    							DATA SHEET 536 
    GENERAL DESCRIPTION
    ALTEK
    MODEL 536
    CLAMP-ON METER
    Do More with One Tool
    The Altek Model 536 is a rugged, reliable, clamp meter with
    greater versatilty than clamp meters that measure only AC
    current. Measure AC Current, DC current, AC and DC volts,
    frequency, ohms plus check continuity. Troubleshoot
    industrial, commercial, hospital and residential electrical
    and HVAC systems with the 536. This versatile clamp
    meter offers true-rms sensing and MAX hold for measuring
    inrush current or the maximum load on a circuit. The Model
    536’s combination of true-rms measurements, rugged
    construction, and reliable performance makes this meter
    indispensable for troubleshooting various problems
    associated with non-linear loads.
    True-RMS Readings
    The Model 536 displays the true-rms value of AC
    measurements. This feature is highly desirable for today’s
    engineers and technicians working with signals that
    contain harmonic currents caused by non-linear loads.
    Virtually all electronic equipment falls into this category –
    switching power supplies (UPS), PCs, printers, HID
    lighting, variable speed motor drives, and other types of
    equipment that draw current in short pulses. Average-
    sensing meters cannot accurately measure currents
    containing harmonics which cause distorted waveforms.
    Average-sensing meters can only accurately measure pure
    sine waves. One measure of waveform distortion is Crest
    Factor (CF), the ratio of the peak to the rms value of the
    wave. CF for a pure sine wave is 1.414. CFs other than
    1.414 indicate the presence of harmonic current flow.
    Altek’s true-rms Model 536 gives correct readings for any
    wave shape, within the instrument’s CF specifications.
    Frequency
    Frequency can be used to determine the output 
    frequency of variable speed drives, to set the governor of
    an engine generator, or to detect third harmonic currents
    (180 Hz) in the neutral of a three-phase system.
    ALTEK INDUSTRIES CORP
    
    • TRUE RMS (current and voltage)
    • DC CURRENT & VOLTAGE
    • FREQUENCY
    • RESISTANCE & CONTINUITY BEEPER
    • AUTO AND MANUAL RANGING WITH DATA HOLD
    • DUAL DISPLAY(4000 count digital display,
    41 segment analog bar graph)
    • MIN/MAX/AVERAGE RECORDING
    • EASY SINGLE-HANDED OPERATION
    • SAFETY-DESIGNED HAND GUARD
    • DESIGNED FOR SAFETY TO IEC 61010-1
    • RUGGED AND RELIABLE
    • SEALED, SPLASH-PROOF AND DUST-PROOF CASE
    Designed for Heavy Duty Use
    The jaw opening can handle two parallel 500 MCM cables, and
    the protective hand guard helps prevent accidental contact
    with conductors. The 536 is built extra strong to withstand
    heavy duty, job site abuse.
    Easy-To-Use
    Simple, one touch push-buttons make the Model 536 clamp
    meter easy to use.
    Analog/Digital Display
    The extra large LCD combines an accurate digital display with
    a fast analog bar graph for quick indication of varying signals.
    The digital display, updating four times per second, displays
    readings while the bar graph, updating 20 times per second,
    displays a quick view of the signal being measured.
    Data Hold
    Obtain readings in difficult areas where you can’t see the
    display.
    Auto Power Off
    Preserves battery life by automatically shutting the unit off
    after ten minutes of inactivity. Disable the power off mode of
    the Model 536 by pressing the ON/OFF pushbutton once.
    Max/Min/Avg
    Monitor the fluctuations in a measurement and record the
    average value over time.
    Soft
    Provides stable readings when loaded currents are fluctuating.
    Displays a running three-second average.
    Crest
    Measures the instantaneous half-cycle peak value of current
    waveforms. The ratio of the instantaneous half-cycle peak
    current value to the RMS current value is the Crest Factor,
    which can be an indicator of the presence of harmonics.
    DC Ampere Measurement
    Using Hall-effect technology, the 536 accurately measures AC
    and DC amperes without disturbing the test circuit. Push a
    button for fast Zero adjustment to measure DC amperes. 
    						
    							© June 2000 Altek Industries Corp., 
    100908-900 Rev A
    AVAILABLE FROM
    General
    DISPLAY: Digital 4000 counts (3 3
    /4 digits), [Hz: 9999 counts]
    Updates four times/sec
    Analog 41 segment bar graph, Updates 20 times/sec
    MAXIMUM CONDUCTOR SIZE: 2.01 (51 mm)
    MAXIMUM JAW OPENING: 2.05 (52 mm)
    MAXIMUM CONDUCTOR VOLTAGE: 600V rms
    AC Voltage
    Common Mode Rejection Ratio: > 80 dB, dc to 60 Hz
    DC Voltage Normal Mode Rejection Ratio: > 11 dB, at 50 Hz or 60 Hz
    Common Mode Rejection Ratio: > 84 dB, at dc, 50 Hz, or 60 Hz
    CREST FACTOR, CONTINUOUS WAVEFORM (45 HZ TO 65 HZ, LESS THAN
    1000A PEAK): 1.4 to 2.0 – add 20 digits to accuracy below 100A
    2.0 to 3.0 – add 1% to accuracy +20 digits below 100A
    3.0 to 5.0 – add 2% to accuracy +20 digits below 100A
    ADJACENT CONDUCTOR EFFECT: Maximum is 1% of current in adjacent conductor
    OPERATING TEMPERATURE  RANGE: 14°F to 131°F (-10°C to 55°C)
    STORAGE TEMPERATURE  RANGE: -4°F to 140°F (-20°C to 60°C)
    RELATIVE HUMIDITY: 0% to 80% at 104°F (30°C), 70% at 122°F (50°C)
    BATTERY: 9V, (NEDA 1604)
    BATTERY LIFE: 80 hours typical (alkaline)
    SAFETY STANDARDS: UL1244, IEC 61010-1 (Over voltage Category II), CSA
    C22.2 No. 231, ANSI/ISA (Appropriate Parts) S82, VDE 0411, and CE-certified
    OVERALL SIZE: 1.73 H x 3.84 W x 9.65 L (4.39 cm x 9.75 cm x 24.5 cm)
    WEIGHT: APPROX: 1.21 lb (545g)AC CURRENT:
    Amperes1
    Range Resolution Accuracy20.30A to 39.99A 0.01A ±(8% + 30)        20 Hz – 30 Hz3±(4% + 30)        30 Hz – 45 Hz4±(3% + 20)        45 Hz – 65 Hz
    ±(4% + 30)        65 Hz – 1 KHz
    0.30A to 399.9A 0.1A ±(8% + 3) 20 Hz – 30 Hz
    3±(4% + 3)        30 Hz – 45 Hz4±(3% + 2)        45 Hz – 65 Hz
    ±(4% + 3)        65 Hz – 1K Hz
    400A to 700A 1A Not Specified      20 Hz – 30 Hz
    3±7%  0 Hz – 45 Hz4±5%           45 Hz – 65 Hz
    ±7%           65 Hz – 1K Hz
    1Sine Wave, measured with conductor centered at alignment marks and 
    battery life indication greater than 40 hours at meter power up self test
    2RMS Min/Max: Add 10 counts3AVG only, 2.5A and above RMS Min/Max: Add 2% of reading41A and above
    INSTANTANEOUS AMPERES (PEAK MODE)1:
    Range Resolution Accuracy
    0.4A to 39.99A 0.2A ±(4% + 40)        20Hz – 30Hz
    2
    ±(4% + 30)        30Hz – 45Hz3
    ±(3% + 30)        45Hz – 65Hz
    ±(4% + 30)        65Hz – 1KHz
    0.4A to 399.9A 2A ±(4% + 4)          20Hz – 30Hz
    2
    ±(4% + 3)          30Hz – 45Hz3
    ±(3% + 3)          45Hz – 65Hz
    ±(4% + 3)          65Hz – 1KHz
    400A to 599A 4A ±4%           20Hz – 30Hz
    2
    ±4%           30Hz – 45Hz3
    ±3%           45Hz – 65Hz
    ±4%           65Hz – 1KHz
    600A to 999A 4A ±7%           20Hz – 30Hz
    2
    ±7%           30Hz – 45Hz3
    ±7%           45Hz – 65Hz
    ±7%           65Hz – 1KHz
    1Sine Wave, measured with conductor centered at alignment marks and 
    battery life indication greater than 40 hours at meter power up self test
    22.5A and above31A and above
    FREQUENCY1:
    Range Resolution Accuracy
    0.5 Hz to 999.9 Hz 0.1 Hz ±(0.2% + 3)
    1000 Hz to 9999 Hz 1 Hz ±(0.2% + 3)
    1Sine Wave, measured with conductor centered at alignment marks, and
    battery life indication greater than 40 hours at meter power up self test
    DC CURRENT:
    Range Resolution Accuracy
    0.30A to 39.99A 0.01A ±(2% + 30)
    0.3A to 399.9A 0.1 A ±(2% + 10)
    400A to 700A 1A ±(2% + 10)
    With Current Autorange: Trigger level, 5 Hz to 1,500 Hz, 0.7A RMS 
    or more, peak current
    With Manual Ranging: Trigger threshold, 10 Hz to 1,000 Hz
    40A Range – 6A RMS or more
    400A Range – 40A RMS or more
    Specifications subject to change without notice
    AC VOLTAGE (TRUE RMS) / DC VOLTAGE:
    Accuracy
    Range Resolution  AC Voltage    DC Voltage
    45 Hz to 65 Hz  45 Hz to 1 KHz       
    0 to 39.9V 0.01V
    0 to 399.9V 0.1V ±(2.5% +5) 0 to 600V 1V ±(1.5% + 5) ±(1.5% + 5)
    RESISTANCE:
    Range               Resolution Accuracy
    0 to 399.9 Ω 0.1Ω ±(1.0% + 10)
    0 to 3.999 K Ω1Ω ±(1.0% + 3)CONTINUITY CHECK:
    Range     Continuity Beeper
    400 Ω Approx. < 35 Ω
    ±(1.0% + 3)
    ±(1.0% + 3)
    ORDERING INFORMATION Part No.
    True RMS Clamp-On Meter 536
    Included with each Model 536 are:
    Clip-On Holster, Test Leads, Carrying Strap
    User’s Manual, 9V Battery (Installed)
    Certificate of Conformity and Lifetime Warranty
    SPECIFICATIONS
    (Unless otherwise indicated, specifications are for one year in ±(% of reading + number of digits) @ 23°C
    LIFETIME WARRANTY  PROGRAM
    Our equipment is guaranteed against defective material and
    workmanship (excluding batteries and test leads) for a period of
    one year. For a lifetime warranty: (1) Simply register the unit upon
    receipt by completing and returning the product’s Warranty
    Registration Card. (2) Once a year, send the unit to any Altek
    authorized distribution center for re-certification. Claims under
    warranty can be made by returning the equipment, prepaid, to any
    authorized Altek distributor. Altek will repair, re-calibrate or
    replace, free of charge, any unit found to be defective or out of
    calibration at any time between re-certification intervals. The
    liability of Altek is restricted to that given under our guarantee. No
    responsibility is accepted for damage, loss or other expense
    incurred through sale or use of our equipment. Under no condition
    shall Altek be held liable for any special, incidental or
    consequential damage.
    OTHER PRODUCTS
    Altek designs and manufactures fast, accurate instruments for
    measurement, generation and simulation of virtually every
    process control signal. Consult our factory directly or contact your
    local stocking representative to order precise, low cost Milliamp
    Calibrators, Voltage Sources, Thermocouple Sources, RTD
    Simulators, Frequency Calibrators, Pressure Pumps, Indicators
    and Calibrators as well as electrical test instruments. Altek also
    produces calibrators for custom ranges and unique applications.
    New models are frequently added to the Altek family to meet all of
    your critical calibration requirements. 
    						
    All Altek manuals Comments (0)

    Related Manuals for Altek 536 Clamp On Sales Sheet User Manual