AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 35 CHAPTER 6 STANDARD PRACTICES INFORMATION (continued) 10. REMOVAL, INSTALLATION/ REPLACEMENT OF BY-PASS VALVE ASSEMBLY. REMOVAL A. Access refrigerant plumbing to By-pass Valve. B. It will be necessary to evacuate (discharge) the refrigerant from the system to remove or replace the by-pass valve. Instructions for servicing of the system are found in Chapter 5 Servicing. CAUTION Refrigerant servicing should be...
Page 42
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 36 CHAPTER 6 STANDARD PRACTICES INFORMATION (continued) 11. REMOVAL, INSTALLATION / REPLACEMENT OF AFT EVAPORATOR BLOWER MOTOR REMOVAL CAUTION It is recommended that the battery and external power be disconnected before starting work. A. Access to the aft evaporator blower assemblies requires the removal of the overhead ceiling panel in the main cabin area. B. Remove the hardware that attaches the blower motor to...
Page 43
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 37 CHAPTER 6 STANDARD PRACTICES INFORMATION (continued) THIS PAGE INTENTINALLY LEFT BLANK FOR FURTURE USE
Page 44
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 38 CHAPTER 7 TROUBLESHOOTING 1. SYSTEM TROUBLESHOOTING Prior to troubleshooting a defective system, it is advisable to conduct a visual inspection for general condition, and obvious signs of damage or failure. The following matrix lists the easiest checks, and the most likely problems. Problem Probable Cause Solution System not Cooling (Evaporator blowers still operating) a. System is low or empty of refrigerant. a....
Page 45
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 39 CHAPTER 7 TROUBLESHOOTING (continued) 1. SYSTEM TROUBLESHOOTING (continued) Problem Probable Cause Solution System not cooling (Evaporator blowers not operating) j. Forward and aft evaporator blower motor(s) j. Check for power to the motor(s), and for the free movement of the blower wheel. If the motor shaft does not turn smoothly the motor must be replaced, as shown in chapter 6. ¹ Loss of cooling...
Page 46
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 40 CHAPTER 7 TROUBLESHOOTING (continued) Figure 7-1 General Arrangement – Air Conditioning System Installation.
Page 47
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 41 CHAPTER 7 TROUBLESHOOTING (continued) Figure 7-2 Air Conditioning System Electrical Schematic
Page 48
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 42 (S/N 001 Thru 005) CHAPTER 7 TROUBLESHOOTING (continued) Figure 7-3 Air Conditioning System Electrical Schematic (Cut and paste drawing)
Page 49
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 43 (S/N 006 thru 014) CHAPTER 7 TROUBLESHOOTING (continued) Figure 7-4 Refrigerant Plumbing Schematic
Page 50
AIR CONDITIONER SERVICE MANUAL EC145-200M-1 Revision 13 Page 44 CHAPTER 7 TROUBLESHOOTING (continued) Cut and paste Electrical Schematic with 3rd Aft Evaporator Blower (S/N 015 and Subsequent)