Home > Alarm Lock > Alarm Lock > Alarm Lock Panic Exit Devic 265 265L 715 Installation Operation Instructions User Manual

Alarm Lock Panic Exit Devic 265 265L 715 Installation Operation Instructions User Manual

Here you can view all the pages of manual Alarm Lock Panic Exit Devic 265 265L 715 Installation Operation Instructions User Manual. The Alarm Lock manuals for Alarm Lock are available online for free. You can easily download all the documents as PDF.

Page 1

1 
345 Bayview Avenue 
Amityville, New York 11701 
CALL TOLL FREE: 800-ALA-LOCK 
(800) 252-5625 
ELECTRONIC EXIT DOOR ALARMS 
PADDLE ARM MODEL 265/265L 
PUSH BAR MODEL 715 
INSTALLATION AND OPERATION INSTRUCTIONS 
GENERAL DESCRIPTION 
Models 265, 265L (long arm) and 715 are non-handed, 
delayed egress, electronic exit door locking systems. Arming 
is accomplished by actuating the deadbolt using a 1
1/8” rim 
cylinder (not included). When armed, depressing the paddle 
(Model 265) or push bar (Model 715)...

Page 2

2 
requires an optional Surface Wiring Kit, Model SWK715, for 
routing of wires from the Lock Assembly to the Control Box.  
Note: If mounting onto a hollow door, wiring may be routed 
inside the door. A 
3/8x36” straight drill will be required to drill 
through the door frame from the top and hinged-side edges 
and through internal reinforcements to allow snaking of wires. 
In this case, drill wire exit and entry holes and snake wires 
before mounting the Lock Assembly. 
 
Sufficient cable (10 feet) is...

Page 3

3 
washer from the Paddle Arm Hinge Bracket. Depress the 
Paddle Arm Hinge Bracket slightly and attach the Push 
Bar to the bracket using the #10-32 Phillips screw and 
lock washer just removed. Attach the End Cap to the 
Retaining Bracket using the #10-24x½” oval-head Phillips 
screw supplied. 
 
8.  Install the Keeper Assembly. Orient the Keeper 
Assembly against the door jamb so that the Cam Latch 
and the deadbolt on the lock are aligned with the 
respective holes in the Keeper Cover. Remove the...

Page 4

4 
together and Terminal 6 of all units must be connected 
together. Be sure to check that all doors unlock when the 
fire-panel relay opens. 
 
COMPLETING THE INSTALLATION 
1.  The Lock Assembly is factory wired to provide a 
continuous alarm when tripped until reset by disarming. 
For an automatic alarm shutdown after two minutes, 
remove the Shutdown Jumper (see Wiring Diagram). 
2.   Connect the battery clip to the 9-volt battery. 
3.   Replace the Lock Cover, being sure that the Cam Latch is 
first...

Page 5

5 
2.  When the lock is disarmed, pressing the bar or paddle will 
open the door instantly without sounding the alarm. Check 
that the lock relatches after 5 seconds. 
3.  Trip the fire-detection or other emergency device with the 
lock armed. Press the bar or paddle and check that the 
latch is released instantly and that the alarm sounds. The 
smoke detector is reset by disarming the lock. 
4. The unit is electrically failsafe. Should any wire open for 
any reason, the exit delay will be eliminated and...

Page 6

6 
SUBASSEMBLIES 
The following subassemblies are supplied complete and assembled only, comprising the reference numbers shown. 
Control Box PCB (not shown) ................................................. S5912 
Lever Subassembly (Ref. Nos. 111, 112, 113, 114) .............. S5910 
Deadbolt Subassembly (Ref. Nos. 7, 28, 29, 43) ................... S5907 Bolt Cover/Paddle Arm Subassembly (Ref. Nos. 2, 3, 11, 18, 19, 21, 
24, 27, 30, 31, 32, 39, 40, 44, 53, 54, 65, 115, 125, 126, 134, 
135)...

Page 7

7 
EXPLODED VIEW AND PARTS LIST, MODEL 715 
Ref. No. Description Part No. 
1 Keeper Cover P0248 
2 Retaining Ring, Truarc P1140 
3 Pivot Arm P5093 
6 Keeper Base P5642 
7 Roller, Deadbolt P1158 
8 Cam, Plastic P1159 
9 Ball Bearing P1160 
11 Spring, Return P1168 
13 Spring, Dropout Lever P5635 
14 Keeper Roller P5643 
15 Label, Push Bar P5023 
16 Hinge Bracket P5022 
17 Screw, 6-32x, Phillips Truss P1508 
18 Lock Washer, #6 P5244 
19 Screw, 6-32x PH Phillips P1520 
Ref. No. Description Part No. 
21 Push...

Page 8

8 
SUBASSEMBLIES 
The following subassemblies are supplied complete and assembled only, comprising the reference numbers shown. 
Control Box PCB (not shown) ........................................... S5912 
Lever Subassembly (Ref. Nos. 111, 112, 113, 114) .......... S5910 
Deadbolt Subassembly (Ref. Nos. 7, 28, 29, 43) ............... S5907 Bolt Cover Subassembly (Ref. Nos. 2, 3, 11, 16, 17, 18, 19, 30, 
31, 32, 44, 53, 54, 115, 125, 126, 134) ...................... S5908  
Alarm Lock Systems, Inc. 
345...