. This equipment generates, uses, and can ra diate radio 
    frequency energy and, if not installed and used in ac cordance with the 
    instructions found herein, may cause harmful interfe rence to radio 
    communications. Operation of this equipment in a re sidential area is 
    likely to cause harmful interference in which case t he user will be 
    required to correct the interference at his own expe nse. 
    · Any changes or modifications to the unit not expressly  approved by 
    ALTINEX, Inc. could void the user’s authority to op erate the 
    equipment. 
     
     
     
    2. Installation Procedures 
    See Diagrams 2 through 7 of the online manual for in stallation details. 
    Step 1.  Disconnect all power cords that are connecte d between an AC receptacle and the PNP unit being modified. 
    Step 2.  If the panel that is being replaced has any c ables attached to it, disconnect those as well. This wou ld include all power and signal cables. 
    Step 3.  Remove the top of the PNP unit. There are f our screws holding the top of the unit to the chassis. 
    Step 4.  Lift the top of the PNP (including table cu tout) by lifting straight up on the cutout.  
    Step 5.  Slide out the existing panel by pulling strai ght up on the panel. 
    CAUTION:  If there are cables attached to the panel, c arefully guide them up through the bottom of the PNP chassis. Depending on the number 
    and size of the cables and connectors, it may be necessa ry to feed each one through the opening in the bottom individually. 
    Step 6.  Route DS901-120/121 cables down through the  top of the PNP. Feed the cables through the opening at the bottom of the chassis. The cables must exit 
    the chassis on the same side as the panel. The cables m ust not cross to the opposite side or past the gas spring.  
      HINT:  Use two people if necessary. One gently pulls th e cables from the bottom while the other feeds them from the top. 
    Step 7.  Replace the top of the PNP using the same fou r screws.  
    Step 8.  Connect all DS901-120/121 cables to their a ppropriate sources/destinations.  Reconnect any cables  disconnected at the beginning of the installation. 
    Step 9.  The DS901-120/121 is ready for operation.    
    3. Limited Warranty/Return policies 
    Please see the ALTINEX website at www.altinex.comfor details on warranty and return policies.   
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    2 
    4. Technical Specifications 
    Specifications are subject to change. See www.altinex.com for up-to-date information. 
     
      Features/Description  DS901-120/121 
     DS901-120  Pass-Through Connections 
     Video (1)  15-pin HD female to male 
     Power (2)  NEMA 5-15R to NEMA 5-15P 
     Network (2)  RJ-45 female to RJ-45 male 
     Modem (1)  RJ-11 female to RJ-11 male 
     Stereo Audio (1)  3.5mm female to 3.5mm male 
     DS901-121  Pass-Through Connections 
     Power (2)  NEMA 5-15R to NEMA 5-15P 
    Table 1. DS901-120/121 General 
     
    Mechanical  DS901-120/121 
    Height  3.435 in. (87.3 mm) 
    Width  2.862 in. (72.7 mm) 
    Finish  Black Anodize 
    T° Operating   10 °C-35 °C 
    T ° Maximum  40 °C 
    Humidity 
    90% non-condensing 
    Table 2. DS901-120/121 Mechanical  
      Electrical  DS901-120/121 
    Power Rating  
    (pass through  AC power)  120VAC, 60Hz, 5A 
    Table 3. DS901-120/121 Electrical         
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    3 
     
     
    5. About Your DS901-120/121 
    The DS901-120 and DS901-121 are sectional plates for use with the PNP415/417C Pop ‘N Plug Interconnect B ox.  The sectional plates offer female receptacles in 
    the pop up panel and six foot long cables running fro m the panel down to their equivalent male plugs at the opposite end. 
    DS901-120 Audio/Video Sectional Plat
    e 
    The DS901-120 is preconfigured with 2 AC power rece ptacles a single 15-pin HD (computer video) connector, 2 RJ-45 (network) connectors, one RJ-11 (modem) 
    connector and one 3.5mm stereo audio connector.  
    DS901-121 Customizable Sectional Plate
     
    The DS901-121 is preconfigured with 2 AC power rece ptacles and five blank positions that may be custom configured. Four of the custom positions may be 
    configured with any combination of available audio,  video and/or control connector/cable assemblies. These  include RJ-45 (UTP) connectors, RJ-11 (modem) 
    connectors, 3.5mm audio connectors, LED indicators,  or any other connectors that fit the size of the opening and are available from ALTINEX. The remaining 
    blank position may be fitted with a 9-pin connector  or a 15-pin HD connector. 
         
    NOTE: The default DS901-121 connector installation is shown in the above diagram.  Various combinations of connectors, al ong with the applicable cable 
    types, may be selected for customization at the time of purchase. 
    Please, see the ALTINEX website 
    www.altinex.com for specific customization options and instructions. 
     
    110VAC x2 POWER
    15-pin
    HD VGA
    RJ-45 (network) x2
    RJ-11 (modem)
    3.5mm AUDIO
    110VAC POWER
    Configurable Snap-Ins x4
    BLANK - Custom
    Configurable
    BLANK - Custom
    (DB9/15-pin HD)
    DS901-120 
    DS901-121       
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    4 
    6. Application Diagrams  
    Diagram 1: Typical Setup 
       
    DS901-120
    REVERSE SIDE
    OF PNP
    DS901-121
       
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    5 
    Diagram 2: Installation Step 1 
                               
    Diagram 3: Installation Step 2 
       
    Remove 4 screws.
    The screws are located at the top 
    of the side metal. There are two (2) 
    screws per side.
     
    Remove Top Cover
    4 screws removed 
    in previous step.
    Remove the top cover 
    by lifting straight up.
       
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    6 
    Diagram 4: Installation Step 3 
                               
    Diagram 5: Installation Step 4 
       
    Slide out existing panel.
    If the existing panel has cables attached, 
    carefully guide them through the 
    opening at the bottom of the unit.
     
    Feed DS901-120/121 Cables
    Route the cables down from the top 
    of the PNP chassis. Make sure the cables 
    feed through the bottom of the unit on 
    the same side as the new panel.
       
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    7 
    Diagram 6: Installation Step 5 
                               
    Diagram 7: Installation Step 6 
       
    Install DS901-120/121 Panel
    Panel Guides
    Panel Guides
    Slide the DS901-120/121 into 
    the PNP chassis using the 
    panel guides as shown.
     
    Replace Top Cover
    Replace the top cover by  aligning the holes from the top cover bracket with the 
    mounting holes in the side  
    panels.
    Reinstall the four (4) 
    screws removed at the 
    beginning.
    Align (x4)
       
    						
    							DS901
    DS901 DS901
    DS901-
    --
    -120/121
    120/121120/121
    120/121 
      
     User’s Guide 
      
     
    400-0441-003 
     
             
    8 
    7. Operation  
    7.1 General Operation  
    The DS901-120/121 does not require any adjustments for proper operation. 
    Once installed, the DS901-120/121 will operate troub le free with no user 
    intervention. 
    7.2 Power/Signal Connections 
    Connect external devices to the appropriate connect or on the 
    DS901-120/121.  Remember, the devices plugged into t he AC power 
    connectors should not draw more than 5A AC. 
    8. Troubleshooting Guide 
    We have carefully tested and have found no problems i n the supplied 
    DS901-120/121. However, we would like to offer sugge stions for the 
    following: 
    ·  Please make sure that the highest quality network cabl es are used. 
    · Make sure that no cable or power cord is damaged or p inched. If 
    there has been damage to the unit, do not use the DS 901-120/121. 
    Please contact ALTINEX at (714) 990-2300 to have the  unit repaired. 
       
    						
    All Aluratek manuals Comments (0)

    Related Manuals for Aluratek 2 POWER RECEPTACLE 110V 4 SNAPIN CONNECTORS DS901120 User Guide