Groups and Scheduled Group 1 Examples  
The following examples detail the more advanced features of the DK series locks.  Although all features and device functions can be programmed 
using the lock keypad, when programming becomes more complex you may find it easier to use DL-Windows software to program your Alarm Lock 
security lock.  For more information, contact your Alarm Lock security professional. 
 
Assign a User to Two Groups 
Create a User 101 (all Users 101-150 are members of Group 2 by...

Page 32

32 
Groups and Scheduled Group 1 Examples (contd.) 
Functions 90/91:  Use Function 90 and 91 (see page 29) to create a window of time where if any Group 1 User Code is entered within the 
programmed window, a relay will be activated for 2 seconds.  The relay can be configured to disarm a burglary control panel.  See page 29. 
 
1.    Enter Program Mode (if not in already). 
2.    Connect relay to a burglar control panel with switch input for disarming. 
3.    Using Function 2, create User 4 with a User...

Page 33

33 
Function Number(s) Function Name Programming  
43/44 Clock Adjust    
52/53/54 Pass Time          (3 sec) †     10 sec †    15 sec †  
60 Set Lockout Attempts   
61 Set Lockout Time     
64/65 Remote Input Momentary          (Enable) †    Disable †   
66 Ambush Code   
67 Add Relay/System Features 
 
  
 
 
 
 
69/70 Enter Key Enable †    (Disable) †   
  
+/-    0-55  
 (0) (0) Seconds 
 1-9 Attempts 
(6)  
  1-60 seconds 
(1) (8)  
  00-99 
(9) (9) Ambush Code 
Default Values are shown in...

Page 34

34 
User Number 
(1-2000) User Code  
(3-6 digits)  User Name 
       1 2 3 4  
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
            
Group  
Association 
  
For a complete list of user...

Page 35

35 
 Day(s)  
 
   
 
 
Function Number Up to 500 scheduled functions can be programmed (Up to 
only 150 using AL-DTM2).  For Day Enter : 
1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday 
5 = Thursday, 6 = Friday, 7 = Saturday, 8 = Monday through 
Friday, 9 = Saturday and Sunday, 0 = All days of the week 
Enter time of day in 24-hour format (00:00- 23:59)  
 
Time  
 
Function Name 
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :  
  :...

Page 36

36 
ACCESS = Entry into a restricted area. 
 
AMBUSH = A special Code entered at the keypad when the User is 
forced to unlock a device.  The device unlocks but sends a silent 
alarm with no indication at the keypad.  Can be used to trip a re-
lay, to alert security, or trip a silent alarm on a Burglary Control 
Panel. 
 
AUDIT TR AIL = A date/time stamped log of previous lock events. 
 
BURGLARY CONTROL PANEL = Provides local alarm and remote 
communication to request security for burglary/break-in....

Page 37

37 
 
•GROUP 1 ENABLES GROUP 4 USERS = A Group 1 USER CODE 
entry during a predefined schedule will allow access to Group 4 
Users. 
 
•GROUP 1 PUTS UNIT IN PASSAGE = A Group 1 USER CODE 
entry during a pre-defined schedule will unlock unit. 
 
INSTALLER = See.... CODE, INSTALLER CODE. 
 
KEYPAD = 10-numeric keys, : and special ; key. 
 
•KEYPAD LOCKOUT = Keypad is programmed to lockout Users, for 
a specified period of time, when a specified number of invalid User 
Codes are entered. 
 
•KEYPAD...

Page 38

38 
NOTES  

Page 39

39 
NOTES  

Page 40

40 
ALARM LOCK  SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in materials 
and workmanship for 24 months following the date of manufacture. ALARM LOCK will, within said period, at its option, 
repair or replace any product failing to operate correctly without charge to the original purchaser or user. 
This warranty shall not apply to any equipment, or any part thereof, which has been repaired by others, improperly 
installed, improperly used, abused, altered,...