    Have a look at the manual Alpha Tool.Com.HK Limited Grinder ECG125 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 67 Alpha Tool.Com.HK Limited manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							41
    Limited Warranty of Alpha® Ecogrinder in the USA and Canada ONLY!Alpha  Professional  Tools®  warrants  this  product  against  defects  in  material  and workmanship for a period of 180 days from the date of original retail purchase (proof of  purchase  required).  If Alpha  Professional Tools®  receives  notice  of  such  defects during the warranty period, our obligation assumed under this warranty is limited to the repair or replacement of parts, without charge. This warranty does not apply to tool accessories.
    For Warranty Claims:  Send complete tool with all your information and details of the problem to your nearest Alpha® Repair Center, transportation prepaid. Do not send tool accessories.
       WARRANTY
    SERVICES AND WARRANTY INFORMATION
       LOANER PROGRAM
    Loaner tools can be issued to temporarily replace a tool that is being r\
    eturned to Alpha® 
    for repair.  If more than one tool is being returned for repair, the number of loaner tools 
    provided will be based on availability.  
    If	a	loaner 	tool	 is	required,	 contact	Alpha® Tool Department at (800) 648-7229 to receive a 
    Loaner Tool Application.  A valid credit card number must be provided as a security deposit.  
    The credit card will only be charged if the loaner tool is not returned to Alpha® within 30 days.  
    An	authorized	 signature	is	required	 for	the	 credit	 card	being	 used.		 A	second	 signature	 is	
    required	as	an	agreement	of	the	overall	policy.									
     
       NEED MORE INFORMATION 
    For information on Alpha Professional Tools® complete product line, visit us on the web at 
    www.alpha-tools.com   
    						
    							42
    For more information concerning Alpha® tool repair service, please contact the 
    Alpha® regional repair centers listed below:
    COMPANY HEADQUARTERS:    Alpha Professional Tools® 
         103 Bauer Drive
         Oakland, NJ 07436
    Hours  of  Operation:        8:30 a.m. – 5:00 p.m. EST
    Telephone Number:       201-337-3343
    Toll-Free Number:      800-648-7229
    FACTORY SERVICE AND 
    TRAINING CENTER:     3625 W. Teco Ave., 
         Suite #5    
         Las Vegas, NV 89118
    Hours  of  Operation:       7:30 a.m. – 4:00 p.m. PST
    Telephone Number:   702-837-9515
    Toll-Free Number:   888-292-5742
      ALPHA® TOOL REPAIR SERVICE   
    						
    							43
    EC DECLARATION OF CONFORMITY
    Name of Manufacturer:  Alpha Professional Tools®
    Address of Manufacturer: 103 Bauer Drive
       Oakland, NJ 07436
       USA
    Herewith declares that:
    ELECTRIC	HAND	TOOL:	 	 “Ecogrinder”
       Make:    Alpha Professional Tools®
      Type:    ECG-125/ECG-225  
    -Does comply with the provisions of the Low Voltage Directive 73/23EEC amended by 
    93/68 EEC and Machinery Directive 98/37/EC.
    And furthermore declares that:
    -The following (parts/clauses of) harmonized standards have been appli\
    ed:  
    EN55014-1/ + A1: 2001, EN55014-2/ + A1: 2001, EN61000-3-2:2000, EN61000-3-
    3/+A1:2001.
    Year	of	affix	CE	Marking:	2007
    Oakland, New Jersey USA
          
    Nao Takahashi
    (President)   
    						
    							44
    Figure-42
    Figure-43
    Manual Height Adjustment Flange Assembly
    Manual Height Adjustment Flange
    Flange 
    NutAdjust
    Screw
    Lock
    NutAdjust
    Nut
    Bottom
    Pulley
     
    APPENDIX A
      MANUAL HEIGHT ADJUSTMENT FLANGE ASSEMBLY
    For those end-users wanting to run a different grinding wheel on their E\
    cogrinder, we make 
    a	manual	height	adjustment	flange	assembly.
     
    1.  Follow the steps to remove the grinding wheel.  Once the grinding wheel \
    is removed, 
    you can now start the installation and adjustment of the manual height adjustment 
    flange.
    2.  Install the adjustment screw, lock nut, and adjustment nut into the bottom pulley and 
    spindle shaft as shown below.
       
    						
    							45
     3.  Place the grinding wheel on top of the adjust screw and check the air gap between 
    the top of the grinding wheel and the brush assembly.  The grinding wheel should 
    be adjusted so there is a 1mm air gap between the ruler and the brush ri\
    ng.  Test by 
    turning	the	wheel	to	make	sure	the	ruler	is	floating	on	top	of	the	brush.
     
    4.	 If	 the	air	gap	 is	too	 large	 or	too	 small	 remove	 the	flange	 and	adjust	 screw.	 Turn	the	
    adjust nut clockwise to raise the height of the grinding wheel or counter clockwise 
    to lower. Go back to step three and check the air gap again.  Repeat until air g\
    ap is 
    correct.
     
    Note: You will need to check the grinding wheel height before each use.  As the diamond 
    segments	 on	the	 grinding	 wheel	wear	down,	 the	manual	 height	adjustment	 flange	
    will need to be adjusted to keep the diamond segments just above (1mm a\
    ir gap) 
    the top of the brush assembly.
    Figure-44
    Figure-45
    Setting the Air Gap on the Manual Height Adjustment Flange
    Adjusting the Manual Height Adjustment Flange
    Hold the Adjust 
    Screw and locking 
    Nut in place
    Turn Adjust Nut 
    to raise or lower 
    the height of the 
    grinding wheel
    Air Gap   
    						
    							46
    5.	 Once	the	correct	 air	gap	 is	set,	 remove	 the	manual	 height	adjustment	 flange	assembly. 	
    While holding the adjust screw and adjust nut in place, turn the locking nut towards 
    the adjust nut until they meet.
     
    6.	 Hand	 tighten	the	manual	 height	adjustment	 flange	assembly	 to	lock	 the	adjust	 nut	in	
    place on the adjust screw.
    7.	 With	 the	manual	 height	adjustment	 flange	adjusted	 correctly,	 you	can	reinstall	 with	
    the	grinding 	wheel 	and 	flange	 nut.		From 	this	 point, 	you 	can 	follow	 the	instructions 	for 	
    installing the grinding wheel.
     
    Figure-46
    Hold the Adjust 
    Screw and Adjust 
    Nut in place
    Turn the Locking 
    Nut until it meets 
    the Adjust Nut
    Adjust the Locking Nut   
    						
    							47
    Photocopy of product registration form will be accepted.
    PRODUCT REGISTRATION CARD
    Model No.                  Serial No.
    Company Name: ______________________________________________
    Name: ______________________________________________________
    Address: ____________________________________________________
    City: _______________________State: ________Zip: ________________
    Telephone: ___________________________________________________
    Purchase Date: _______________________________________________
    Dealer’s Name: _________________________________
    Note:  Serial & Model Number must be included for proper registration.
    (800) 648-7229
    Mail or Fax to:
    Alpha Professional Tools®
    103 Bauer Drive, Oakland, NJ 07436
    Fax: 800-286-0114
    Register online at: 
    www.alpha-tools.com/productregistration.aspx   
    						
    							Copyright © 2008 Alpha Professional Tools. All rights reserved. 
    103 Bauer Drive, Oakland, NJ 07436 • 800-648-7229 • Fax: 800-286-0114www.alpha-tools.com
    9/22/2010  
    						
    All Alpha Tool.Com.HK Limited manuals Comments (0)

    Related Manuals for Alpha Tool.Com.HK Limited Grinder ECG125 User Manual