DATA SHEET 530 • 4000 COUNT (33/4digits) DIGITAL DISPLAY • 50 SEGMENT ANALOG SCALE • BACKLIT DISPLAY • TEST VOLTAGES FROM 250 to 1000 VDC • AUTORANGING INSULATION RESISTANCE MEASUREMENT TO 4000M ΩON DIGITAL DISPLAY AND 10G Ω(10,000M Ω) ON ANALOG SCALE • AC VOLTAGE CHECK TO 600V • BATTERY POWERED AND AUTO OFF • LOCKING TEST BUTTON FOR DIELECTRIC ABSORPTION TESTING • RS-232 INTERFACE FOR RECORDING DATA • AUTOMATIC DISCHARGE OF ITEM UNDER TEST • DESIGNED TO IEC 61010-1 SAFETY STANDARDS GENERAL INFORMATION ALTEK AUTORANGING INSULATION TESTER MODEL 530 Testing Insulation Virtually everywhere you go, electric wire can be found. Motors, transformers, generators, cables, etc. all have wiring covered with some type of insulating material. A variety of problems can occur if the insulation is allowed to deteriorate. The most common causes of deterioration in insulation are caused by environmental and/or physical damage. Moisture and extremes in temperature, vibration, abrasions, cuts or other mechanical damage, dust, dirt, grease or oil, plus normal electrical stress all contribute. The best way to evaluate insulation quality is to take measurements at regularly scheduled intervals so trends can be monitored. Planned reconditioning of motors and equipment can then be accomplished without risk of serious injury or catastrophic failures in your manufacturing process. Autoranging Insulation Tester The Altek Model 530 is an autoranging insulation tester. Use the 530 as the standard tool for testing your insulation. The reliable, straightforward megohmmeter is simple to use and easy to read. The quality backlight illuminates the display, making it easy to read even in the dark. The 530 provides its rated test voltages into a 1mA load, so youre sure that the full voltage is applied to the tested device. The instrument also offers continuity testing, with a short circuit current of at least 200mA and an open circuit voltage of 12.8V for your safety. Data Logging If record keeping is important to you, use the RS-232 serial port and the provided software on a Windows based computer to record your measurements. The insulation tester will automatically power off after 30 minutes of inactivity to preserve battery life. The 530 can be used for routine preventive maintenance as well as acceptance testing, QA testing in manufacturing, and diagnostic testing. ALTEK INDUSTRIES CORP
SPECIFICATIONS Unless otherwise indicated, specifications are for 1 year in ±(% of reading + number of digits) @ 23°C General Display: 3.1 x 2.0 LCD. 3 3/4digits (4,000 counts) Digital readout with an analog bar indication. Backlighting available Measurement Range: 600VAC, 40Ω, 4000M Ω/250V, 4000M Ω/500V, 4000M Ω/1000V Sampling Rate: 2.5 times/second for digital reading 10 times/second for analog indication Auto Power Off: Approx. 30 minutes of inactivity Over Range Indicator: OL will be displayed Operating Temperature Range: 32°F to 104°F (0°C to 40°C) Storage Temperature Range: 14°F to 140°F (-10°C to 60°C) Operating Relative Humidity: 0% to 80% (noncondensing) Storage Relative Humidity: 0% to 70% (noncondensing) Altitude Range: Up to 6,500 feet Power Supply: 12VDC, (8 x 1.5V Size AA batteries) Power Consumption: Approx. 90mA (4000M Ω/1000V range) (output open circuit) Approx. 60mA (4000M Ω/500V range) (output open circuit) Approx. 45mA (4000M Ω/250V range) (output open circuit) Approx. 20mA (ACV and OHMS range) Safety Standards: Designed to IEC 61010-1 Overall Size: 7.5L x 5.5W x 3.0H (190mm x 140mm x 77mm) Weight: Approx. 2Lbs (900g), includes battery Specifications subject to change without notice © August 2000 Altek Industries Corp 100912-901 Rev A ADDITIONAL INFORMATION LIFETIME WARRANTY PROGRAM Our equipment is guaranteed against defective material and workmanship (excluding batteries and test leads) for a period of one year. For a lifetime warranty: (1) Simply register the unit upon receipt by completing and returning the products Warranty Registration Card. (2) Once a year, send the unit to any Altek authorized distribution center for factory re- certification. Claims under warranty can be made by returning the equipment prepaid to any authorized Altek distributor. Altek will repair, re- calibrate or replace free of charge any unit found to be defective or out of calibration at any time between re-certification intervals. The liability of Altek is restricted to that given under our guarantee. No responsibility is accepted for damage, loss or other expense incurred through sale or use of our equipment. Under no condition shall Altek be held liable for any special, incidental or consequential damage. OTHER PRODUCTS Altek designs and manufacturers fast, accurate instruments for measurement, generation and simulation of virtually every process control signal. Consult our factory directly or contact your local stocking representative to order precise, low cost Milliamp Calibrators, Voltage Sources, Thermocouple Sources, RTD Simulators, Frequency Calibrators and Pressure Pumps, Indicators & Calibrators, as well as electrical test instruments. Altek also produces calibrators for custom ranges and unique applications. New models are frequently added to the Altek family to meet all of your critical calibration requirements. ORDERING INFORMATION Part No. Autoranging Insulation Tester 530 Included with each Model 530 are: Instruction Manual 100912-900 Altek 530 Windows Software (Diskette) Serial Cable (Optical to Female DB-9) 8 x 1.5V Size AA Batteries Certificate of Conformity and Lifetime Warranty AVAILABLE FROM OHMS & Continuity Beeper Max. Open Max. ShortCircuit Circuit Overload Range Resolution Accuracy Voltage Current Protection 40 Ω 0.01Ω 1%+30 12.8V 280mA* 220Vrms * Minimum Value: 200mA Max. OpenCircuit Overload Range Resolution Beeper Active Voltage Protection Beeper 0.01 ΩResistance