    Have a look at the manual Alarm Lock DL2700 Original Instructions OI209 17 users User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 84 Alarm Lock manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							UL LISTED: ELECTRICALLY-CONTROLLED SINGLE-POINT LOCK
    USER’S GUIDE TO DL2700-SERIES CODES AND USER’S GUIDE TO DL2700-SERIES CODES AND
    FEATURES FEATURES
    CONGRATULATIONS! Your new Alarm Lock Trilogy elec-
    tronic digital lock is a rugged entry lock of advanced design
    with several programmable features. Three security levels
    are provided: Master, Management, and User, the latter
    comprising 15 User Codes, including a 1-time entry Service
    Code. Take the time to read through this guide to familiarize
    yourself with the features and operation of the lock, and its
    quick and easy programming procedures.
    PRELIMINARY INFORMATION PRELIMINARY INFORMATION
    The DL2700 allows you to program
    ·1 Master Code (all functions including entry)
    ·1 Management Code (all functions including entry, but
    not Master Code, Management Code or Passage Func-
    tion)
    ·15 User Codes (3 banks of 5; entry only)
    ·1 Service Code (1-time entry)
    Important: Important: Before attempting to program any codes or
    functions, note the following:
    ·While the lever or knob may be rotated at any time, the
    latch will not be engaged to unlock the door unless a
    valid code has been entered.
    ·When a valid code is entered, the lock will unlock imme-
    diately and remain unlocked for about 5 seconds (or
    longer, if reprogrammed). When attempting to change a
    code, the respective program address and replacement
    code must be entered while unlocked. Therefore, it is
    recommended that all codes be prepared in advance for
    reference while programming (see Program Sheet), then
    be secured when finished.
    Audible Indications Audible Indications
    ·A beep will sound (a) when each key is pressed and (b)
    after a valid code is entered and (c) at the end of the
    unlock time (just before the unit relocks).
    ·If a wrong key is pressed during code entry, press the
    [AL] Button to clear the entry and start again.
    ·Two beeps will sound at the end of the antitamper
    lockout time.
    ·Five beeps will sound upon entry of an invalid code.
    ·Six beeps indicate acceptance of a programmed code.
    ·A 5-second tone (with red LED) when a key is pressed
    signifies a low-battery condition.
    LED Indications LED Indications
    LED indications are especially useful when the lock is
    used in noisy environments.
    Red LED
    ·The red LED will light momentarily whenever a key is
    pressed.
    ·If a wrong code is entered, the red LED will flash 5 times.
    ·If the batteries are weak, pressing any button will cause
    the red LED to come on, along with a steady sounderindication.
    Green LED
    ·The green LED will come on momentarily when a valid
    code has been entered.
    PROGRAMMING YOUR CODES PROGRAMMING YOUR CODES
    Master Code Master Code
    The Master Code can program any entry code or function.
    It may consist of 3 to 5 digits; the number of digits selected
    determines the number required for all other codes. The
    factory-programmed code is ‘‘1-2-3-4-5’’, but this code
    must be changed as follows to preserve security. For
    example, change the factory-programmed Master Code to
    ‘‘5-4-3-2-1’’. Note: Note: Changing the Master Code will erase all
    other codes.
    1. Enter existing Master Code:
    [1] [2] [3] [4] [5].
    A beep will sound and the lock will open.
    2. Within 5 seconds, enter Master Program Address:
    [AL] [1] [AL].
    3. Within 5 seconds, enter new Master Code:
    [5] [4] [3] [2] [1].
    4. (For Master Code only):
    Press [AL].
    5. Enter Master Code again to validate (only the Master
    Code must be validated):
    [5] [4] [3] [2] [1].
    Six beeps will sound and lock will relock after about five
    seconds.
    6. Test the new Master Code. Enter:
    [5] [4] [3] [2] [1].
    A beep will sound and the lock will open.
    Note: Note: If only one code is required, stop here and proceed
    to PROGRAMMING SPECIAL FUNCTIONS.
    Management Code Management Code
    The Management Code can program any user code (but
    not the Master or Management Code) or any programma-
    ble function except the Passage Function. It must contain
    the same number of digits as the Master Code. The follow-
    ing example will program a Management Code of ‘‘2-3-4-5-
    1’’ using the Master Code programmed in the example
    above. Note: Note: Changing the Management Code will not
    affect any other code.
    1. Enter the existing Master Code:
    [5] [4] [3] [2] [1].
    A beep will sound and the lock will open.
    2. Within 5 seconds, enter the Management Program
    Address:
    [AL] [2] [AL].
    3. Enter the Management Code:
    [2] [3] [4] [5] [1].
    Six beeps will sound and lock will relock after about five
    seconds.
    4. Test the Management Code. Enter:
    [2] [3] [4] [5] [1].
    A beep will sound and the lock will open.
    Note: Note: If only two codes are required, stop here and
    proceed to PROGRAMMING SPECIAL FUNCTIONS.
    User Codes  User Codes (Provide entry only)
    Up to 15 User Codes are available in three banks, each
    containing five users. User Codes are programmed by
    either a Master Code or a Management Code and the
    respective User Program Address shown below. Users may
    be ‘‘locked out’’ either individually or by bank, therefore
    when assigning codes, consider which users or groups will DL2700-SERIES DL2700-SERIES
    DIGITAL LOCKS DIGITAL LOCKS
    Programming Instructions Programming Instructions
    OI2094/96 
    						
    							be denied access on a regular basis to simplify the lockout
    procedure.
    User Codes must consist of the same number of digits as
    the Master Code. To program any User Code:
    1. Enter the Master Code or Management Code. A beep
    will sound and the lock will unlock.
    2. From Table 1, enter the Program Address for the
    selected user.
    3. Enter the User Code; six beeps will sound.
    4. Test the User Code.
    Note: Note: If several User Codes will be programmed at one
    time, it is not necessary to re-enter the Master or Manage-
    ment Code for each, so long as the lock is not allowed to
    relock. Therefore, after the six beeps sound (step 3, above)
    repeat steps 2 and 3 as necessary, then test all codes when
    done.
    Service Code Service Code
    The Service Code is a one-time User Code for cleaning
    crews, servicers, etc., that erases itself immediately after
    use. It is programmed as any User Code, with the Program
    Address AL-3-AL. If programmed, the Service Code re-
    places User Code 15 (Bank 3, User 5).
    PROGRAMMING SPECIAL FUNCTIONS PROGRAMMING SPECIAL FUNCTIONS
    Lockouts Lockouts
    Any single user, any bank of users, or all users may be
    prevented from entry.
    User Lockout. User Lockout. To temporarily disable any single user’s
    entry code,
    1. Enter the Master Code or Management Code.
    2. From Table 1, enter the user’s Program Address.
    3. Wait for the lock to relock.
    To re-enable the code, repeat the procedure.
    Group Lockout. Group Lockout. To temporarily disable all user entry
    codes of one or more banks,
    1. Enter the Master Code or Management Code.
    2. From Table 2, enter the Bank Disable Address(es).3. Wait for the lock to relock.
    To re-enable the code(s), repeat the procedure, replacing
    the Disable Address in Step 2 with the Enable Address.
    Note: Note: Re-enabling a group lockout does not re-enable a
    single-user lockout of that group (see User Lockout).
    Unlock Time Unlock Time
    This is the amount of time that the lock stays open after
    a valid code is entered. The factory-programmed time is 5
    seconds, however this time may be increased to up to 20
    seconds as follows.
    1. Enter the Master Code or Management Code.
    2. Enter Address [AL] [4] [5] [AL].
    3. From Table 3, enter the desired unlock time.
    Note: Note: To conserve battery power, keep unlock time as
    short as possible.
    Passage Passage
    Programming the Passage Function will maintain the
    DL2700 unlocked (no code required for entry) until repro-
    grammed. To set the Passage Function, enter the Master
    Code, then Address [AL] [4] [AL]. To relock, enter the
    Master Code, then Address [AL] [5] [AL].
    OTHER IMPORTANT INFORMATION OTHER IMPORTANT INFORMATION
    Antitamper Protection Antitamper Protection
    If three invalid codes are entered in succession, the unit
    will shut down for approximately 20 seconds to prevent
    code tampering. Two short beeps will sound when the lock
    has been reactivated.
    Battery Replacement Battery Replacement
    A 5-second dual tone (4 seconds high; 1 second low)
    when any key is pressed indicates that the batteries are
    weak. The DL2700 uses 5 AA-size1.5-volt alkaline batteries.
    The lock will function with weak batteries, however be sure
    to replace the batteries as soon as possible.
    Remove the screw at the bottom of the interior lock
    housing and remove the cover. Replace all 5 batteries
    quickly ---- within about 2 minutes ---- to avoid losing the
    memorized codes. Do not press any buttons while replac-
    ing the batteries! Replace the battery cover, then test the
    lock. Note: Note: To immediately erase all codes, remove the
    batteries and press any button.
    Should battery power fail and all codes be erased, open
    the door using the key and replace the batteries. Repro-
    gram all codes starting with the original factory Master
    Code (1-2-3-4-5).
    Remote Release Remote Release
    Provisions for unlocking the DL2700 from a remote loca-
    tion, overriding all codes, using an external momentary-
    contact switch.BANK BANKDISABLE ADDRESS DISABLE ADDRESSENABLE ADDRESS ENABLE ADDRESS
    1AL-5-1-ALAL-4-1-AL
    2AL-5-2-ALAL-4-2-AL
    3AL-5-3-ALAL-4-3-AL
    1--3AL-5-5-ALAL-4-4-AL
    Table 2. Bank Disable and Enable Addresses. Table 2. Bank Disable and Enable Addresses.ENTRY ENTRYTIME TIME
    15 SEC.
    210 SEC.
    315 SEC.
    420 SEC.
    Table 3. Unlock Times (times approximate). Table 3. Unlock Times (times approximate).BANK 1 BANK 1PROGRAM PROGRAM
    ADDRESS ADDRESSBANK 2 BANK 2PROGRAM PROGRAM
    ADDRESS ADDRESSBANK 3 BANK 3PROGRAM PROGRAM
    ADDRESS ADDRESS
    User 1AL-1-1-ALUser 1AL-2-1-ALUser 1AL-3-1-AL
    User 2AL-1-2-ALUser 2AL-2-2-ALUser 2AL-3-2-AL
    User 3AL-1-3-ALUser 3AL-2-3-ALUser 3AL-3-3-AL
    User 4AL-1-4-ALUser 4AL-2-4-ALUser 4AL-3-4-AL
    User 5AL-1-5-ALUser 5AL-2-5-ALUser 5*AL-3-5-AL
    *May be programmed as Service Code (AL-3-AL). See Service Code Service Code.
    Table 1. User Program Addresses. Table 1. User Program Addresses. 
    						
    							PROGRAM WORKSHEET: CODES PROGRAM WORKSHEET: CODES
    Instructions: Instructions: The Factory Master Code (1-2-3-4-5) may not be used for programming; it must first be reprogrammed as a new Master Code
    to enable its programming capabilities. Fill in codes in spaces provided prior to programming. All other codes must have the same number of
    digits as the new Master Code (3 to 5 digits). To load desired code, first enter Master or Management Code (except where indicated) and
    Program Address before unit relocks, then enter the code.
    1. MASTER CODE. 1. MASTER CODE. Must be programmed. Enter existing Master Code, then Program Address before unit relocks. Enter new Master Code,
    then press [AL]. Verify as shown.
    Press: 1   1       2   2       3   3       4   4     5   5              (beep) [AL] [1] [AL] [AL] [1] [AL]__ __ __ __ __ __ __ __ __ __ Press [AL] [AL] (for Master Code only)
    (Factory Master Code)(Program Address)(Master Code)
    Verify (enter Master Code again):__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    2. MANAGEMENT CODE. 2. MANAGEMENT CODE. Enter Master Code, then Program Address before unit relocks. Enter Management Code.
    Press:__  __  __  __  __ __  __  __  __  __       (beep)[AL] [2] [AL] [AL] [2] [AL]__ __ __ __ __  __ __ __ __ __ (6 beeps = OK)
     (Master Code)(Program Address)(Management Code)
    3. USER 1 CODE. 3. USER 1 CODE. Enter Master or Management Code, then Program Address before unit relocks. Enter User 1 Code.
    Press:__  __  __  __  __    __  __  __  __  __       (beep)[AL] [1] [1] [AL] [AL] [1] [1] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
                  (Master or Management Code)(Program Address)(User 1 Code)
    4. USER 2 CODE. 4. USER 2 CODE. [AL] [1] [2] [AL] [AL] [1] [2] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    5. USER 3 CODE. 5. USER 3 CODE. [AL] [1] [3] [AL] [AL] [1] [3] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    6. USER 4 CODE. 6. USER 4 CODE. [AL] [1] [4] [AL] [AL] [1] [4] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    7. USER 5 CODE. 7. USER 5 CODE. [AL] [1] [5] [AL] [AL] [1] [5] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    8. USER 6 CODE. 8. USER 6 CODE. [AL] [2] [1] [AL] [AL] [2] [1] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    9. USER 7 CODE. 9. USER 7 CODE. [AL] [2] [2] [AL] [AL] [2] [2] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    10. USER 8 CODE. 10. USER 8 CODE.[AL] [2] [3] [AL] [AL] [2] [3] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    11. USER 9 CODE. 11. USER 9 CODE.[AL] [2] [4] [AL] [AL] [2] [4] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    12. USER 10 CODE. 12. USER 10 CODE.[AL] [2] [5] [AL] [AL] [2] [5] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    13. USER 11 CODE. 13. USER 11 CODE.[AL] [3] [1] [AL] [AL] [3] [1] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    14. USER 12 CODE. 14. USER 12 CODE. [AL] [3] [2] [AL] [AL] [3] [2] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    15. USER 13 CODE. 15. USER 13 CODE. [AL] [3] [3] [AL] [AL] [3] [3] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    16. USER 14 CODE. 16. USER 14 CODE. [AL] [3] [4] [AL] [AL] [3] [4] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    17. USER 15 CODE*. 17. USER 15 CODE*. [AL] [3] [5] [AL] [AL] [3] [5] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    18. SERVICE CODE*. 18. SERVICE CODE*. [AL] [3] [AL] [AL] [3] [AL]__ __ __ __ __ __ __ __ __ __(6 beeps = OK)
    Note: Note: User Code provides entry only. To disable any user, enter Master or Management Code, respective Program Address, but no User
    Code. Allow unit to relock.
    * *User 15’s code may be used as a Service Code allowing one-time entry only.PROGRAM WORKSHEET: FUNCTIONS PROGRAM WORKSHEET: FUNCTIONS
    Instructions: Instructions: To program desired function, (1) enter Master Code or Management Code (except where indicated); (2) enter respective Program
    Address before unit relocks; (3) see notes, if any.
    1. RE-ENABLE BANK 1 1. RE-ENABLE BANK 1
    Press:__  __  __  __  __    __  __  __  __  __       (beep)[AL] [4] [1] [AL] [AL] [4] [1] [AL]
    (Master or Management Code)(Program Address)
    2. RE-ENABLE BANK 2 2. RE-ENABLE BANK 2[AL] [4] [2] [AL] [AL] [4] [2] [AL]
    3. RE-ENABLE BANK 3 3. RE-ENABLE BANK 3[AL] [4] [3] [AL] [AL] [4] [3] [AL]
    4. RE-ENABLE BANKS 1 4. RE-ENABLE BANKS 1-- --3 3[AL] [4] [4] [AL] [AL] [4] [4] [AL]
    5. UNLOCK TIME 5. UNLOCK TIME[AL] [4] [5] [AL] [AL] [4] [5] [AL]Note: Note: Press ‘‘1’’ for 5 sec.; ‘‘2’’ for 10 sec.‘‘3’’ for 15 sec.; ‘‘4’’ for 20 sec.
    6. ENABLE PASSAGE 6. ENABLE PASSAGE[AL] [4] [AL] [AL] [4] [AL]Note: Note: Code not required for entry. (Program using Master Code only.)
    7. DISABLE PASSAGE 7. DISABLE PASSAGE[AL] [5] [AL] [AL] [5] [AL]Note: Note: Code required for entry. (Program using Master Code only.)
    8. DISABLE BANK 1 8. DISABLE BANK 1[AL] [5] [1] [AL] [AL] [5] [1] [AL]
    9. DISABLE BANK 2 9. DISABLE BANK 2[AL] [5] [2] [AL] [AL] [5] [2] [AL]
    10. DISABLE BANK 3 10. DISABLE BANK 3[AL] [5] [3] [AL] [AL] [5] [3] [AL]
    11. DISABLE BANKS 1 11. DISABLE BANKS 1-- --3 3[AL] [5] [5] [AL] [AL] [5] [5] [AL]Note: Note: Total user lockout 
    						
    							USER USERDESCRIPTION DESCRIPTIONUSER’S NAME USER’S NAMECODE CODE
    ----MASTER
    ----MANAGEMENT
    ----SERVICE
    1BANK 1, USER 1
    2BANK 1, USER 2
    3BANK 1, USER 3
    4BANK 1, USER 4
    5BANK 1, USER 5
    6BANK 2, USER 1
    7BANK 2, USER 2
    8BANK 2, USER 3
    9BANK 2, USER 4
    10BANK 2, USER 5
    11BANK 3, USER 1
    12BANK 3, USER 2
    13BANK 3, USER 3
    14BANK 3, USER 4
    15BANK 3, USER 5USER CODE RECORD LOG USER CODE RECORD LOGAlarm Lock Systems Alarm Lock Systems
    345 Bayview Avenue 345 Bayview Avenue
    Amityville, New York 11701 Amityville, New York 11701 
    						
    All Alarm Lock manuals Comments (0)

    Related Manuals for Alarm Lock DL2700 Original Instructions OI209 17 users User Manual