    DATA SHEET 587 
    GENERAL DESCRIPTION
    ALTEK
    MODEL 587
    DIGITAL MULTIMETER
    The  Altek Model 587 is an industrial grade 41/2
    digit (20,000 count) highly accurate and reliable
    hand-held multimeter .  Its combination of durability
    and features makes this multimeter a versatile
    solution for all industrial and commercial
    applications.  
    The Model 587 uses low power CMOS
    technology with a LSI circuit incorporating a double
    integrating  A/D converter for accuracy and reliability .
    The Model 587 measures DC voltage and current,
    true RMS  AC voltage and current, resistance,
    capacitance, frequency , and diode forward voltage.
    The meter also has a beeper for continuity checking.
    The basic DC accuracy of this meter is  ±0.05% of
    reading, equaling or exceeding that of many 
    higher-priced DMMs.  In addition, the 4
    1/2digit,
    20,000-count display features large 1, high 
    contrast digits for easy reading from a distance. 
    This high-performance meter also makes true 
    RMS  AC measurements on non-sinusoidal signals.
    ADDITIONAL INFORMATION
    OTHER PRODUCTS: Altek designs and
    manufactures fast, accurate instruments for
    measurement, generation and simulation of virtually
    every process control signal. Consult our factory
    directly or contact your local stocking representative
    to order precise, low cost Milliamp Calibrators,
    Voltage Sources,  Thermocouple Sources, R TD
    Simulators, Frequency Calibrators and Pressure
    Pumps, Indicators & Calibrators.  Altek also 
    produces calibrators for custom ranges and unique
    applications.  New models are frequently added to
    the  Altek family to meet all of your critical calibration
    requirements.
    LIFETIME WARRANTY PROGRAM: Our equipment
    is guaranteed against defective material and
    
    EXTRA LARGE LCD (1.3 x 2.6 Inc
    hes)
    1 Digits
    TRUE RMS
    0.05% B ASIC DC A CCURACY
    EXCEPTIONAL FUNCTIONALITY
    DC and AC voltage
    DC and AC current
    Resistance
    Capacitance
    Frequency
    Continuity check
    Diode test
    Data hold
    Auto power-off
    DESIGNED FOR SAFETY  TO IEC 1010
    R UGGED AND RELIABLE
    workmanship (excluding batteries and test leads) for a
    period of one year . For a lifetime warranty: (1) Simply
    register the unit upon receipt by completing and
    returning the productÕ s Warranty Registration Card. 
    (2) Once a year , send the unit to any  Altek authorized
    distribution center for re-certification. Claims under
    warranty can be made by returning the equipment
    prepaid to any authorized  Altek distributor. Altek will
    repair , re-calibrate or replace free of charge any unit
    found to be defective or out of calibration at any time
    between re-certification intervals.  The liability of Altek 
    is restricted to that given under our guarantee. 
    No responsibility is accepted for damage, loss or other
    expense incurred through sale or use of our equipment.
    Under no condition shall  Altek be held liable for any
    special, incidental or consequential damage.
    SPECIFICATIONS
    (Unless otherwise indicated, specifications are for 1 year
    in ± (% of reading + number of digits) @ 23 ¡C)
    General
    BATTERY: 9V, (1604) battery
    LOW BATTERY INDICATION: Indication on the display
    when to replace the battery
    OPERATING TEMPERATURE RANGE: 32¡F to 104 ¡F
    (0¡ C to 40 ¡C)
    STORAGE TEMPERATURE RANGE: 14¡F to 122 ¡F 
    (-10¡ C to 50 ¡C)
    OPERATING ALTITUDE RANGE: Up to 6,500 feet
    STORAGE ALTITUDE RANGE: Up to 32,800 feet 
    RELATIVE HUMIDITY: Maximum of 80% up to 87.8 ¡F
    (31¡ C) decreasing linearly to 50% 
    at 104¡F (40¡C)
    FUSES: 0.3A/250V, (5x20mm), 10A/250V , (6x25mm)
    OVERALL SIZE: 7.48 x 3.47 x 1.34 inches 
    (190 x 88 x 34 mm)
    WEIGHT: 9.5 oz (270 g) (excluding test leads)
    ¥
    ¥ ¥
    ¥
    ¥
    ¥ 
    						
    							©June 2000 Altek Industries Corp 
    100908-900 Rev A
    ORDERING INFORMATION Part No.
    Industrial Grade Digital Multimeter 587
    Included with each Model 587 are: Protective rubber boot with probe holder
    Test leads
    Carrying strap
    Data Sheet 587
    Instruction manual
    Certificate of Conformance and Lifetime W arrantyAVAILABLE FROM
    Specifications subject to change without noticeOPTIONAL ACCESSORIES Part No.
    CARRYING CASE 09-3784
    DC Voltage
    Range Resolution Accuracy Input ImpedanceMax Input
    200mV 10uV 0.05% + 3 10M ½230 VDC or AC RMS 
    2V 100uV  0.05% + 3 10M ½
    20V 1mV 0.05% + 3 10M ½1000 VDC
    200V 10mV 0.05% + 3 10M ½or 750 Vrms
    1000V 100mV 0.1% + 5 10M ½
    AC Voltage  (40HzÐ400Hz
    Range Resolution Accuracy    Input ImpedanceMax Input
    200mV 10uV 0.8% + 20 10M ½230 VDC or AC RMS  
    2V 100uV 0.8% + 20 10M ½
    20V 1mV 0.8% + 20 10M ½1000 VDC
    200V 10mV 0.8% + 20 10M ½or 750 Vrms
    750V 100mV 1.0% + 50 10M ½
    AC V oltage is displayed as true RMS.
    DC Current Range Resolution Accuracy Burden Voltage Max Input20mA 1uA 0.5% + 2 0.2A, 300mA/
    200mA 10uA 0.8% + 5 < 0.2V 250V fused 10A 1mA 2.0% + 10 10A Range: 10A/ 250V fused
    Maximum current for the 10A range is 10Afor 10 seconds at 15 minute intervals. 
    AC Current  (40HzÐ400Hz)
    Range Resolution Accuracy Burden Voltage Max Input20mA 1uA 1.0% + 20 0.2A, 300mA/
    200mA 10uA 1.0% + 20 < 0.2V 250V fused 10A 1mA 2.0% + 20 10A Range: 10A/ 250V fused
    Maximum current for the 10A range is 10Afor 10 seconds at 15 minute intervals.
    AC Current is displayed as true RMS for crest factors less than 5.
    Resistance Range Resolution Accuracy Open Circuit Voltage Input Protection200 ½ 0.01½ 0.1% + 5
    2k ½ 0.1½ 0.1% + 2
    20k ½ 1½ 0.1% + 2 < 3V 230 VDC or
    200k ½ 10½ 0.1% + 2 AC RMS
    2M ½ 100½ 0.1% + 2
    20M ½ 1k½ 0.3% + 10
    Note: T o obtain maximum accuracy on the 200 ½range, short the test leads to obtain the resistance of the test leads, \
    and subtract this 
    resistance from the measured reading.
    Capacitance
    Range Resolution Accurac y
    20nF 1pF 2.0% + 10
    200nF 10pF 2.0% + 10
    2uF 0.1nF 2.0% + 10
    20uF 1nF 2.5% + 30
    T esting Signal: 400Hz, 40mV rms Frequency
    Range Resolution Accuracy20kHz 1Hz 1.0% + 20
    200kHz 10Hz 1.0% + 20
    Signal range: 200mV Ð 30V rms, Input protection: 230Vrms
    Continuity Check Range Resolution Continuity Tone Open Ckt. V Input Protectio n
    2k ½ 0.1½ < approx. 30½ < 3V 230 VDC or AC RMS
    Diode Test Range Resolution Test Current Input Protection2V 100uV 1mA 230 VDC or AC RMS
    Displays forward voltage in V olts 
    						