Page 21
HEATER SERVICE MANUAL 429H-201M-1 Revision 2 Page 3-13 Figure 3.11 Heater Control Panel (Aircraft right looking inboard)
Page 22
HEATER SERVICE MANUAL 429H-201M-1 Revision 2 Page 3-13 Figure 3.12 Heater System Electrical Schematic
Page 24
HEATER SERVICE MANUAL 429H-201M-1 Revision 2 Page 3-15 Heater System Control Valve Body (View looking aft) Heater System Control Valve Controls (View looking down) Figure 3.13 Heater System Control Valve
Page 25
HEATER SERVICE MANUAL 429H-201M-1 Revision 0 Page 4-1 CHAPTER 4 PLACARDS AND MARKINGS Figure 4.1 Placards and Markings 429H-6620-33 ES39300-14 ES39300-12
Page 26
HEATER SERVICE MANUAL 429H-201M-1 Revision 2 Page 5-1 CHAPTER 5 SERVICING 1. SERVICING INFORMATION No servicing required for the continued airworthiness of the 429 Heater System. 2. SUGGESTED SPARES LIST Item Description Part No. 1 Heater Shut Off Valve ES26192-1 2 Cockpit Heater Ejector 429H-6602-4 3 Cabin Heater Ejector Assy. FWD 429H-6610-1 Left Side 429H-6610-2 Right Side 4 Cabin Heater Ejector Assy. AFT 429H-6608-1 Right Side...
Page 27
HEATER SERVICE MANUAL 429H-201M-1 Revision 3 Page 6-1 CHAPTER 6 STANDARD PRACTICES INFORMATION 1. B-NUT / FITTING SAFETY WIRE PROCEDURE A. Use MS20995C-32 per QQ-W-423B Cond A Safety wire (or Equivalent) to secure all B-nut / Fittings in the heater bleed air system. i. Cut safety wire with excess length. ii. Thread through safety wire hole in B-nut (or fitting). iii. Pull ends even. Twist safety wire to ensure a tight fit against the safety wire hole on the B- nut (or...
Page 28
HEATER SERVICE MANUAL 429H-201M-1 Revision 3 Page 6-4 CHAPTER 6 STANDARD PRACTICES INFORMATION (cont’d) 3. REMOVAL INSTALLATION / REPLACEMENT OF THE HEATER SHUTOFF VALVE (see figure 3.3). REMOVAL A. Gain access to the Main Rotor Transmission Cowling. B. Disconnect the bleed air plumbing from the Shutoff Valve. C. Disconnect the electrical connection to the valve. D. Remove the two MS27039C-1-15 mounting screws and remove the heater shutoff valve from the aircraft....
Page 29
HEATER SERVICE MANUAL 429H-201M-1 Revision 3 Page 6-4 CHAPTER 6 STANDARD PRACTICES INFORMATION (cont’d) 5. REMOVAL INSTALLATION / REPLACEMENT OF THE HEATER THERMAL SNAP SWITCHES REMOVAL A. Remove NAS1802-3-7 Bolt, MS21043-3 Nut, NAS1149CO316R Washer (qty 2) and MS21919WCH2 clamp. B. Remove M81824/1-1(qty 2) environmental splice. C. Remove S-8016EC-1 Thermal Snap Switch INSTALLATION / REPLACEMENT NOTE Maintain a minimum clearance of 0.8 inches between Snap...
Page 30
HEATER SERVICE MANUAL 429H-201M-1 Revision 3 Page 6-4 CHAPTER 6 STANDARD PRACTICES INFORMATION (cont’d) INSTALLATION / REPLACEMENT NOTE Always use a back-up wrench to hold the union, bulkhead fitting, or component that the Bleed Air Plumbing is being connected to. A. Align connection and thread B-Nut until metal on metal contact is felt. Continue to tighten an additional 60 degrees of rotation and safety wire per step 1. B. After completion of Bleed Air Plumbing installation,...