    Have a look at the manual Alarm Lock KEYPAD A100 WIRING PROGRAMMING INSTRUCTIONS User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1 
    A-100 
    INDOOR STAINLESS STEEL KEYPAD  
    WIRING & PROGRAMMING INSTRUCTIONS 
    WI1495  7/06 
    GENERAL DESCRIPTION 
    The A-100 is a self-contained access control keypad de-
    signed for indoor basic access applications.  Its heavy 
    stainless steel faceplate is designed to mount on a standard 
    single-gang electrical box.  The A-100 operates up to three 
    outputs (two relays and 1 open-collector transistor) and can 
    be used to trigger a door strike, an electromagnetic door 
    lock, or any other relay-activated device.  Programming is 
    performed manually at the keypad, allowing up to 150 indi-
    vidual Users, each with their unique User Codes.  The A-
    100 Series includes the rugged sealed environment A-
    100WP (see WI1496) and the waterproof A-100IMWP (see 
    WI1497) mullion keypad with illuminated keys. 
     
    In a typical application, the A-100 will energize one or both 
    relays upon the keypad entry of a valid User Code.  Outputs 
    1 and 2 are two relays of the three contact Form C type, 
    and Output 3 is an open collector transistor (terminal la-
    beled OC) that switches on (closes with the ground ter-
    minal) when energized.  The length of time the outputs are 
    energized (their activation duration) can be programmed 
    to between 1 and 99 seconds.  A Request-to-Exit button will 
    momentarily short Output 1 by wiring terminals M and P1 
    using a normally-open momentary-close switch.   
     To program the keypad functions you must first perform the 
    initial startup procedure, then enter Program Mode by 
    pressing the Master Code at the keypad.  Once in Program 
    Mode, all system functions can be accessed and pro-
    grammed.  Exit Program Mode to put the keypad (with its 
    new programming) into use. 
    SPECIFICATIONS 
    •12 to 24VDC (polarized) or 12 to 24VAC voltage input  
    •Output 1:  5A/250VAC relay 
    •Output 2:  3A/125VAC relay 
    •Output 3:  250mA open collector  
    •Capacity of 150 User Codes of 3 to 6 digits 
    •Output activation duration programmable from 01-99 sec-
    onds (program 00 to select toggle mode) 
    •All programming stored in non-volatile EEPROM memory 
    •Orange LED Keypress feedback 
    •Output #1 relay activation duration programmable per user 
    code 
    •Tamper switch output terminals (S1 - S2) on PCB 
    •Sounder beeps can be activated or deactivated for user 
    code entries 
    •Operating Temperature:        -13°F to 131°F 
                                                         -25°C to +55°C 
    •Dimensions (WxHxD):   3 x 4
    3/8 x 7/8  
                                               7.6cm x 11.1cm x 2.2cm 
    •Operating Voltage:          12VDC to 28VDC 
                                                  10VAC to 26 VAC 
    •Maximum Current Draw: 
    12VDC:  13mA (Standby)     48mA (Active) 
    24VDC:  20mA (Standby)     58mA (Active) 
    12VAC:  30mA (Standby)    100mA (Active) 
    24VAC:  50mA (Standby)    121mA (Active) 
    A-100 Wiring Table 
    Terminal Markings Description 
    + + 12V or 24V AC/DC Input 
    – – Ground 
    M Request to Exit Input 
    P1 Request to Exit Input 
    OC Open Collector Output 
    NO Relay 1 Normally Open 
    C1 Relay 1 Common 
    NC Relay 1 Normally Closed  
    NO Relay 2 Normally Open 
    C2 Relay 2 Common  
    NC Relay 2 Normally Closed  
    S1 Tamper SW Output 
    S2 Tamper SW Output 
     
    NO C2 C1 NC NC NO M P1 OC + – 
    – Ground Request to Exit Input Request to Exit Input Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 
    S2 S1 
    Tamper SW Output 
    Tamper SW Output 
    A-100 
    Keypad 
    + 12V or 24V AC/DC Input 
    345 Bayview Avenue 
    Amityville, New York 11701 
    For Sales and Repairs 1-800-ALA-LOCK 
    For Technical Service 1-800-645-9440 
     
     Publicly traded on NASDAQ   Symbol: NSSC 
    © ALARM LOCK 2006  
    						
    							2 
    GETTING STARTED 
    First Time Startup--Self-Test 
    After you unpack the lock from its factory packaging, per-
    form the initial startup procedure (outlined below).  For 
    keypads already in use, this startup procedure can also be 
    used to erase all existing keypad programming and return 
    the keypad back to its original out of box factory default 
    condition.   
     
    1.   Install the jumper located on the back of the keypad. 
    2.   Apply power (12-24VDC polarized or 12-24VAC) to 
    the power input terminals. 
    •Orange LED blinks once 
    3.   Press 
    7890#123456*  
          (note that keys are silent when pressed). 
    •Red LED turns ON 
    •Orange LED turns ON 
    •Green LED turns ON 
    •Green LED turns OFF 
    •Each Output 1,2 & 3 activates for 1½ seconds 
    •Orange LED turns OFF 
    •Sounder beeps twice (memory resets and default 
    values enabled) 
    4.   Close the Request to Exit button (short terminals 
    M and P1). 
    •Red LED blinks 
    5.   Remove the jumper on the back of the keypad. 
    •Sounder beeps once 
    6.   Remove power to the power input terminals. 
    7.   Apply power to the power input terminals. 
    •Sounder beeps once 
    If the keypad encounters a problem while memory is re-
    setting at step 3, the sounder will beep continuously until 
    the jumper is removed and the procedure is repeated at 
    step 1.  The factory default values are detailed in the sec-
    tion below. 
     
    Default Values 
    No pre-configured user codes exist for new out of the 
    box keypads.  Other default values include: 
     
    User Code length                                                 4 digits 
    Maximum Delay Between Key Presses   10  seconds 
    Auto Exit Program Mode                          120 seconds 
    Factory Default Master Code                                1234 
    Output Activation Duration                          5 seconds 
    Sounder                                                          Always ON 
    First Key Press Activates Output 3                 Inactive 
     
    Enter Program Mode  
    The keypad software has only two modes--Normal 
    Mode and Program Mode.  When you want to make 
    changes to the keypad (enter new User Codes, etc.), you 
    enter Program Mode.  When you finish programming 
    and wish to put the keypad into use, you exit Program 
    Mode to enter Normal Mode.   
     
    •Enter Program Mode:  Press 55#1234*. 
     
    Enter Program Mode by pressing 
    55#, then press the 
    Master Code of the lock that was set at the factory (
    1234), followed by the * key (the orange LED 
    lights and the sounder beeps twice).   
     
    The factory Master Code (1234) is basically a se-
    cret passcode that allows you to enter Program Mode.  
    But since all keypads leave the factory with this same 
    Master Code, the factory Master Code is therefore not 
    very secret--and should be changed to your own personal 
    Master Code.  This way, only YOU can enter Program 
    Mode and make changes to the keypad programming.   
     
    Change Factory Master Code 
    Although the factory Master Code can be changed at any 
    time, for highest security, follow the procedure below: 
    Think of a new four-digit numeric Master Code and either 
    commit it to memory or write it here:  ___  ___  ___  ___.   
     
    Note:  Only numbers zero through 9 are valid digits for 
    either User Codes or the Master Code.  Keys 
    * or # 
    are not allowed.  In addition, the Master Code and all User 
    Codes must always be the same number of digits in 
    length (3-6 digits allowed).  Therefore, if you enter Pro-
    gram Mode and change this Code Length using Func-
    tion 30, you must then remain in Program Mode and 
    change the Master Code to conform to the new Code 
    Length.  At this point, however, we recommend you do 
    not change the Code Length unless you are an advanced 
    user. 
     
    1.  If not in already, enter Program Mode (press 
    55#1234*).   
    •Orange LED lights  - sounder beeps twice. 
    2.  Press 
    31#  
    •Green LED blinks once - sounder beeps once. 
    3.  Press new 4-digit Master Code and press 
    #.   
    •Green LED blinks once - sounder beeps once. 
    4.  Re-press new 4-digit Master Code and press 
    #*. 
    •Green LED lights / sounder beeps for 1 second indi-
    cating the Master Code was changed successfully.   
     
    The keypad remains in Program Mode while the orange 
    LED remains lit.  Note:  The keypad will automatically exit 
    Program Mode if no keys are pressed within 120 seconds 
    (2 minutes).   
     
    Adding User Codes 
    User Codes are 3-6 digit numbers the User presses into 
    the keypad keys to activate one or more Outputs.  The A-
    100 Series keypads can hold up to 150 User Codes in its 
    memory, thus allowing up to 150 people to possess their 
    own individual User Codes.  The keypad memory associ-
    ates each User Code with a 3-digit User Number listed 
    from 000 to 149.  Therefore, when adding new User 
    Codes, you must also select a 3-digit User Number be-
    tween 000 and 149 that will be associated (linked) with 
    the new User Code.  As with the Master Code, only num-
    bers zero through 9 are valid digits for User Codes (keys 
    * or # are not allowed) and each User Code must be 
    unique.   
     
    1.  If not in already, enter Program Mode. 
    •Orange LED lights  - sounder beeps twice.  
    						
    							3 
    2.   Press 32#  
    •Green LED blinks once - sounder beeps once. 
    3.   Press new 3-digit User Number and press 
    #.   
    •Green LED blinks once - sounder beeps once. 
    4.   Press new 4-digit User Code and press 
    #. 
    •Green LED blinks once - sounder beeps once. 
    5.   Re-press new 4-digit User Code and press 
    #*. 
    •Green LED lights / sounder beeps for 1 second indi-
    cating the User Code was added successfully.   
     
    Delete a User Code 
    1.   If not in already, enter Program Mode. 
    •Orange LED lights - sounder beeps twice. 
    2.   Press 
    34#  
    •Green LED blinks once - sounder beeps once. 
    3.   Press the 3-digit User Number associated with the 
    User Code you wish to delete and press 
    #*.   
    •Green LED lights / sounder beeps for 1 second indi-
    cating the User Code was deleted successfully.   
     
    Exit Program Mode 
    When you finish programming and wish to put the keypad 
    into use, you exit Program Mode to enter Normal Mode 
    as follows: 
     
    •Exit Program Mode:  Press *.  The orange LED turns off, the sounder beeps twice and 
    the red LED lights.  Note:  The keypad will automatically 
    exit Program Mode if no keys are pressed within 120 sec-
    onds (2 minutes).   
     
    Test the Keypad 
    Be sure to test all User Codes.  Keep in mind the follow-
    ing: 
    •Valid User Codes must be followed by the star (
    *) key 
    •Master Code and User Codes must all be the same 
    length 
    •By default, a valid User Code always activates Output 1 
    unless Output selection is changed 
     
     
    ALL PROGRAMMING FUNCTIONS  
    Your keypad is designed to support several options and 
    functions.  Using the keypad, you can select the features 
    you wish to activate, such as if the keypad sounder 
    should be disabled or enabled or you wish to change the 
    code length from 4 to 6 digits.. 
     Each function is organized below by its function number, 
    which is the first two digits pressed into the keypad when 
    programming.  To program, first enter Program Mode as 
    follows: 
     
    •Enter Program Mode:  Press 55# [Master Code] 
    *.  When you finish programming and wish to put the key-
    pad into use, exit Program Mode to enter Normal Mode 
    as follows: 
     
    •Exit Program Mode:  Press *. 
     
    Note:  The audible sounder and visual LED indicators 
    are displayed in the text below as follows: 
     [O2] = Orange LED lights and sounder beeps twice 
    [G1] = Green LED lights and sounder beeps once 
    [R2] = Red LED lights and sounder beeps twice 
     
    Note:  Every duration field is a two digit field.  Master code 
    is strictly reserved for entering Program Mode and cannot 
    be used to activate an Output.   
     
    21  Output 1 Activation Duration  
    Program time from 01 to 99 seconds.  Program 00 to 
    select latch mode where output remains activated by 
    the entry of a valid User Code (until deactivated by the 
    entry of a second valid User Code).  Note:  By default, a 
    valid User Code always activates Output 1 unless Out-
    put selection is changed. 
     
    Press:  21# [G1] ___ ___ #* [G1]. 
     
    22  Output 2 Activation Duration  
    Program time from 01 to 99 seconds.  Program 00 to 
    select latch mode where output remains activated by 
    the entry of a valid User Code (until deactivated by the 
    entry of a second valid User Code). 
     
    Press:  22# [G1] ___ ___ #* [G1]. 
     
    23  Output 3 Activation Duration  
    Program time from 01 to 99 seconds.  Program 00 to 
    select latch mode where output remains activated by 
    the entry of a valid User Code (until deactivated by the 
    entry of a second valid User Code). 
     
    Press:  23# [G1] ___ ___ #* [G1]. 
     
    30  Code Length  
    Changes the number of required digits in all new User 
    Codes and the existing Master Code.  3-6 digits are al-
    lowed, thus valid entries are 3, 4, 5 or 6.  The fac-
    tory default Code Length is 4. 
     WARNING:  When the Code Length is changed, all ex-
    isting User Codes and the Master Code become invalid.  
    Because the Master Code and all User Codes must al-
    ways be the same number of digits in length, if you 
    change the Code Length with Function 30 you MUST 
    remain in Program Mode and change the Master Code 
    to conform to the new programmed Code Length.   
     Press:  30# [G1] ___ #* [G1]. 
     
    31  Modify Master Code 
    Changes existing Master Code.  Note:  The Master 
    Code and all User Codes must always be the same 
    number of digits in length.  If changing the number of dig-
    its in the Master Code, you must first change the Code 
    Length via Function 30 (to accommodate the new num-
    ber of digits in the new Master Code) and--without exiting 
    Program Mode--change the Master Code via Function 
    31. 
     
    Press:  31# [G1] (new MC) # [G1] (new MC) #* 
    [G1]. 
      
    						
    							4 
    Be sure to either commit the Master Code to memory or 
    record it in a safe place.  If the Master Code is ever lost, 
    the keypad will need to be restarted using the First Time 
    Startup procedure described on page 2. 
     
    32  Add (or Edit) a User Code 
    Allows you to add a new or edit an existing User Code.  
    User Codes are 3-6 digit numbers the User presses into 
    the keypad keys to activate one or more Outputs.  The 
    A-100 Series keypads can hold up to 150 User Codes 
    in its memory, thus allowing up to 150 people to pos-
    sess their own individual User Codes.  The keypad 
    memory associates each User Code with a 3-digit User 
    Number listed from 000 to 149.  Therefore, when adding 
    new User Codes, you must also select a 3-digit User 
    Number between 000 and 149 that will be associated 
    (linked) with the new User Code.  As with the Master 
    Code, only numbers zero through 9 are valid digits for 
    User Codes (keys 
    * or # are not allowed) and each 
    User Code must be unique.  Programming requires en-
    tering the new User Code twice for confirmation, as fol-
    lows: 
     
    Press:  32# [G1] (User Number) # [G1] (User Code) 
    # [G1] (re-enter User Code) #* [G1]. 
     
    33  Add (or Edit) a User Code with Output 1 Duration  
    Same as Function 32 plus the ability of the individual 
    User Code to activate Output 1 for a specified duration 
    (from 01 to 99 seconds).  Program 00 to select latch 
    mode where output remains activated by the entry of a 
    valid User Code (until deactivated by the entry of a sec-
    ond valid User Code). 
     
    Press:  33# [G1] (time 01-99) # [G1] (User Number) 
    # [G1] (User Code) # [G1] (re-enter User Code) 
    #* [G1]. 
     
    34  Delete User Code 
    Overwrites specified User Number with vacant data, 
    thus erasing the User Code from memory. 
     
    Press:  34# [G1] (User Number) #* [G1]. 
     
    40  Reset Keypad 
    Erase all existing keypad programming and return the 
    keypad back to its original out of box factory default 
    condition 
     
    Press:  40# [G1] 12345# [G1]  
                  
    12345#* [G1].  
    52  Add (or Edit) a User Code with Output Activation 
    Same as Function 32 plus the ability of the individual 
    User Code to activate the specified Output(s).   
     
    Press:  52# [G1] (2-digits*) # [G1] (User Number) # 
    [G1] (User Code) 
    # [G1] (re-enter User Code) 
    #* [G1].  
    *Some examples of the 2-digits field: 
    •press 12 to activate Outputs 1 and 2 
    •press 23 to activate Outputs 2 and 3 
    •press 13 to activate Outputs 1 and 3 
    •press 02 to activate Output 2 only  
    •press 10 to activate Output 1 only ...etc. 
     
    Note:  If Function 70 (Output 3 Activates on First 
    Keypress) is enabled, Output 3 cannot be included in 
    the choices offered by Function 52. 
     
    Note:  The value in “Output 2 timer value” (from 01 to 99 
    seconds) is the duration of relay #2 activation when the 
    door bell button is momentarily pressed.  If the door bell 
    activation must follow the key press action, then “Output 
    2 timer value” should be 00. 
     
    60  Sounder Beeps 
    Activate sounder beeping or deactivate when pressing 
    User Codes only.   
     
    Always ON Press:  60# [G1] 1#* [G1]. 
    OFF for User Codes:  
    60# [G1] 0#* [G1].  Sounder factory default is Always ON. 
     
    70  Output 3 Activates on First Keypress 
    Enable Output 3 to activate upon any first keypress 
    when in Normal Mode (such as the first keypress 
    when entering a User Code).  Output 3 is a 250mA 
    open collector transistor output.  Function 70 can be 
    used for many purposes, such as to trigger a surveil-
    lance camera to record all activity at the keypad.  In ad-
    dition, Output 3 is silent, therefore Users will be unaware 
    when Output 3 is activated.  Function 70 can also be 
    used to deactivate this feature, as follows: 
     
    Activate Press:  70# [G1] 1#* [G1]. 
    Deactivate Press:  
    70# [G1] 0#* [G1].  
    Note:  If Function 70 is enabled, Output 3 cannot be 
    included in the choices offered by Function 52. 
    NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
    part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a 
    residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed 
    and used in accordance with the instructions, may cause harmful interference to radio communications.  However, 
    there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful 
    interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
    encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the re-
    ceiving antenna.  —Increase the separation between the equipment and receiver.  —Connect the equipment into an 
    outlet on a circuit different from that to which the receiver is connected.  —Consult the dealer or an experienced radio/ 
    TV technician for help.    
    						
    							5 
    Visual LED Indicators 
    LED In Normal Mode In Program Mode 
    Red Remains lit while waiting for a 
    keypress Confirms errors 
    Blinks when editing an existing User Number 
    Orange Flashes to confirm keypress Steady On to confirm in Program Mode.  
    Flashes to confirm keypress 
    Green Confirms activation of Outputs, mem-
    ory reset and Master Code reset Confirms valid data or empty User Number 
    Audible Sounder Indicators 
    Beep(s) In Normal Mode In Program Mode 
    1 short Unit power up and when a key is 
    pressed Valid data confirmation 
    1 long Relay activation following a valid 
    User Code Data recorded 
    4 short Data error Data Error 
    2 short Enter Program Mode Exit Program Mode 
    TWO KEYPADS CONTROL ONE DOOR 
    The below diagram displays how to control a single door with two keypads.  When you enter a valid code on Keypad 
    2, the magnetic lock unlocks directly.  When you enter a valid code on Keypad 1, the Request-to-Exit input of keypad 
    2 is triggered, unlocking the door.  Note:  Valid user codes must be programmed into both Keypads 1 and 2. 
    NO C2 C1 NC NC NO M P1 OC + – 
    – Ground Request to Exit Input Request to Exit Input Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 
    S2 S1 
    Tamper SW Output 
    Tamper SW Output 
    A-100 
    Keypad 
    + 12V or 24V AC/DC Input 
    NO C2 C1 NC NC NO M P1 OC + – 
    – Ground Request to Exit Input Request to Exit Input Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 
    S2 S1 
    Tamper SW Output 
    Tamper SW Output 
    A-100 
    Keypad 
    + 12V or 24V AC/DC Input 
    12-24 VDC /
    VAC Power 
    12-24 VDC /
    VAC Power Electromagnetic 
    Door Lock  
    (Fail Safe) 
    NO C2 C1 NC NC NO M P1 OC + – 
    – Ground Request to Exit Input Request to Exit Input Open Collector Output Normally Open Relay 1 Common Relay 1 Normally Closed Relay 1 Normally Open Relay 2 Common Relay 2 Normally Closed Relay 2 
    S2 S1 
    Tamper SW Output 
    Tamper SW Output 
    A-100 
    Keypad 
    + 12V or 24V AC/DC Input 
    Electromagnetic 
    Door Lock  
    (Fail Secure) 
    12-24 VDC /
    VAC Power 
    N/O  
    Request-
    to-Exit 
    Button 
    WIRING EXAMPLES 
    ONE KEYPAD CONTROLS A DOOR 
    The diagram at right displays basic wir-
    ing--how to control a single door with one 
    keypad.  When you enter a valid code on 
    Keypad 1, the magnetic lock unlocks di-
    rectly.  This wiring is Fail Secure which 
    means that if power is lost, the door will 
    remain locked.  
    						
    							6 
    PROGRAMMING FUNCTIONS--OVERVIEW 
    The audible sounder and visual LED indicators are displayed in the text below as follows:  [O2] = Orange LED lights and sounder beeps twice 
    [G1] = Green LED lights and sounder beeps once 
    [R2] = Red LED lights and sounder beeps twice 
    TIMER FUNCTIONS  
    FUNCTION 
    NUMBER DESCRIPTION PRESS THESE BUTTONS ON KEYPAD 
    21 Output 1 Activation Duration  Program time from 01 to 99 seconds.  Press:  21# [G1] ___ ___ #* [G1]. 
    22 Output 2 Activation Duration  Program time from 01 to 99 seconds.  Press:  22# [G1] ___ ___ #* [G1]. 
    23 Output 3 Activation Duration  Program time from 01 to 99 seconds.  Press:  23# [G1] ___ ___ #* [G1]. 
    USER FUNCTIONS  
    30 Code Length Press:  30# [G1] ___ #* [G1]. 
    31 Modify Master Code Press:  31# [G1] (new MC) # [G1] (new MC) #* [G1]. 
    32 Add (or Edit) a User Code Press:  32# [G1] (User Number) # [G1] (User Code) # [G1] (re-enter User 
    Code) 
    #* [G1]. 
    33 Add (or Edit) a User Code 
    with Output 1 Duration Press:  33# [G1] (time 01-99) # [G1] (User Number) # [G1] (User Code) # 
    [G1] (re-enter User Code) 
    #* [G1]. 
    34 Delete User Code Press:  34# [G1] (User Number) #* [G1]. 
    52 Add (or Edit) a User Code 
    with Output Activation Press:  52# [G1] (2-digits) # [G1] (User Number) # [G1] (User Code) # [G1] 
    (re-enter User Code) 
    #* [G1]. 
    FUNCTION 
    NUMBER DESCRIPTION PRESS THESE BUTTONS ON KEYPAD 
    SYSTEM FUNCTIONS  
    FUNCTION 
    NUMBER DESCRIPTION PRESS THESE BUTTONS ON KEYPAD 
    40 Reset Keypad Press:  40# [G1] 12345# [G1] 12345#* [G1]. 
    60 Sounder Beeps Always ON Press:  60# [G1] 1#* [G1]. 
    OFF for User Codes:  
    60# [G1] 0#* [G1]. 
    70 Output 3 Activates on 
    First Keypress Activate Press:  70# [G1] 1#* [G1]. 
    Deactivate Press:  
    70# [G1] 0#* [G1]. 
    FUNCTION 
    NUMBER DESCRIPTION PRESS THESE BUTTONS ON KEYPAD 
    55 Enter Program Mode Press 55# [Master Code] * 
    -- Exit Program Mode Press * 
    PROGRAM MODE  
    						
    							7 
    MOUNTING TEMPLATE 
    The A-100 is designed to be installed in a single-gang box.  The mounting screws are 3¼ apart. 
     
     
    3¼ 
     
      
    						
    							8 
    ALARM LOCK LIMITED WARRANTY 
    ALARM LOCK  SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in 
    materials and workmanship for 24 months following the date of manufacture. ALARM LOCK will, within said period, at 
    its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user. 
    This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly 
    installed, improperly used, abused, altered, damaged, subjected to acts of God, or on which any serial numbers have 
    been altered, defaced or removed. Seller will not be responsible for any dismantling or reinstallation charges. 
    THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION ON 
    THE FACE HEREOF. THERE IS NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A 
    WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITIONALLY, THIS WARRANTY IS IN LIEU OF 
    ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF ALARM LOCK. 
    Any action for breach of warranty, including but not limited to any implied warranty of merchantability, must be 
    brought within the six months following the end of the warranty period. IN NO CASE SHALL ALARM LOCK BE 
    LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY 
    OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLERS 
    OWN NEGLIGENCE OR FAULT. 
    In case of defect, contact the security professional who installed and maintains your security system. In order to 
    exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured 
    to ALARM LOCK. After repair or replacement, ALARM LOCK assumes the cost of returning products under warranty. 
    ALARM LOCK shall have no obligation under this warranty, or otherwise, if the product has been repaired by others, 
    improperly installed, improperly used, abused, altered, damaged, subjected to accident, nuisance, flood, fire or acts 
    of God, or on which any serial numbers have been altered, defaced or removed. ALARM LOCK will not be 
    responsible for any dismantling, reassembly or reinstallation charges. 
    This warranty contains the entire warranty. It is the sole warranty and any prior agreements or representations, 
    whether oral or written, are either merged herein or are expressly canceled. ALARM LOCK neither assumes, nor 
    authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other 
    warranty or liability concerning its products. 
    In no event shall ALARM LOCK be liable for an amount in excess of ALARM LOCKs original selling price of the 
    product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any 
    failure of the product. Sellers warranty, as hereinabove set forth, shall not be enlarged, diminished or affected by and 
    no obligation or liability shall arise or grow out of Sellers rendering of technical advice or service in connection with 
    Buyers order of the goods furnished hereunder. 
    ALARM LOCK RECOMMENDS THAT THE ENTIRE SYSTEM BE COMPLETELY TESTED WEEKLY. 
    Warning: Despite frequent testing, and due to, but not limited to, any or all of the following; criminal tampering, 
    electrical or communications disruption, it is possible for the system to fail to perform as expected. ALARM LOCK 
    does not represent that the product/system may not be compromised or circumvented; or that the product or system 
    will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; nor that the product or system 
    will in all cases provide adequate warning or protection. A properly installed and maintained alarm may only reduce 
    risk of burglary, robbery, fire or otherwise but it is not insurance or a guarantee that these events will not occur. 
    CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, 
    OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. Therefore, the installer 
    should in turn advise the consumer to take any and all precautions for his or her safety including, but not limited to, 
    fleeing the premises and allege police or fire department, in order to mitigate the possibilities of harm and/or damage. 
    ALARM LOCK is not an insurer of either the property or safety of the users family or employees, and limits its liability 
    for any loss or damage including incidental or consequential damages to ALARM LOCKs original selling price of the 
    product regardless of the cause of such loss or damage. 
    Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation 
    of incidental or consequential damages, or differentiate in their treatment of limitations of liability for ordinary or gross 
    negligence, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights 
    and you may also have other rights which vary from state to state.  
    						