Have a look at the manual AirComm Corporation Bell 429 Heating System 429H201M1 Rev3 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 74 AirComm Corporation manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
HEATER SERVICE MANUAL 429H-201M-1 Revision 2 Page 7-1 CHAPTER 7 TROUBLESHOOTING 1. SYSTEM TROUBLESHOOTING Prior to troubleshooting a defective system, it is advisable to conduct a visual inspection for general condition, and obvious signs of damage or failure. The following matrix lists the easiest checks, and the most likely problems. Problem Probable Cause Solution No Heat Bleed air shutoff valve not open Operate heater switch to ON position No Heat Heater System Control Valve in the off position Operate the heater system control valve to the ON position No Heat Shutoff valve failure Replace shutoff valve No Heat HTR Circuit breaker tripped Reset breaker No Heat. Heater OVER TEMP light illuminated Malfunction of Temp Sensor Switch Check switches – all switches should be electrically open (See figures 3.10 and 3.12) No Heat. Heater OVER TEMP light illuminated Air blockage of heater inlet or outlets Remove blockage No Heat. Heater OVER TEMP light illuminated Bleed air line fitting loose causing an over temperature condition Check all lines and fittings for security HEATER DUCT HOT light illuminated. Thermal Snap Switch too close to duct assembly Inspect snap switches to ensure a minimum 0.8 inch clearance between the snap switch and the duct.
![](/img/blank.gif)
HEATER SERVICE MANUAL 429H-201M-1 Revision 1 Page A-1 APPENDIX A Weight and Balance Information Weight breakdown – Bell 429 Provisions: Item Drawing Number Wt. (lbs) X-Arm (in) Y-Arm (in) X-M (in-lb) Y-M (in-lb) Misc Heater Provisions Instl 429H-514-1 2.29 163.4 -1.4 373 -3 Plumbing Provisions, Cabin Roof to Control Valve Instl 429H-534-1 7.23 157.5 -19.0 1139 -137 Plumbing Provisions, Control Valve to Ejectors Instl (Tubes) 429H-544-1 5.84 154.0 0.4 899 2 Plumbing Provisions, Control Valve to Ejectors Instl (Fittings) 429H-544-1 1.17 151.6 0.2 177 0 Electrical Provisions Instl 429H-814-1 0.11 222.0 11.0 23 1 Total (English Units) 429H-201 16.63 157.1 -8.8 2612 -137 Total (Metric Units) 429H-201 7.54 3989.7 -223.9 30095 -1577 * Negative value indicates left of center Weight breakdown – Bell 429 Components