PneuCal III The 2500T offers simplistic set-up to make your job easier. The Altek PneuCal III is a highly accurate, digital calibrator for pneumatic field instrumentation, including valve actuators, P/I transmitters, controllers, gauges, switches and recorders. It is especially suitable for checking 3 to 15 PSI systems. Its dual precision regulators enable output of set and variable pressures to control devices, while the switching manifold allows fast selection among the pressure ports. The unit simultaneously displays pressure and mA, and has a built-in loop power supply. Accuracy is ± 0.035% of full scale for all ranges. Optional external sensors measure other pressure ranges. Each Unit Includes: Built - In Switch Testing, AC Adapter/Charger, Test Leads, Hard Shell Carrying Case, Instructions, Built -in Pressure and Vacuum Pumps. 663 PNEUMATIC CALIBRATOR SPECIFICATIONS Features: nTwo Built-In Pumps Ð Vacuum and Pressure n High Accuracy Ð 0.035% FS n1-51 mA Inputs n Switch Test Inputs n 100 PSID Internal Sensor nRead up to 10,000 PSI With Optional External Sensor nBuilt-In 24 VDC Loop Power nTemperature Compensated From -10û to 50ûC (13û to 122ûF) nSelectable Engineering Units nJust 18 Pounds nDual Digital Display Ð PSI and mA nGauge, Differential, or Vacuum Modes Unless otherwise indicated, all specifications are referred to an ambient temperature of 23ûC ±1ûC (72ûF ±2ûF). Pressure Ranges/Resolution: -5.00 to 100.00 PSI, -34.47 to 680.00 kPa, VAC to 10,000 PSI with optional modules Pressure Accuracy: ±0.035% FS PSI (over -10 to +50ûC range) Pressure Engineering Units: PSI; Pa; kPa; MPa; BAR; mBAR; atm; kgf/cm 2; mm Hg; in Hg @ 0ûC and 15ûC, in H 2O: 4ûC,15ûC, 20ûC, 23ûC; mm H20 @ 4ûC and 23ûC; cm H2O @ 4ûC and 23ûC Electrical Engineering Units: mA; % of 4-20 mA; % of 10-50 mA Electrical Input Connections: Double insulated, full-size banana jacks mA Input Range: 1-51 mA mA Resolution: 0.001mA mA Accuracy: ±0.01% FS Temperature Effect: 0.005%/ûC (mA Input only) Loop Power: 24 VDC, ±20%, 25 mA max. (When loop power is enabled, the discharge rate on the batteries exceeds the charging capacity of the 16 VDC adapter.) Switch Test: Dry contacts only. (Display will freeze when switch test inputs change state. Press RESET key to resume normal operation.) Operating Temperature: -10ûC to 50ûC (13ûF to 122ûF) Storage Temperature: -30ûC to 85ûC (-22ûF to 185ûF) Zero Adjustment: Via front panel push-button (pressure only) Display: 2-line,16 character alpha-numeric display Power: Internal Ni-Cd batteries or 16 VDC adapter. (To charge battery the unit has to be powered off.) Battery Life (typical): 23 hrs. (1 hr. with 24 VDC transmitter power at 20 mA) Dimensions (h x w x d): 7x18.5x15.5 PHONE: 1-800-322-5835 ¥ FAX: 716-349-3510E-MAIL: [email protected] ¥ WEB: www.altekcalibrators.com
PRESSURE MODULE SPECIFICATIONS MODPAK 91 MODULE HOLDER MODULES Gauge Pressure Modules Model Range Accuracy Media 90-5G 5 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-10G 10 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-30G 30 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-100G 100 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-300G 300 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-500G 500 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-1,000G 1,000 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-2,500G 2,500 PSIG ±0.025% Rdg +0.01% FS 316SS Compatible 90-5KG 5,000 PSIG ±0.1% FS 316SS Compatible 90-10KG 10,000 PSIG ±0.1% FS 316SS Compatible ÒDual SensorÓ Pressure Module Model Range Accuracy Media 90-10G/2500G 10/2,500 PSIG ±0.025% Rdg +0.01%FS 316SS Compatible Differential Pressure Modules Model Range Accuracy Media 90-10WD ±10 H 2O Diff. ±0.025 in. H2O Clean Dry Gasses 90-5D 5 PSID ±0.025% Rdg +0.01% FS 316SS High/Dry Gas Low 90-15D 15 PSID ±0.025% Rdg +0.01% FS 316SS High/Dry Gas Low 90-30D 30 PSID ±0.025% Rdg +0.01% FS 316SS High/Dry Gas Low 90-100D 100 PSID ±0.025% Rdg +0.01% FS 316SS High/Dry Gas Low Absolute Pressure Modules Model Range Accuracy Media 90-15A 15 PSIA ± 0.05% FS 316SS Compatible 90-30A 30 PSIA ± 0.05% FS 316SS Compatible Vacuum Modules Model Range Accuracy Media 90-15V VAC to 0 PSIG ± 0.05% FS 316SS Compatible 90-15C VAC to 15 PSIG ± 0.05% FS 316SS Compatible PHONE: 1-800-322-5835 ¥ FAX: 716-349-3510E-MAIL: [email protected] ¥ WEB: www.altekcalibrators.com