Page 1

HEATER SERVICE MANUAL 429H-201M-1 
Revision 3    29 December 2011   
 
 
 
 
 
 
 
 
 
AIR COMM CORPORATION 
3330 AIRPORT ROAD 
BOULDER, CO. 80301 
Phone: (303) 440-4075 
Fax: (303) 440-6355 
[email protected] 
 
 
 
 
 
INSTRUCTIONS FOR CONTINUED AIRWORTHINESS 
BELL HELICOPTER 429 
HEATER SYSTEM 
 
 
 
 
 
 
 
 
 
 
           
   

Page 2

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page i        
 
 
 
 
REVISION 
NUMBER ISSUE 
DATE DATE 
INSERTED BY 
1 10/09/09 10/09/09  MJS 
2 11/11/11 11/11/11  MJS 
3 12/29/11 12/29/11  MJS 
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
 
 
 
 
 
  
 
 
 
REVISION 
NUMBER ISSUE 
DATE DATE 
INSERTED BY...

Page 3

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page iii 
 
 
 
LIST OF REVISIONS 
 
Rev Description  Date 
0  (Original Issue)   4/6/2009 
1  Added STC number, weight and balance information and minor corrections.  10/09/2009 
2  Updated part numbers, minor corrections in Chapters 0, 2, 3, 5, 6 and 7.   11/11/2011 
3  Expanded content in Chapter 6 to include installation steps.  12/29/2011 
       
 
 
 
LIST OF EFFECTIVE PAGES 
Title         Page(s) Revision No. 
Record of Revisions       i   2 
List...

Page 4

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page iii 
 
TABLE OF CONTENTS 
 
Identification  Title         Page 
CHAPTER 0  INTRODUCTION        
   1. Scope         0-1  
   2. Purpose        0-1 
   3. Arrangement        0-1 
   4. Applicability        0-1 
   5. Definitions        0-1 
   6. Abbreviations        0-1 
   7. Precautions        0-1 
   8. Units of Measurement       0-2 
      9. Information Essential to the Continued Airworthiness       0-2 
          of the Heater System 
   10....

Page 5

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page 0-1 
 
        
CHAPTER 0 
INTRODUCTION 
1. SCOPE 
 
The scope of this manual encompasses the scheduled and unscheduled maintenance procedures 
for the continued airworthiness of the Air Comm Corporation heater system installed in the Bell 429 
helicopter. 
 
2. PURPOSE 
 
The purpose of this manual is to provide the aircraft mechanic in the field the necessary information 
to maintain the heater system. 
 
3. ARRANGEMENT 
 
This manual is arranged by...

Page 6

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page 0-3 
 
 
 
 
8.  UNITS OF MEASUREMENT 
 
All measurements contained within this manual are given in the United States standard 
measurement, followed by the metric conversion in parentheses.  
  
 
9.  INFORMATION ESSENTIAL TO THE CONTINUED AIRWORTHINESS OF THE  
 HEATER SYSTEM. 
 
This manual provides information which is required for operation and maintenance of the Air Comm 
heater system installed in the Bell model 429 series helicopter. After...

Page 7

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page 0-2 
13. HEATER SYSTEM DESCRIPTION AND OPERATION 
 
The cabin heater system is a bleed air type, which incorporates the mini ejector concept as shown 
by the General Arrangement drawing (figure 3.1 and 3.2). The heater plumbing extends from the aft 
engine firewall forward across the cabin roof, and down the RH door post were it branches out under 
the pilots seats to supply heat to all the system ejectors, as well as the windshield defrosters....

Page 8

HEATER SERVICE MANUAL 429H-201M-1 
Revision 0    Page 1-1 
 
 
 
CHAPTER 1 
AIRWORTHINESS LIMITATION  
  
 
 
The Airworthiness Limitations section is FAA approved and specifies inspections and other 
maintenance required under §§43.16 and 91.403 of the Federal Aviation Regulations 
unless an alternative program has been FAA approved.   
 
 
 
 
1. AIRWORTHINESS LIMITATIONS 
 
None 
 
 
  
  
 
 
 
 
 
 
 
 
 
 
 
 
THIS AREA INTENTIONALLY LEFT BLANK 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
    
 
  

Page 9

HEATER SERVICE MANUAL 429H-201M-1 
Revision 1    Page 2-1 
CHAPTER 2 
 INSPECTIONS 
 
1. INSPECTION REQUIREMENTS 
 
 
 
 
PERIODIC INSPECTIONS 
 
NOTE 
The 429 provisions kits do not require periodic inspection until the 429 component kits have 
been installed. 
 
 
See Appendix A for a complete list of provision and component drawings. 
 
Item Annually 
Prior to Heating Season Special Inspection Information  Ref. Figure 
Heater System 
Control Valve  X  Check for ease of mechanical operation and...

Page 10

HEATER SERVICE MANUAL 429H-201M-1 
Revision 2    Page 3-2 
 
 
 
CHAPTER 3 
LOCATION AND ACCESS 
 
1.  LOCATION OF HEATER FEATURES 
 
Nomenclature  Figure  Description of Location 
Cabin Heater General Arrangement 3.1 System overview 
Cabin Heater General Arrangement 3.2 System overview 
Engine Compartment Bleed Air Plumbing  
(Engines to Firewall Shutoff Valve) 3.3 Cabin roof 
Bleed Air Plumbing – Firewall Shutoff Valve to 
Heater System Control Valve 3.4  Cabin ceiling, RH door post and floor. 
Bleed...