Home > Alarm Lock > Alarm Lock > Alarm Lock Door Alarms Lektrolok Models 103 104 Installation Instructions

Alarm Lock Door Alarms Lektrolok Models 103 104 Installation Instructions

    Download as PDF Print this page Share this page

    Have a look at the manual Alarm Lock Door Alarms Lektrolok Models 103 104 Installation Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							1 
    LEKTROLOK--MODELS 103 & 104RA 
    DEADBOLT ELECTRIC LOCKS 
    INSTALLATION INSTRUCTIONS 
     345 Bayview Avenue 
    Amityville, New York 11701 
    For Sales and Repairs 1-800-ALA-LOCK 
    For Technical Service 1-800-645-9440 
    © ALARM LOCK 2003 WI1192  4/03 
    The LEKTROLOK Models 103 and 104RA Deadbolt Electric 
    Locks are compact units designed to fit narrow stile doors.  Both 
    models come complete with keepers (deadbolt holes) which 
    make it simple to install on all types of doors or windows includ-
    ing single, pairs, double acting or overhead, either in-swinging or 
    out-swinging.  When the lock is aligned with the keeper, the 
    deadbolt projects into the keeper thus locking the door.  The 
    deadbolt is retracted (and the door unlocked) by means of a re-
    mote switch, a key switch, time programmer or other electrical 
    contact which interrupts the power.  Both models are ideally 
    suited to programmed locking and unlocking of laundromats, 
    lobby doors, or other unattended areas.  Use of a lighted push 
    button switch at the door (Alarm Lock Model 191) assures that people inside the building can exit after Iock-up time; the door 
    will relock automatically after exit.  May be wired with smoke 
    detectors and/or fire alarm systems for automatic unlocking in a 
    fire emergency. 
     
    MODELS AVAILABLE 
    Model 103 is a standard fail safe unit which projects the dead-
    bolt only while power is on.  When the power is off, the dead-
    bolt retracts.  Model 104RA (Reverse Action) unlike the stan-
    dard unit is fail secure and will project the deadbolt only when 
    the power is off.  When the power is on, the deadbolt re-
    tracts. 
    LEKTROLOK--MODEL 103/104RA  
    ELECTRIC DEADBOLT 
    FLUSH KEEPER 
    ANGLED KEEPER 
    MORTISE KEEPER.  INSTALLED FLUSH 
    (INSIDE THE DOOR FRAME).  FOR USE 
    WITH WOOD DOOR FRAMES ONLY.  
    						
    							2 
    Note:  
    The deadbolt will not project unless the magnet is opposite the reed switch.  The template supplied 
    serves the majority of installations.  If your installation is different, always maintain a 1/8” gap between the face of the 
    lock and the keeper.  The lock should be mounted on the door frame (rather than the door) for ease of wiring.  If in-
    stalling the lock with the plunger facing down, see special installation instructions on the next page.   
     
    Before mounting the lock, provide for the electric wires to the lock.  After the lock and keeper are installed, place the 
    magnet onto the keeper slot which faces the reed switch in the lock as shown in figure 1.  After the magnet is in 
    place, affix the aluminum plate into the keeper recess.   
    INSTALLATION INSTRUCTIONS 
    SPECIFICATIONS  
    DIMENSIONS: 1¾ W x 6¾ L (including keeper).  Bolt diameter is 5/8 and projects 5/8. 
    FINISH: Lock and keeper--painted aluminum. 
    WEIGHT: 3 lbs., including keepers. 
    POWER REQUIREMENTS: 600mA@24VAC or VDC (103).  12V version available a extra cost. 
    LOCKING BOLT: Actuated by a continuous-duty solenoid. 
    LOCK 
     24-VOLT AC/DC 
    TRANSFORMER 
    MODEL 221 
    NORMALLY OPEN SWITCH
    (ES) 
    BLACK 
    RED 
    LOCK 
     24-VOLT AC/DC 
    TRANSFORMER 
    MODEL 221 
    NORMALLY CLOSED 
    SWITCH(ES) 
    BLACK 
    BLACK 
    MODEL 103 CONNECTIONS MODEL 104RA CONNECTIONS 
    Follow the above schematics for one or more switches as required.  Note:  Model 103 requires switches to be installed 
    in series.  It is normally energized and normally runs hot to the touch.  Model 104RA Reverse Action requires switches to 
    be installed in parallel. 
    FIGURE 1 
    KEEPER HOLE 
    REED SWITCH 
    The magnet inside the keeper hole assembly must be mounted op-
    posite the reed switch or the deadbolt will not work properly. 
    MAGNET 
    DEADBOLT 
    MAGNET and REED 
    SW ITCH must be 
    mounted opposite 
    each other  
    						
    							3 
    WHEN INSTALLING THE LOCK WITH PLUNGER FACING DOWN 
     
    When installing the lock in a vertical position with the plunger facing down, we suggest replacing the colored spring (7 
    coils) with a stronger one (not colored, 5 coils) included in the box.  To replace the spring, refer to the diagram below and 
    replace it as follows: 
     
    1.   Remove the lock cover. 
     
    2.   Remove the screws holding the solenoid to the base. 
     
    3.   Slide the solenoid out of the base. 
     
    4.   Remove the colored spring (7 coils) and replace it with the spring (not colored, 5 coils) included in the box. 
     
    5.   Slide the solenoid back into the base. 
     
    6.   Fasten and tighten the screws holding the solenoid to the base. 
     
    7.   Fasten the lock cover. 
    Replacing the spring on Model 103/104 Lock  
    						
    							4 
    APPLICATION EXAMPLES 
    OUTSWINGING VERTICAL INSTALLATION.  
    DEADBOLT ON FRAME,  
    ANGLED KEEPER ON DOOR 
    INSWINGING HORIZONTAL  
    INST ALL ATION NE AR FLOOR 
    SEE ABOVE IMAGE 
    INSTALL KEEPER BEFORE DEADBOLT. 
    INSWINGING VERTICAL INSTALLATION.  
    DEADBOLT ON FRAME 
    FLUSH KEEPER ATTACHED TO TOP 
    EDGE OF DOOR 
    Mount lock on door frame (rather than the door) for ease of wiring.  Examples are shown below: 
    INSWINGING HORIZONTAL INSTALLATION.   
    DEADBOLT ON FRAME (WITH SPACER) AND A FLUSH KEEPER 
    SCREWED INTO DOOR (SEE BELOW IMAGE).   
    SPACER  
    MORTISE KEEPER.  MAGNET IS MORTISED 
    (EMBEDDED) INSIDE THE DOOR FRAME AND 
    KEEPER IS INSTALLED FLUSH.  FOR USE WITH 
    WOOD DOOR FRAMES ONLY.  (METAL FRAMES 
    WILL DISSIPATE MAGNET STRENGTH).    
    						
    All Alarm Lock manuals Comments (0)

    Related Manuals for Alarm Lock Door Alarms Lektrolok Models 103 104 Installation Instructions