Page 1
1 345 Bayview Avenue Amityville, New York 11701 CALL TOLL FREE: 800-ALA-LOCK (800) 252-5625 ELECTRONIC EXIT DOOR ALARMS PADDLE ARM MODEL 265/265L PUSH BAR MODEL 715 INSTALLATION AND OPERATION INSTRUCTIONS GENERAL DESCRIPTION Models 265, 265L (long arm) and 715 are non-handed, delayed egress, electronic exit door locking systems. Arming is accomplished by actuating the deadbolt using a 1 1/8” rim cylinder (not included). When armed, depressing the paddle (Model 265) or push bar (Model 715)...
Page 2
2 requires an optional Surface Wiring Kit, Model SWK715, for routing of wires from the Lock Assembly to the Control Box. Note: If mounting onto a hollow door, wiring may be routed inside the door. A 3/8x36” straight drill will be required to drill through the door frame from the top and hinged-side edges and through internal reinforcements to allow snaking of wires. In this case, drill wire exit and entry holes and snake wires before mounting the Lock Assembly. Sufficient cable (10 feet) is...
Page 3
3 washer from the Paddle Arm Hinge Bracket. Depress the Paddle Arm Hinge Bracket slightly and attach the Push Bar to the bracket using the #10-32 Phillips screw and lock washer just removed. Attach the End Cap to the Retaining Bracket using the #10-24x½” oval-head Phillips screw supplied. 8. Install the Keeper Assembly. Orient the Keeper Assembly against the door jamb so that the Cam Latch and the deadbolt on the lock are aligned with the respective holes in the Keeper Cover. Remove the...
Page 4
4 together and Terminal 6 of all units must be connected together. Be sure to check that all doors unlock when the fire-panel relay opens. COMPLETING THE INSTALLATION 1. The Lock Assembly is factory wired to provide a continuous alarm when tripped until reset by disarming. For an automatic alarm shutdown after two minutes, remove the Shutdown Jumper (see Wiring Diagram). 2. Connect the battery clip to the 9-volt battery. 3. Replace the Lock Cover, being sure that the Cam Latch is first...
Page 5
5 2. When the lock is disarmed, pressing the bar or paddle will open the door instantly without sounding the alarm. Check that the lock relatches after 5 seconds. 3. Trip the fire-detection or other emergency device with the lock armed. Press the bar or paddle and check that the latch is released instantly and that the alarm sounds. The smoke detector is reset by disarming the lock. 4. The unit is electrically failsafe. Should any wire open for any reason, the exit delay will be eliminated and...
Page 6
6 SUBASSEMBLIES The following subassemblies are supplied complete and assembled only, comprising the reference numbers shown. Control Box PCB (not shown) ................................................. S5912 Lever Subassembly (Ref. Nos. 111, 112, 113, 114) .............. S5910 Deadbolt Subassembly (Ref. Nos. 7, 28, 29, 43) ................... S5907 Bolt Cover/Paddle Arm Subassembly (Ref. Nos. 2, 3, 11, 18, 19, 21, 24, 27, 30, 31, 32, 39, 40, 44, 53, 54, 65, 115, 125, 126, 134, 135)...
Page 7
7 EXPLODED VIEW AND PARTS LIST, MODEL 715 Ref. No. Description Part No. 1 Keeper Cover P0248 2 Retaining Ring, Truarc P1140 3 Pivot Arm P5093 6 Keeper Base P5642 7 Roller, Deadbolt P1158 8 Cam, Plastic P1159 9 Ball Bearing P1160 11 Spring, Return P1168 13 Spring, Dropout Lever P5635 14 Keeper Roller P5643 15 Label, Push Bar P5023 16 Hinge Bracket P5022 17 Screw, 6-32x, Phillips Truss P1508 18 Lock Washer, #6 P5244 19 Screw, 6-32x PH Phillips P1520 Ref. No. Description Part No. 21 Push...
Page 8
8 SUBASSEMBLIES The following subassemblies are supplied complete and assembled only, comprising the reference numbers shown. Control Box PCB (not shown) ........................................... S5912 Lever Subassembly (Ref. Nos. 111, 112, 113, 114) .......... S5910 Deadbolt Subassembly (Ref. Nos. 7, 28, 29, 43) ............... S5907 Bolt Cover Subassembly (Ref. Nos. 2, 3, 11, 16, 17, 18, 19, 30, 31, 32, 44, 53, 54, 115, 125, 126, 134) ...................... S5908 Alarm Lock Systems, Inc. 345...