Page 11
11 WIRING See the Installation Manual for more information. POWER UP •When applying power to the lock for the first time, stop and follow the procedure outlined in Quick Start, First time Power Up on page 12. •When power is re-applied to a lock that was already operational, proceed as follows: 1. Disconnect battery pack connector. 2. With battery power disconnected, press and hold down ; for 10 seconds to insure...
Page 12
12 Quick Start First Time Start Up 1. Unpack the lock. 2. With the batteries disconnected, hold down the ; key for 10 seconds and release. 3. Connect the batteries and listen for 3 beeps. Within 5 seconds of hearing the 3 beeps, press and hold ; until beeping starts. This will clear the lock of all programmed data. Important: If you do not hear these 3 beeps, you must start over at step 2. 4. Listen for another series of beeps and LED flashes followed by 10 seconds of silence....
Page 13
13 Quick Start (cont’d) Enter User Codes 1. Enter Program Mode (if not in already). 2. Press ; 2 ; [ User Number] ; [new User Code] :. (For example, John Smith is designated as User 21. You want him to use the code of “232323” to unlock the door. Program the lock by pressing: ; 2 ; 21 ; 232323 :). 3. Repeat step 2 for each new user. Delete a User Code 1. Enter Program Mode (if not in already). 2. Press ; 2 ; [User Number] :. The lock will flash a green LED...
Page 14
14 Verifying Basic Keypad User Codes Test a valid User Code: •VALID CODE - The Green LED will flash momentarily and the sounder will beep a few times after a valid code is entered. •INVALID CODE - The RED LED will flash several times and the sounder will beep several times after an invalid code is entered. Use Function 2 to re-program the code. Testing the Codes Entered Notes
Page 15
15 Function 1 Change Master Code See page 16 Function 2 Add/Delete/Change User Codes See page 16 Function 3 User Disable (By User Number) See page 17 Function 4 User Enable (By User Number) See page 17 Function 5 User Enable with Timeout See page 17 Function 6 Enable Total User Lockout See page 17 Function 7 Disable Total User Lockout See page 17 Function 8 Reserved -- Function 9 Enable User 300 (Service Code) See page 17 Function 10 Erase All Users Except the Master Code See page 17...
Page 16
16 1. New Master Code (User Number 1) 2. Add/Delete/Change User Codes 2-2000 (Access through either side) ; 1 ; [ _ _ _ _ _ _ ] ; [ _ _ _ _ _ _ ] : (New Master Code) (Confirm New Master Code) ; 2 ; [ _ _ _ _ ] ; [ _ _ _ _ _ _ ] : (User Number) (User Code) •User Number must be between 2 and 2000. •User Codes added with this feature are enabled to pass from either side of the lock. To add User...
Page 17
17 USERS (Continued) ; 6 : 6. Enable Total User Lockout Mode (This Function enabled through keypad only) 7. Disable Total User Lockout Mode (This Function enabled through keypad only) ; 7 : User Lockout Mode Prevents all User Codes (Except User 1 Code) from operating the lock. Note: No other programming functions or schedules will re-enable Users. Users must be re-enabled with Function 7. Note: Does not change the User enable/disable status. Note: If the lock is currently in Passage Mode...
Page 18
18 ; 1 2 ; 0 0 0 : 12. Clear All Schedules and Timeout Functions Function 12 clears all programmed Schedules and all Timeout Functions. (To clear All Timeout Functions only, see Function 13 below). Function 12 will clear all of the following: All Schedule Functions 72 through 93, Timeout Functions 5, 25 through 34 and Function 47. Note: Function 12 also resets Passage Mode and any disabled Groups. After using Function 12, your Scheduled/Timeout features must be manually re-programmed....
Page 19
19 GROUPS Group Enable/Disable with Timeout (Enter Timeout, XXX Hours) (Functions 25-34 are enabled through the keypad only) •Hours must be between 1-999. Enter the functions below to Enable/Disable Groups for the amount of time entered in hours. NOTE: Only 4 Timeout Functions are allowed at any one time. An error beep will sound when attempting to program more than 4 Timeout Functions. Functions 25 - 34 will each override existing scheduled events. Therefore, Functions 25 - 34 are...
Page 20
20 ; 3 8 ; [ _ _ _ _ _ _ ] : (Date) 38. Set Date •Use Month Day Year format - MMDDYY - Single digit months and days are entered with a preceding zero. •Enter ONLY the last two digits of the year. For Example: March 8, 2002; Enter: ; 3 8 ; 0 3 0 8 0 2 : 3 39. Set Time ; 3 9 ; [ _ _ _ _ ] : (Time) •Time must be 4 digits •Use 24 Hour Format (add 12 hours to program PM time) For Example: To set time to 8:25PM; Enter: ; 3 9 ; 2 0 2 5 : For...