49. Disable Permanent Passage Mode (This Function enabled through keypad only) 
50. Return Lock to Normal Passage 
Mode Schedule 
(This Function enabled through keypad only) (Locks will lock or unlock depending on the current schedule).  Use Function 50 to undo Functions 48 and/
or 49, and therefore return the lock to all pre-existing scheduled functions. 
•Function 48 allows passage through the door without the need for a User Code.  Re-Lock using Function 49. 
•Programmed Schedules will not...

Page 22

22 
; 5 5 : 
; 5 7 :
  57. Print Clock Settings, Software 
Version and Door Number
 
  
55. Print Audit Trail  
; 5 6 :
  56. Print User Code List  
; 5 8 :
 58. Upload/Download PC Data 
Hold the printer over the locks infrared sensor as shown in Figure 1 and Figure 2 above.  
Twenty (20) events will print at a time; press 1 for more events, or 9 to quit.  To abort 
printing, press any key for 3 seconds (three short beeps will sound). 
Hold the printer over the locks infrared sensor as shown in Figure 1...

Page 23

23 
60. Number of Attempts Before Lockout  
61. Set the Attempts Lockout Time 
Used with Function 61 
•
Number of attempts before lockout must be 1-9 attempts. 
•
The number of attempts is reduced by half every time the keypad is locked out without a 
successful code entry (default is 6 attempts).   
•The attempt count is reset each time a valid code is entered. 
Function 61 determines the length of time the keypad is locked-out after a series of 
unsuccessful attempts (default is 18 seconds).  Used with...

Page 24

24 
68. Delete All Relay Functions and System Options added 
by Function 67.  Also Privacy Time-Out Duration.
 ; 6 8      ;  [ _ _ _ ]  : 
                                                       (3-digits) 
Enter ;
 6
 8
      ;
 0
 0
 0
 :
 to delete all Relay Functions and System Options added by 
Function 67.  Note:  
Programming 000 does not affect existing Privacy Time-Out Duration settings, described below. 
 When using a DL4100 or DL4500, enter a number between 001-250 for Privacy Time-Out...

Page 25

25 
Scheduled Passage and Group 
Use the functions below to enable Passage Mode and enable/disable Groups at the time programmed. 
•For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday, 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, and 0 for all days of week. 
SCHEDULES 
74. Schedule Enable Group 1 ; 7 4      ; [ _ ]           ; [ _ _ _ _ ] : 
                                         (Day)                                (Time) 
75....

Page 26

26 
QUICK SCHEDULES 
84. Business Quick Schedule 
7AM-5PM, Monday - Friday (This Function enabled through keypad only) 
; 8 4      ; [ _ ] :  
(Group)  
; 8 5      ; [ _ ] :  
(Group)  85. Day Quick Schedule  
7AM-5PM, All days (This Function enabled through keypad only) 
; 8 6      ; [ _ ] :  
(Group)  86. Evening Quick Schedule 
3PM-1AM, All days (This Function enabled through keypad only) 
; 8 7      ; [ _ ] :  
(Group)  87. Night Quick Schedule 
11PM-9AM, All days (This Function enabled through...

Page 27

27 
To Disarm a Burglary Control Panel 
90. Relay Activation  
(Open Time Window)
 
; 9 0      ; [ _ ]           ; [ _ _ _ _ ] : 
                                          (Day)                                      (Time) 
Functions 90 and 91 allow you to set up a window of time where if any 
Group 1 User Code is entered within this window, 
the relay will be activated for 2 seconds.  This relay is for use with a Control Panel that has a key switch disarm option.  For 
additional information, see Group 1...

Page 28

28 
; 9 9      ; 0 0 0
 :
  99. Clear All Lock Programming (This Function enabled through keypad only) 
Clears all programming, and returns lock to factory default settings (Residency for 
DL4500 and Privacy for DL4100).  Audit Trail contents are maintained. 
 
Note: 
 See Function 68 on page 24 for clearing Residency and Privacy Features.  M 
CLEAR ALL PROGRAMMING 
94 - 98. Reserved 
92. Enable Group 4  
(Open Time Window) 
(This Function enabled through keypad only) 
; 9 2      ; [ _ ]           ; [ _...

Page 29

29 
Groups and Scheduled Group 1 Examples  
The following examples detail the more advanced features of the DL series locks.  Although all features and device functions can be programmed 
using the lock keypad, when programming becomes more complex you may find it easier to use DL-Windows software to program your Alarm Lock 
security lock.  For more information, contact your Alarm Lock security professional. 
 
Assign a User to Two Groups 
Create a User 101 (all Users 101-150 are members of Group 2 by...

Page 30

30 
Groups and Scheduled Group 1 Examples (contd.) 
 
Functions 90/91:  Use Function 90 and 91 (see page 27) to create a window of time where if any Group 1 User Code is entered within the 
programmed window, a relay 
will be activated for 2 seconds.  The relay can be configured to disarm a burglary control panel.  See page 28. 
 
1.    Enter Program Mode (if not in already). 
2.    Connect relay to a burglar control panel with switch input for disarming. 
3.    Using Function 2, create User 4 with a...