Have a look at the manual Alarm Lock Door Alarms Lektrolok Models 103 104 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
1 LEKTROLOK--MODELS 103 & 104RA DEADBOLT ELECTRIC LOCKS INSTALLATION INSTRUCTIONS 345 Bayview Avenue Amityville, New York 11701 For Sales and Repairs 1-800-ALA-LOCK For Technical Service 1-800-645-9440 © ALARM LOCK 2003 WI1192 4/03 The LEKTROLOK Models 103 and 104RA Deadbolt Electric Locks are compact units designed to fit narrow stile doors. Both models come complete with keepers (deadbolt holes) which make it simple to install on all types of doors or windows includ- ing single, pairs, double acting or overhead, either in-swinging or out-swinging. When the lock is aligned with the keeper, the deadbolt projects into the keeper thus locking the door. The deadbolt is retracted (and the door unlocked) by means of a re- mote switch, a key switch, time programmer or other electrical contact which interrupts the power. Both models are ideally suited to programmed locking and unlocking of laundromats, lobby doors, or other unattended areas. Use of a lighted push button switch at the door (Alarm Lock Model 191) assures that people inside the building can exit after Iock-up time; the door will relock automatically after exit. May be wired with smoke detectors and/or fire alarm systems for automatic unlocking in a fire emergency. MODELS AVAILABLE Model 103 is a standard fail safe unit which projects the dead- bolt only while power is on. When the power is off, the dead- bolt retracts. Model 104RA (Reverse Action) unlike the stan- dard unit is fail secure and will project the deadbolt only when the power is off. When the power is on, the deadbolt re- tracts. LEKTROLOK--MODEL 103/104RA ELECTRIC DEADBOLT FLUSH KEEPER ANGLED KEEPER MORTISE KEEPER. INSTALLED FLUSH (INSIDE THE DOOR FRAME). FOR USE WITH WOOD DOOR FRAMES ONLY.
2 Note: The deadbolt will not project unless the magnet is opposite the reed switch. The template supplied serves the majority of installations. If your installation is different, always maintain a 1/8” gap between the face of the lock and the keeper. The lock should be mounted on the door frame (rather than the door) for ease of wiring. If in- stalling the lock with the plunger facing down, see special installation instructions on the next page. Before mounting the lock, provide for the electric wires to the lock. After the lock and keeper are installed, place the magnet onto the keeper slot which faces the reed switch in the lock as shown in figure 1. After the magnet is in place, affix the aluminum plate into the keeper recess. INSTALLATION INSTRUCTIONS SPECIFICATIONS DIMENSIONS: 1¾ W x 6¾ L (including keeper). Bolt diameter is 5/8 and projects 5/8. FINISH: Lock and keeper--painted aluminum. WEIGHT: 3 lbs., including keepers. POWER REQUIREMENTS: 600mA@24VAC or VDC (103). 12V version available a extra cost. LOCKING BOLT: Actuated by a continuous-duty solenoid. LOCK 24-VOLT AC/DC TRANSFORMER MODEL 221 NORMALLY OPEN SWITCH (ES) BLACK RED LOCK 24-VOLT AC/DC TRANSFORMER MODEL 221 NORMALLY CLOSED SWITCH(ES) BLACK BLACK MODEL 103 CONNECTIONS MODEL 104RA CONNECTIONS Follow the above schematics for one or more switches as required. Note: Model 103 requires switches to be installed in series. It is normally energized and normally runs hot to the touch. Model 104RA Reverse Action requires switches to be installed in parallel. FIGURE 1 KEEPER HOLE REED SWITCH The magnet inside the keeper hole assembly must be mounted op- posite the reed switch or the deadbolt will not work properly. MAGNET DEADBOLT MAGNET and REED SW ITCH must be mounted opposite each other
3 WHEN INSTALLING THE LOCK WITH PLUNGER FACING DOWN When installing the lock in a vertical position with the plunger facing down, we suggest replacing the colored spring (7 coils) with a stronger one (not colored, 5 coils) included in the box. To replace the spring, refer to the diagram below and replace it as follows: 1. Remove the lock cover. 2. Remove the screws holding the solenoid to the base. 3. Slide the solenoid out of the base. 4. Remove the colored spring (7 coils) and replace it with the spring (not colored, 5 coils) included in the box. 5. Slide the solenoid back into the base. 6. Fasten and tighten the screws holding the solenoid to the base. 7. Fasten the lock cover. Replacing the spring on Model 103/104 Lock
4 APPLICATION EXAMPLES OUTSWINGING VERTICAL INSTALLATION. DEADBOLT ON FRAME, ANGLED KEEPER ON DOOR INSWINGING HORIZONTAL INST ALL ATION NE AR FLOOR SEE ABOVE IMAGE INSTALL KEEPER BEFORE DEADBOLT. INSWINGING VERTICAL INSTALLATION. DEADBOLT ON FRAME FLUSH KEEPER ATTACHED TO TOP EDGE OF DOOR Mount lock on door frame (rather than the door) for ease of wiring. Examples are shown below: INSWINGING HORIZONTAL INSTALLATION. DEADBOLT ON FRAME (WITH SPACER) AND A FLUSH KEEPER SCREWED INTO DOOR (SEE BELOW IMAGE). SPACER MORTISE KEEPER. MAGNET IS MORTISED (EMBEDDED) INSIDE THE DOOR FRAME AND KEEPER IS INSTALLED FLUSH. FOR USE WITH WOOD DOOR FRAMES ONLY. (METAL FRAMES WILL DISSIPATE MAGNET STRENGTH).